Environmental Specification
Table 6: Environmental Specifications
Temperature
Operating
0°C to 50°C ambient (32 F to 122 F)
Storage
-10°C to 60°C ambient (14 F to 140 F)
Humidity
10%-90% @ 39°C, non condensing
Altitude
Operating
Up to 3,000 m (9,900 ft.)
Storage
Up to 5,000 m (16,500 ft.)
FlatView HYG is intended for indoor use only. To avoid product damage do not use in a
sheltered outdoor, outdoor or sunlit environment.
Observe that the product is not exposed to direct sunlight (UV radiation):
•
Prolonged exposure shortens field life and voids the warranty
•
Short exposure may lead to higher temperatures inside the product and cause
permanent damage
•
Direct exposure accelerates long-term aging
For intend use in an outdoor environment or a sunlit environment, contact your Kontron
representative.
6.5.
Certification
The FlatView HYG complies with the following standards.
Table 7: Certification
CE Marking
CE, cULus with CB report (pending)
Safety
EN 62368-1 (pending)
EMC
EN55032 Class B
Shock (IEC 60068-2-27)
Operating Shock: 15 G, 11 ms duration, half-sinus
Storage Shock: 30 G, 11 ms duration, half-sinus
Vibration (IEC 60068-2-6)
Operating Vibration: 5 – 500 Hz: 1.0 G/3axis
Storage Vibration: 5 – 500 Hz: 2.0 G/3axis
Low Voltage Directive (Electrical Safety)
2014/35/EU
RoHS II Directive
2011/65/EU
WEEE Directive
2002/19/EC
MTBF
> 50000 h
IP Protection Class
VESA: IP 67 / DIN EN 60529
Support Arm: IP69K (ISO 20653)
Содержание kontron FlatView HYG
Страница 1: ... USER GUIDE www kontron com 1 FlatView HYG Doc User Guide Rev 1 0 Doc ID 1067 7845 ...
Страница 2: ...FlatView HYG User Guide Rev 1 0 www kontron com 2 This page has been intentionally left blank ...
Страница 24: ...FlatView HYG User Guide Rev 1 0 www kontron com 24 8 Mechanical Diagrams 8 1 21 5 Support Arm ...
Страница 25: ...FlatView HYG User Guide Rev 1 0 www kontron com 25 8 2 21 5 VESA M12 ...