background image

 

17 

spring inside the compressor has broken . 
During the normal operation of compressor ,a slight and uniform hum sound due to 
undulation of electric current can be heard generally ,this is a normal 
phenomenon .However ,if it sounds like "tong ,tong 

",i.e., an impact sound inside the 

compressor ,this means that a large quantity of wet vapour of refrigerant or refrigerating oil 
has come into the compressor cylinder ;if it sounds like "dang ,dang

", a striking sound of 

metal parts inside the compressor ,this means that some moving parts have loosened 
(note to differentiate this sound from those formed during starting or stopping the 
compressor). 
b) Listen to the sound caused by the flowing of gas in the evaporator. Open the refrigerator 
door while the compressor is in operation ,incline your ear and listen attentively the gas 
flow sound inside the evaporator .If it sounds like gentle whistling accompanied by a sound 
similar to water flowing ,this is the sound produced by the normal circulation of refrigerant 
within the evaporator .In case only the gas flowing sound can be heard and there is no 
water flowing sound ,this indicates that the refrigerant has already percolated .If neither the 
flowing sound nor the gas sounds from the evaporator can be heard ,this means that the 
filter or capillary has been clogged . 

3)Touch and Feel 

a) Feel the compressor when running ,its temperature should be generally less than 90

°

in the normal state (it may exceed 90

°

C in case of running for a longer period of time ). 

b) After the compressor has operated normally for 5~10 minutes , touch and feel the 
condenser ,the temperature of its upper part should be higher than that of its lower part (or 
its right part is hotter than its left part ,depending on the type of condenser coil ),this 
indicates that the refrigerant is circulating . If the condenser is not hot ,this means the 
leakage of refrigerant .In case the condenser radiates heat for only several minutes and 
then cools down ,this means that the filter and capillary have been clogged .As for the 
forced air cooling condenser ,hot air will be blown out of it ;this means that the system is 
out of order . 
c) Feel the filter's temperature .During the normal operation of refrigerating system ,the 
temperature on the filter's surface should be a little higher than the ambient temperature ;if 
you touch it with your hand ,you will have a sense of slight heat .In case dew condensation 
appears due to the fact that its temperature is obviously lower than the ambient 
temperature ,this means that most meshes of its screen has been clogged ,resulting in an 
obstructed flowing of refrigerant ,thus causing a drop in temperature due to throttling . 
d) Feel the temperature of exhaust gas from the refrigerating system .the exhaust gas 
should be very hot and this is the normal working state .For those refrigerator with 
enclosed type of compressor refrigerating system, no frost or dew drop will from on the gas 
suction tube ,otherwise ,there is something wrong in the system (Frosting and dew 
condensation may appear for a very short time period when just starting the machine ,this 
is a normal phenomenon ). Because a refrigerator is a combination of several 
components ,they are related and have influence on each other In case an abnormal 
phenomenon has been found through the above-mentioned checkups ,you need not to 

Содержание SWC32B11

Страница 1: ...1 WINE COOLER Service Manual Models SWC32B11 Features Energy efficiency Low noise operation Thick insulation for energy efficiency...

Страница 2: ...ct code illumination and Series Introduction 2 3 Specifications 3 4 Safety precautions 4 5 Function Schedule 7 6 System Flow Chart 8 7 Circuit Diagram 9 8 Maintenance Service and Trouble Shooting 10 9...

Страница 3: ...Net capacity L 108 Color black Power Supply V Hz 220 50 Rated Input Power W Power Consumption kW h 24h Net Weight kg 31 Gross Weight kg 34 Unit Dimension D W H mm 510 500 845 Packing Dimension D W H...

Страница 4: ...cur if voltage is outside the range 187 242V unless a regulator with a capacity of 750W or higher is installed It is required to use separate special outlet with securely grounding The power cable of...

Страница 5: ...ce personnel When there is leakage of inflammable gas Never try to pull out or insert any power plug for any electrical appliance such as refrigerator Electricity plug must be cut off for below follow...

Страница 6: ...rowaves on top of the refrigerator Do not use electric appliances except those allowed by manufacturer in side the refrigerator Do not play by hanging on its door to prevent tilting the door or toppli...

Страница 7: ...ance It is strictly prohibited to privately dismantle or change the appliance component For the repair of refrigerator it can be carried out by professional only Do not put the bottled beer or beverag...

Страница 8: ...8 Function Schedule Function Schedule Energy efficiency Low noise operation Thick insulation for energy efficiency...

Страница 9: ...ow Chart 1 Compressor 2 Condenser 3 Dry filter 4 Capillary tube 5 Evaporator 2 Brief Description of System Flow Chart Model SWC32B11 is a direct cooling single system refrigerator When the refrigerato...

Страница 10: ...m 2 Brief Description of Control Principle Model SWC32B11 is a direct cooling single system larder A mechanical type of all the control is generally adopted The thermostat directly controls the start...

Страница 11: ...t true No cooling If compressor can run after it stop to run five minutes and give power Check and repair according to the section of the compressor does not work If compressor can run naturally and t...

Страница 12: ...ing Is cooling capacity insufficient Check and repair according to the section of Cooling capacity is insufficient 1 The thermostat was set at the coldest position 2 The ambient temperature is very hi...

Страница 13: ...3 Cooling capacity is insufficient YES NO YES YES NO YES Cooling capacity is insufficient Adjust and instruct consumer how to use Repair Is the ambient temperature low than 16 C Does the refrigerant...

Страница 14: ...ior light on when door is opened Is the power of 220V output Do the compressor have 220V output Check and repair compressor and accessory Is the ambient temperature low than 16 C Check the power sourc...

Страница 15: ...se the pressure difference is still greater after the compressor has just stopped running the refrigerant will flow for a certain time therefore this sound is a normal phenomenon 2 A click sound can o...

Страница 16: ...correctly locate them and take reasonable remedy measures based on their comprehensive analysis of trouble characteristics as well as operating conditions for various kinds of refrigerators Three Esse...

Страница 17: ...h and feel the condenser the temperature of its upper part should be higher than that of its lower part or its right part is hotter than its left part depending on the type of condenser coil this indi...

Страница 18: ...ressure in the system is usually lower than the saturation pressure corresponding to the same ambient temperature Remedy In case there is leakage of refrigerant from the system do not hurry to recharg...

Страница 19: ...evacuate it and then recharge the system with refrigerant 4 Low efficiency of compressor Analysis of Trouble Low efficiency of a refrigerating compressor refers to the actual reduction of gas discharg...

Страница 20: ...or inlet to wash it several times then purge and dry it with nitrogen 7 Flowing obstructed in refrigerating system Analysis of Trouble Because the refrigerating system was originally not purged thorou...

Страница 21: ...d sometimes cannot the refrigerator compartment works normally at the beginning but after working for a certain period of time frosting begins at the clogged position evaporation temperature reaches b...

Страница 22: ...lysis of Trouble The compressor works by means of the opening and closing of gas suction valve and discharge valve to suck and discharge the refrigerant If the valve block is broken the refrigerant ca...

Страница 23: ...tive relay actuate and bring to a stoppage Remedy Check up how the air has been left in the refrigerating system Generally there are two possibilities one is that the air has been sucked into the syst...

Страница 24: ...ower supply to see whether it is connected to the compressor circuit Analysis of Trouble In case the compressor cannot be started this will generally exhibit in the power supply circuit for instance p...

Страница 25: ...s have been burned or short circuited between turns the fuse will be blown repeatedly and the blowout occurs particularly at the instant when you close the knife switch Remedy Check the terminals and...

Страница 26: ...comes lower and lower b Inspection method check the temperature control knob to see whether it is set in the position coldest 2 Thermostat is malfunctioning and makes the compressor running continuous...

Страница 27: ...ous 3 Electric leakage test a Slight electric leakage A tingle sense will be experienced as soon as you touch the metal parts of the refrigerator with your hand When you test them with a test pencil i...

Страница 28: ...of tubes or the loosening of parts may cause vibration and noise 4 Inspection method To find the sources of noise press the vibration spot with your hand while the refrigerator is in operation and li...

Страница 29: ...29...