Sandpiper DRILLERS DMF3S Скачать руководство пользователя страница 6

dmf3sdl7sm-rev0317 

Model DFM3S Page 4

PLEASE NOTE! 

The photos shown in this manual are for general instruction only. Your specific model 

may not be shown. Always refer to the parts list and exploded view drawing for your 

specific model when installing, disassembling or servicing your pump.

PRINCIPLE OF PUMP OPERATION

This  flap  swing  check  valve  pump  is  powered  by  compressed  air  and  is  a  1:1 

pressure ratio design. It alternately pressurizes the inner side of one diaphragm 

chamber, while simultaneously exhausting the other inner chamber. This causes the 

diaphragms, which are connected by a common rod, to move endwise. Air pressure 

is applied over the entire surface of the diaphragm, while liquid is discharged from 

the opposite side. The diaphragm operates under a balanced condition during the 

discharge stroke, which allows the unit to be operated at discharge heads over 200 

feet (61 meters) of water head.

Since the diaphragms are connected by a common rod, secured by plates to the 

center of the diaphragms, one diaphragm performs the discharge stroke, while the 

other is pulled to perform the suction stroke in the opposite chamber.

For maximum diaphragm life, keep the pump as close to the liquid being pumped 

as possible. Positive suction head in excess of 10 feet of liquid (3.048 meters) may 

require a back pressure regulating device. This will maximize diaphragm life.

Alternate pressuring and exhausting of the diaphragm chamber is performed by 

means of an externally mounted, pilot operated, four-way spool type air distribution 

valve. When the spool shifts to one end of the valve body, inlet air pressure is applied 

to one diaphragm chamber and the other diaphragm chamber exhausts. When the 

spool shifts to the opposite end of the valve body, the porting of chambers is reversed. 

The air distribution valve spool is moved by an internal pilot valve which alternately 

pressurizes one side of the air distribution valve spool, while exhausting the other side. 

The pilot valve is shifted at each end of the diaphragm stroke by the diaphragm plate 

coming in contact with the end of the pilot valve spool. This pushes it into position for 

shifting of the air distribution valve.

The chambers are manifolded together with a suction and discharge check valve 

for each chamber, maintaining flow in one direction through the pump.

INSTALLATION & START-UP

Locate the pump as close to the product being pumped as possible, keeping suction 

line length and number of fittings to a minimum. Do not reduce line size.

For installations of rigid piping, short flexible sections of hose should be installed 

between pump and piping. This reduces vibration and strain to the piping system. 

A Warren Rupp Tranquilizer

®

 Surge Suppressor is recommended to further reduce 

pulsation in flow.

This pump was tested at the factory prior to shipment and is ready for operation. It is 

completely self-priming from a dry start for suction lifts of 20 feet (6.096 meters) or less. 

For suction lifts exceeding 20 feet of liquid, fill the chambers with liquid prior to priming.

AIR SUPPLY

Air supply pressures cannot exceed 125 psi (8.61 bar). Connect the pump air inlet 

to an air supply of sufficient capacity and pressure required for desired performance. 

When the air line is solid piping, use a short length of flexible hose (not less than 3/4" 

(19mm) in diameter) between pump and piping to eliminate strain to pipes.

AIR INLET & PRIMING

For start-up, open an air valve approximately 1/2" to 3/4" turn. After the unit primes, 

an air valve can be opened to increase flow as desired. If opening the valve increases 

cycling rate, but does not increase flow rate, cavitation has occurred, and the valve 

should be closed slightly.

For the most efficient use of compressed air and the longest diaphragm life, throttle 

the air inlet to the lowest cycling rate that does not reduce flow.

SERVICE AND OPERATING MANUAL

Model DMF3S 

Type 7 

II 2GD T5

See pages 15 & 16 

for ATEX ratings

DR  LLERS

S E R I E S

Содержание DRILLERS DMF3S

Страница 1: ...tion and Start Up 4 Air Supply 4 Air Inlet Priming 4 ESADS Plus Externally Serviceable Air Distribution System 5 Pilot Valve 6 Pilot Valve Actuator 6 Air Exhaust 6 Between Uses 6 Check Valve Servicing...

Страница 2: ...uld be flushed after each use to prevent damage In freezing temperatures the pump should be completely drained between uses Before pump operation inspect all fasteners for loosening caused by gasket c...

Страница 3: ...umps are designed to be powered only by compressed air 10 0 20 30 40 50 60 70 80 90 20 0 40 60 80 100 120 140 160 180 200 220 240 260 20 34 40 68 60 101 9 80 135 9 100 169 9 100 PSI 80 PSI 60 PSI 40 P...

Страница 4: ...S SS PS B B A B 245 MATERIALS OF CONSTRUCTION To order a pump or replacement parts first enter the Model Number DMF3S followed by the Type Designation listed below in the far left column Materials Ope...

Страница 5: ...sions DMF3S Dimensions are 1 8 Figures in parenthesis millimeters 5 7 3 5 9 4 3 0 3 1 7 7 0 5 8 1 0 7 4 5 7 3 5 9 4 8 8 4 2 2 3 8 9 1 4 0 5 9 0 4 3 6 6 8 2 7 6 3 3 3 9 1 NPT AIR INLET 3 NPT DISCHARGE...

Страница 6: ...ely pressurizes one side of the air distribution valve spool while exhausting the other side The pilot valve is shifted at each end of the diaphragm stroke by the diaphragm plate coming in contact wit...

Страница 7: ...x head capscrews each end on the end caps of the valve body assembly With the end caps removed slide the spool back and forth in the sleeve The spool is closely sized to the sleeve and must move freel...

Страница 8: ...idity conditions Use of a Warren Rupp Extractor Dryer unit should eliminate most icing problems BETWEEN USES When used for materials that tend to settle out or transform to solid form the pump should...

Страница 9: ...ter pressure is relieved E Plugged or dirty exhaust muffler PROBLEM Uneven discharge flow Indicates one chamber not operating properly POSSIBLE CAUSES A Check valve not sealing properly in one chamber...

Страница 10: ...Nitrile Rubber Color coded RED 361 Nitrile 363 FKM Fluorocarbon Color coded YELLOW 364 E P D M Rubber Color coded BLUE 365 Neoprene Rubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM...

Страница 11: ...EW HEX HEAD 1 2 13 UNC X 2 00 8 14 170 023 330 CAPSCREW HEX HEAD 4 15 170 024 330 CAPSCREW HEX HD 7 16 14 X 1 8 16 170 032 330 CAPSCREW HEX HEAD 8 17 170 034 330 CAPSCREW HEX HEAD 1 2 13 UNC X 2 00 8...

Страница 12: ...56 PLATE OUTER DIAPHRAGM 2 46 618 003 330 PLUG PIPE 1 4 2 47 618 004 330 PIPE PLUG 2 48 620 011 114 PLUNGER ACTUATOR 2 49 670 006 115 RETAINER FLAP VALVE 4 50 685 008 120 ROD DIAPHRAGM 1 51 720 004 36...

Страница 13: ...d tradenames of Warren Rupp Inc Printed in U S A 34 23 22 24 31 21 32 5 A 5 D 33 4 18 5 F 5 E 50 11 39 48 15 36 30 37 55 49 42 52 29 54 52 53 27 35 25 26 58 19 2 7 17 56 36 5 B 5 C 16 12 9 60 44 61 38...

Страница 14: ...98 A1 2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that...

Страница 15: ...knowledge apply to the listed equipment AODD Pumps and Surge Suppressors Technical File No 203104000 1410 MER AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09A...

Отзывы: