background image

s15nmdl3sm-rev0316

sandpiperpump

.

com

Model S15 Non-Metallic • 

6

Recommended Installation Guide

Troubleshooting Guide

For additional troubleshooting tips contact After Sales Support at [email protected] or 419-524-8388

Symptom:

Potential Cause(s):

Recommendation(s):

Pump Cycles Once

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Air valve or intermediate gaskets installed incorrectly. Install gaskets with holes properly aligned.
Bent or missing actuator plunger.

Remove pilot valve and inspect actuator plungers.

Pump Will Not Operate 

/ Cycle

Pump is over lubricated.

Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.

Lack of air (line size, PSI, CFM).

Check the air line size and length, compressor capacity (HP vs. CFM required).

Check air distribution system.

Disassemble and inspect main air distribution valve, pilot valve and pilot valve actuators. 

Discharge line is blocked or clogged manifolds.

Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping.

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Blocked air exhaust muffler.

Remove muffler screen, clean or de-ice, and re-install. 

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Pump chamber is blocked.

Disassemble and inspect wetted chambers. Remove or flush any obstructions. 

Pump Cycles and Will 

Not Prime or No Flow

Cavitation on suction side.

Check suction condition (move pump closer to product).

Check valve obstructed. Valve ball(s) not seating 

properly or sticking.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket.  

Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. 

Use heavier valve ball material.

Valve ball(s) missing (pushed into chamber or 

manifold).

Worn valve ball or valve seat. Worn fingers in valve ball cage (replace part). Check Chemical 

 

Resistance Guide for compatibility.

Valve ball(s) / seat(s) damaged or attacked by product.

Check Chemical Resistance Guide for compatibility.

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary. 

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or strainers.

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Pump Cycles Running 

 

Sluggish / Stalling,

 

Flow Unsatisfactory

Over lubrication.

Set lubricator on lowest possible setting or remove. Units are designed for lube free operation.

Icing.

Remove muffler screen, de-ice, and re-install. Install a point of use air drier. 

Clogged manifolds.

Clean manifolds to allow proper air flow.

Deadhead (system pressure meets or exceeds air 

supply pressure).

Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. 

 

(Does not apply to high pressure 2:1 units).

Cavitation on suction side.

Check suction (move pump closer to product).

Lack of air (line size, PSI, CFM).

Check the air line size, length, compressor capacity.

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Air supply pressure or volume exceeds system hd.

Decrease inlet air (press. and vol.) to the pump. Pump is cavitating the fluid by fast cycling. 

Undersized suction line.

Meet or exceed pump connections. 

Restrictive or undersized air line.

Install a larger air line and connection. 

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Suction line is blocked.

Remove or flush obstruction. Check and clear all suction screens or strainers.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. 

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. 

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary.

Entrained air or vapor lock in chamber(s).

Purge chambers through tapped chamber vent plugs. Purging the chambers of air can be dangerous. 

Product Leaking 

Through Exhaust

Diaphragm failure, or diaphragm plates loose.

Replace diaphragms, check for damage and ensure diaphragm plates are tight.

Diaphragm stretched around center hole or bolt holes. Check for excessive inlet pressure or air pressure. Consult Chemical Resistance Chart for compatibility 

with products, cleaners, temperature limitations and lubrication.

Premature Diaphragm 

Failure

Cavitation.

Enlarge pipe diameter on suction side of pump.

Excessive flooded suction pressure.

Move pump closer to product. Raise pump/place pump on top of tank to reduce inlet pressure.

 

Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener.

Misapplication (chemical/physical incompatibility).

Consult Chemical Resistance Chart for compatibility with products, cleaners, temperature limitations 

and lubrication.

Incorrect diaphragm plates or plates on backwards, 

installed incorrectly or worn.

Check Operating Manual to check for correct part and installation. Ensure outer plates have not been 

worn to a sharp edge.

Unbalanced Cycling 

Excessive suction lift.

For lifts exceeding 20’ of liquid, filling the chambers with liquid will prime the pump in most cases.

Undersized suction line.

Meet or exceed pump connections.

Pumped fluid in air exhaust muffler.

Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly.

Suction side air leakage or air in product.

Visually inspect all suction-side gaskets and pipe connections.

Check valve obstructed.

Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. 

Check valve and/or seat is worn or needs adjusting.

Inspect check valves and seats for wear and proper setting. Replace if necessary. 

Entrained air or vapor lock in chamber(s).

Purge chambers through tapped chamber vent plugs. 

UNIVERSAL ALL SANDPIPER, EXCEPT FLAP

2: INST

AL

 & OP

Содержание S15 Non-Metallic

Страница 1: ...Certified Certified Quality Warren Rupp Inc A Unit of IDEX Corporation 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2016 Warren Rupp Inc...

Страница 2: ...g the internal portions of the pump i e dry running For further guidance on ATEX applications please consult the factory When the pump is used for materials that tend to settle out or solidify the pum...

Страница 3: ...SECTION 4 AIR END 10 Air Distribution Valve Assembly Air Valve with Stroke Indicator Assembly Pilot Valve Assembly Intermediate Assembly SECTION 5 WET END 16 Diaphragm Drawings Diaphragm Servicing SE...

Страница 4: ...h 220VAC Coil E7 Solenoid Kit with 220VAC Explosion Proof Coil E8 Solenoid Kit with 110VAC 50 Hz Explosion Proof Coil E9 Solenoid Kit with 230VAC 50 Hz Explosion Proof Coil SP Stroke Indicator Pins A1...

Страница 5: ...sistance 250 F 121 C 0 F 18 C Santoprene Injection molded thermoplastic elastomer with no fabric layer Long mechanical flex life Excellent abrasion resistance 275 F 135 C 40 F 40 C UHMW PE A thermopla...

Страница 6: ...E AIR INLET 3 4 NPT Note Porting Flanges are also available with PN10 40mm DIN bolting configuration STANDARD ENCAPSULATED MUFFLER 1 NPT EXHAUST PORT FOR OPTIONAL MUFFLER STYLES OR PIPING EXHAUST AIR...

Страница 7: ...ide check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically...

Страница 8: ...ir causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut o...

Страница 9: ...point of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is des...

Страница 10: ...End Kit Nitrile Diaphragms Nitrile Balls and PTFE Seals 476 255 365 Wetted End Kit Neoprene Diaphragms Neoprene Balls and PTFE Seals 476 255 633 Wetted End Kit FKM Diaphragms PTFE Balls and PTFE Seal...

Страница 11: ...3 8 4 901 048 308 Washer Flat 3 8 4 NOT SHOWN 535 010 000 Muffler 1 530 027 000 Muffler 1 530 033 000 Muffler 1 Item Part Number Description Qty 1 031 140 000 Air Valve Assembly 1 031 140 001 Air Val...

Страница 12: ...ed GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 408 Cork and Neoprene 4...

Страница 13: ...52 518 198 552E Manifold 40mm DIN 2 replaces 518 197 552E item 23 43 538 022 110 Nipple Pipe 4 538 022 308 Nipple Pipe 4 44 560 078 611 O Ring 8 45 618 003 110 Plug Pipe 4 618 003 308 Plug Pipe 4 46 6...

Страница 14: ...1 NOTE Thespillcontainmentoptionhastwoadditional pumping diaphragms item 41 PTFE Pumping diaphragms are installed with the natural concave curve toward the outer chamber NOTE One Piece Diaphragm Servi...

Страница 15: ...115 Screw Self tapping 4 For Pumps with Metal Mesh Muffler or Piped Exhaust 1 031 141 001 Air Valve Assembly 1 Includes all items used on 031 140 001 minus items 1 D 1 F 1 J Air Distribution Valve Se...

Страница 16: ...mbly 1 1 J 710 015 308 Screw Self Tapping 4 includes all other items on 031 146 000 above For Pumps with Piped Exhaust 1 031 147 000 Air Valve Assembly 1 includes all items on 031 146 000 minus 1 D 1...

Страница 17: ...m sleeve 2 B inspect O Rings 2E replace if required Step 4 Lightly lubricate O Rings 2 C and 2 E Reassemble in reverse order 2 A 2 B 2 C 2 F 2 E 2 D Pilot Valve Assembly Parts List Item Part Number De...

Страница 18: ...ermediate Assembly Drawing Step 1 Remove plunger actuator 28 from center of intermediate pilot valve cavity Step 2 Remove Ring Retaining 30 discard Step 3 Remove bushing plunger 6 inspect for wear and...

Страница 19: ...Service Drawing Non Overlay Diaphragm Service Drawing with Overlay Torque 480 in lbs Field conversion kit 475 256 000 available for conversion from PTFE Overlay to One Piece bonded Diaphragm Part Desc...

Страница 20: ...bly together Torque values are called out on the exploded view Repeat procedure for second side assembly Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensat...

Страница 21: ...se link shall be as high as or higher than the maximum expected short circuit current at the location of the installation usually 1500 A A maximum permissible ripple of 20 is valid for all magnets of...

Страница 22: ...manifolds from the pump The discharge elbows can be rotated in 90 increments and the suction elbows can be rotated in 180 increments see optional positioning in the Dual Porting Drawing SINGLE PORTIN...

Страница 23: ...0Hz or 220 240VAC 50 60Hz Kit 032 045 000 12 32VDC To install electronic leak detectors remove the bottom NPT pipe plug on the visual sight tube item 49 Insert leak detector into the pipe tee item 48...

Страница 24: ...irective 2006 42 EC on Machinery according to Annex VIII This product has used Harmonized Standard EN809 1998 A1 2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance...

Страница 25: ...chnical knowledge apply to the listed equipment AODD Pumps and Surge Suppressors Technical File No 203104000 1410 MER AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps...

Отзывы: