Sandstrom SWC32B11 Скачать руководство пользователя страница 26

 

26 

lubricant, clogging in the lubricant oil line, or intermittent lubricant oil supply. Dirt and other 
impurities in the lubricant oil will increase its viscosity and cause the shaft to be seized. 
Copper plating may also result in seizing of shaft. 
b) Seizing of piston 
This is caused by too small fit clearance between the piston and cylinder or expansion due 
to heat. Judgement of seizing shaft and piston: After the refrigerator has been powered on, 
the compressor will not start and run, but a slight hum sound can be heard, and several 
seconds later, thermal protective relay will actuate and make the contacts open; this 
process will occur repeatedly, but the compressor cannot be started. 
E. Compressor won't stop 
Sometimes, the compressor will run continuously(for several hours or run without end), If 
the food placed in the refrigerator is not too much, there may be the following two situations: 
i) the refrigerator very low, this means that the control system is probably out of order; ii) 
the control system works normally, and there are troubles in the refrigerating system or 
other parts. 
1) Temperature is set improperly 
a) The temperature control knob is set to the "coldest" position. This position is to be used 
for fast freezing or continuous running, its temperature for power off is too low, therefore, 
the compressor won't stop and the temperature in the refrigerator becomes lower and 
lower . 
b) Inspection method: check the temperature control knob to see whether it is set in the 
position "coldest". 
2) Thermostat is malfunctioning and makes the compressor running continuously 
Analysis of Trouble 
When the thermostat doesn't work normally, it will make the compressor run continuously, 
and hence very low temperature will be achieved in the refrigerator. The fault is generally 
due to the fact that the contacts of the thermostat cannot be released. 
Remedy 
Dismantle the thermostat and make a through checkup, if it is totally out of functioning, 
replace it with a new one. 
3) evaporation temperature is too high in refrigerating system, resulting in lower 
refrigerating capacity and hence continuous running of compressor 
Analysis of Trouble 
Leakage of refrigerant and clogging in a refrigerating system will directly affect its 
refrigerating capacity. Due to the reduction in its refrigerating capacity, the refrigerator 
temperature cannot reach its rated value, the thermostat won't work, thus the compressor 
runs continuously. When the evaporation temperature in the system is too high, the 
temperature sensing agent in the temperature sensor is also hotter, therefore, the 
thermostat is unable to cut off the power supply to the compressor and stop it. 
Remedy 
If it has been found that the refrigerant in the system is insufficient in quantity, recharge it 
with refrigerant. In case clogging occurs, disassemble the part where it is blocked. If the 
evaporation temperature is too high, settle this problem with an appropriate quantity of 
refrigerant. 

Содержание SWC32B11

Страница 1: ...1 WINE COOLER Service Manual Models SWC32B11 Features Energy efficiency Low noise operation Thick insulation for energy efficiency...

Страница 2: ...ct code illumination and Series Introduction 2 3 Specifications 3 4 Safety precautions 4 5 Function Schedule 7 6 System Flow Chart 8 7 Circuit Diagram 9 8 Maintenance Service and Trouble Shooting 10 9...

Страница 3: ...Net capacity L 108 Color black Power Supply V Hz 220 50 Rated Input Power W Power Consumption kW h 24h Net Weight kg 31 Gross Weight kg 34 Unit Dimension D W H mm 510 500 845 Packing Dimension D W H...

Страница 4: ...cur if voltage is outside the range 187 242V unless a regulator with a capacity of 750W or higher is installed It is required to use separate special outlet with securely grounding The power cable of...

Страница 5: ...ce personnel When there is leakage of inflammable gas Never try to pull out or insert any power plug for any electrical appliance such as refrigerator Electricity plug must be cut off for below follow...

Страница 6: ...rowaves on top of the refrigerator Do not use electric appliances except those allowed by manufacturer in side the refrigerator Do not play by hanging on its door to prevent tilting the door or toppli...

Страница 7: ...ance It is strictly prohibited to privately dismantle or change the appliance component For the repair of refrigerator it can be carried out by professional only Do not put the bottled beer or beverag...

Страница 8: ...8 Function Schedule Function Schedule Energy efficiency Low noise operation Thick insulation for energy efficiency...

Страница 9: ...ow Chart 1 Compressor 2 Condenser 3 Dry filter 4 Capillary tube 5 Evaporator 2 Brief Description of System Flow Chart Model SWC32B11 is a direct cooling single system refrigerator When the refrigerato...

Страница 10: ...m 2 Brief Description of Control Principle Model SWC32B11 is a direct cooling single system larder A mechanical type of all the control is generally adopted The thermostat directly controls the start...

Страница 11: ...t true No cooling If compressor can run after it stop to run five minutes and give power Check and repair according to the section of the compressor does not work If compressor can run naturally and t...

Страница 12: ...ing Is cooling capacity insufficient Check and repair according to the section of Cooling capacity is insufficient 1 The thermostat was set at the coldest position 2 The ambient temperature is very hi...

Страница 13: ...3 Cooling capacity is insufficient YES NO YES YES NO YES Cooling capacity is insufficient Adjust and instruct consumer how to use Repair Is the ambient temperature low than 16 C Does the refrigerant...

Страница 14: ...ior light on when door is opened Is the power of 220V output Do the compressor have 220V output Check and repair compressor and accessory Is the ambient temperature low than 16 C Check the power sourc...

Страница 15: ...se the pressure difference is still greater after the compressor has just stopped running the refrigerant will flow for a certain time therefore this sound is a normal phenomenon 2 A click sound can o...

Страница 16: ...correctly locate them and take reasonable remedy measures based on their comprehensive analysis of trouble characteristics as well as operating conditions for various kinds of refrigerators Three Esse...

Страница 17: ...h and feel the condenser the temperature of its upper part should be higher than that of its lower part or its right part is hotter than its left part depending on the type of condenser coil this indi...

Страница 18: ...ressure in the system is usually lower than the saturation pressure corresponding to the same ambient temperature Remedy In case there is leakage of refrigerant from the system do not hurry to recharg...

Страница 19: ...evacuate it and then recharge the system with refrigerant 4 Low efficiency of compressor Analysis of Trouble Low efficiency of a refrigerating compressor refers to the actual reduction of gas discharg...

Страница 20: ...or inlet to wash it several times then purge and dry it with nitrogen 7 Flowing obstructed in refrigerating system Analysis of Trouble Because the refrigerating system was originally not purged thorou...

Страница 21: ...d sometimes cannot the refrigerator compartment works normally at the beginning but after working for a certain period of time frosting begins at the clogged position evaporation temperature reaches b...

Страница 22: ...lysis of Trouble The compressor works by means of the opening and closing of gas suction valve and discharge valve to suck and discharge the refrigerant If the valve block is broken the refrigerant ca...

Страница 23: ...tive relay actuate and bring to a stoppage Remedy Check up how the air has been left in the refrigerating system Generally there are two possibilities one is that the air has been sucked into the syst...

Страница 24: ...ower supply to see whether it is connected to the compressor circuit Analysis of Trouble In case the compressor cannot be started this will generally exhibit in the power supply circuit for instance p...

Страница 25: ...s have been burned or short circuited between turns the fuse will be blown repeatedly and the blowout occurs particularly at the instant when you close the knife switch Remedy Check the terminals and...

Страница 26: ...comes lower and lower b Inspection method check the temperature control knob to see whether it is set in the position coldest 2 Thermostat is malfunctioning and makes the compressor running continuous...

Страница 27: ...ous 3 Electric leakage test a Slight electric leakage A tingle sense will be experienced as soon as you touch the metal parts of the refrigerator with your hand When you test them with a test pencil i...

Страница 28: ...of tubes or the loosening of parts may cause vibration and noise 4 Inspection method To find the sources of noise press the vibration spot with your hand while the refrigerator is in operation and li...

Страница 29: ...29...

Страница 30: ...30...

Страница 31: ...31...

Отзывы: