Sanhua SD2 series drive
User Manual v3.5 –Sep-27.2022 38
8. CERTIFICATION
This series of drives are designed and manufactured according to the following standards and certified by CE-LVD and CB
reports.
8.1 Safety standards
EN 60335-1:
Household and similar electrical appliances Safety –
Part 1:
General requirements.
EN 60335-2-34:
Household and similar electrical appliances Safety –
Part 2-34:
Particular requirements for
motor-compressors.
EN 60335-2-40:
Household and similar electrical appliances Safety –
Part 2-40:
Particular requirements for electrical
heat pumps, air-conditioners and dehumidifier.
Note:
The drive software of DSP is divided into security – related parts and function – related parts. The safety –
related parts are authenticated by CLASS B and have independent checksum.
Note:
Compressor model selection and output current protection value setting are stored in EEPROM as function –
related parts without review, so as to avoid duplicate authentication due to matching different compressors.
8.2 EMC standards
EN 55014-1:
Electromagnetic compatibility(EMC) – requirements for household appliances, electric tools and similar
apparatus –
Part 1:
Emission CE conducted margin(Conducted Emission): 3db;RE Radiations margin(radiations
emissions): 3db
EN 55014-2:
Electromagnetic compatibility (EMC) – Requirements for household appliances, electric tools and similar
apparatus – Part 2: Immunity – Product family standard
EN 61000-3-2:
Electromagnetic compatibility(EMC) –
Part 3-2:
Limits – Limits for harmonic currents produced by
equipment connected to public low – voltage systems(equipment input current≤16A per phase)
EN 61000-3-12:
Electromagnetic compatibility (EMC) –
Part 3-12:
Limits – Limits for harmonic currents produced by
equipment connected to public low – voltage systems (equipment input current > 16A and ≤75A per phase)
EN 61000-3-3:
Electromagnetic compatibility (EMC) –
Part 3-3
: Limits– Limitation of voltage changes, voltage
fluctuations and flicker in public low – voltage systems, for equipment with rated current ≤ 16A per phase and not
subject to conditional connection
EN 61000-4-2:
Electromagnetic compatibility (EMC) –
Part 4-2:
Testing and measurement techniques – Electrostatic
discharge immunity test
8KV Contact discharge, 15KV Air discharge; Criterion B Breakpoint test (all ports of client used)
4KV Contact discharge, 8KV Air discharge; Criterion B Charged test (all ports of client used)
EN 61000-4-3:
Electromagnetic compatibility (EMC) –
Part 4-3:
Testing and measurement techniques – Radiated,
radio-frequency, electromagnetic field immunity test
10V/m, 80-1000MHz; Criterion A
EN 61000-4-4:
Electromagnetic compatibility (EMC) –
Part 4-4:
Testing and measurement techniques – Electrical fast
transient / burst immunity test
2KV / 5KHz (signal Line), 4KV / 5KHz (Power Line); Criterion B
EN 61000-4-5:
Electromagnetic compatibility (EMC) –
Part 4-5:
Testing and measurement techniques – Surge
immunity test
2KV (Difference module), 4KV (Common module); Criterion B
EN 61000-4-8:
Electromagnetic compatibility (EMC) –
Part 4-5:
Testing and measurement techniques – Power
frequency magnetic field immunity test
Содержание SD2 Series
Страница 1: ... SD2 Series Drive ...