Sandpiper DRILLERS DMF3S Скачать руководство пользователя страница 9

dmf3sdl7sm-rev0317 

Model DMF3S Page 7

TROUBLE SHOOTING

PROBLEM:

 Pump cycles but will not pump. (Note: higher suction lifts require faster 

cycling speed for priming.)

POSSIBLE CAUSES:

A. Air leak in suction line.

B. Excessive suction lift. 

C. Check valve not closing. 

D. Leakage at joint of suction manifold or elbow flange. 

E. Suction line plugged. 

F. Diaphragm ruptured.

PROBLEM:

 Pump will not cycle. (Note: Always disconnect air supply to relieve air 

pressure before disassembling any portion of pump.)

POSSIBLE CAUSES:

A. Discharge hose or line plugged, or discharge head requirement greater than air 

pressure. (Disconnect discharge line to check.)

B. Spool in air distribution valve not shifting. (Remove end cap and check spool - must 

slide freely.)

C. Diaphragm ruptured. (Air will escape out discharge line in this case.)

D. Blockage in diaphragm chamber preventing movement. (Shut off air supply and 

reopen after pressure is relieved.)

E. Plugged or dirty exhaust muffler.

PROBLEM:

 Uneven discharge flow. (Indicates one chamber not operating properly.)

POSSIBLE CAUSES:

A. Check valve not sealing properly in one chamber.

B. Diaphragm failure in one chamber.

C. Air leak at suction manifold joint or elbow flange one side.

For additional information, see the Warren Rupp Troubleshooting Guide.

WARRANTY

This pump is warranted for a period of five years against defective material and 

workmanship. Failure to comply with the recommendations stated in this manual voids 

all factory warranty.

RECOMMENDED WARREN RUPP ACCESSORIES 

TO MAXIMIZE PUMP PERFORMANCE:

• Tranquiilizer

® 

Surge Suppressor. For nearly pulse-free flow.

•  Warren Rupp Air Dryer. For clean, dry compressed air.
•  Warren Rupp Filter/Regulator. For modular installation and 

service convenience.

•  Warren Rupp Speed Control. For manual or programmable 

process control. Manual adjustment or 4-20mA reception.

For more detailed information on these accessories, contact your local 

Warren Rupp Factory-Authorized Distributor, or Warren Rupp corporate 

headquarters.

Содержание DRILLERS DMF3S

Страница 1: ...tion and Start Up 4 Air Supply 4 Air Inlet Priming 4 ESADS Plus Externally Serviceable Air Distribution System 5 Pilot Valve 6 Pilot Valve Actuator 6 Air Exhaust 6 Between Uses 6 Check Valve Servicing...

Страница 2: ...uld be flushed after each use to prevent damage In freezing temperatures the pump should be completely drained between uses Before pump operation inspect all fasteners for loosening caused by gasket c...

Страница 3: ...umps are designed to be powered only by compressed air 10 0 20 30 40 50 60 70 80 90 20 0 40 60 80 100 120 140 160 180 200 220 240 260 20 34 40 68 60 101 9 80 135 9 100 169 9 100 PSI 80 PSI 60 PSI 40 P...

Страница 4: ...S SS PS B B A B 245 MATERIALS OF CONSTRUCTION To order a pump or replacement parts first enter the Model Number DMF3S followed by the Type Designation listed below in the far left column Materials Ope...

Страница 5: ...sions DMF3S Dimensions are 1 8 Figures in parenthesis millimeters 5 7 3 5 9 4 3 0 3 1 7 7 0 5 8 1 0 7 4 5 7 3 5 9 4 8 8 4 2 2 3 8 9 1 4 0 5 9 0 4 3 6 6 8 2 7 6 3 3 3 9 1 NPT AIR INLET 3 NPT DISCHARGE...

Страница 6: ...ely pressurizes one side of the air distribution valve spool while exhausting the other side The pilot valve is shifted at each end of the diaphragm stroke by the diaphragm plate coming in contact wit...

Страница 7: ...x head capscrews each end on the end caps of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and must move freel...

Страница 8: ...idity conditions Use of a Warren Rupp Extractor Dryer unit should eliminate most icing problems BETWEEN USES When used for materials that tend to settle out or transform to solid form the pump should...

Страница 9: ...ter pressure is relieved E Plugged or dirty exhaust muffler PROBLEM Uneven discharge flow Indicates one chamber not operating properly POSSIBLE CAUSES A Check valve not sealing properly in one chamber...

Страница 10: ...Nitrile Rubber Color coded RED 361 Nitrile 363 FKM Fluorocarbon Color coded YELLOW 364 E P D M Rubber Color coded BLUE 365 Neoprene Rubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM...

Страница 11: ...EW HEX HEAD 1 2 13 UNC X 2 00 8 14 170 023 330 CAPSCREW HEX HEAD 4 15 170 024 330 CAPSCREW HEX HD 7 16 14 X 1 8 16 170 032 330 CAPSCREW HEX HEAD 8 17 170 034 330 CAPSCREW HEX HEAD 1 2 13 UNC X 2 00 8...

Страница 12: ...56 PLATE OUTER DIAPHRAGM 2 46 618 003 330 PLUG PIPE 1 4 2 47 618 004 330 PIPE PLUG 2 48 620 011 114 PLUNGER ACTUATOR 2 49 670 006 115 RETAINER FLAP VALVE 4 50 685 008 120 ROD DIAPHRAGM 1 51 720 004 36...

Страница 13: ...d tradenames of Warren Rupp Inc Printed in U S A 34 23 22 24 31 21 32 5 A 5 D 33 4 18 5 F 5 E 50 11 39 48 15 36 30 37 55 49 42 52 29 54 52 53 27 35 25 26 58 19 2 7 17 56 36 5 B 5 C 16 12 9 60 44 61 38...

Страница 14: ...98 A1 2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Страница 15: ...knowledge apply to the listed equipment AODD Pumps and Surge Suppressors Technical File No 203104000 1410 MER AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09A...