u1fmdl1sm-rev0814
Model U1F UL79 Listed Metallic Design Level 1 Page 22
Grounding The Pump
This 8 foot long (244 centimeters) Ground Strap (Item 32) is
shipped with the eyelet end fastened to the pump hardware.
To reduce the risk of static electrical sparking, this pump
must be grounded. Check the local electrical code for
detailed grounding instruction and the type of equipment
required, or in the absence of local codes, an industry or
nationally recognized code having jurisdiction over specific
installations and installation codes.
Take action to prevent static
sparking. Fire or explosion
can result, especially when
handling flammable liquids.
The pump, piping, valves, con-
tainers or other miscellaneous
equipment must be grounded.
WARNING
One eyelet is installed to a true earth ground. (Requires a 5/16 or 8mm maximum diameter bolt)