ENGLISH
13
8. Do not install the device immediately underneath a power soc-
ket.
9. For fixed electrical installation, disconnection means should
be included in accordance with installation regulations, with
contact separation at all poles that provides total disconnec-
tion under Category III overvoltage conditions.
10. This heater is Class II (double-insulated ) and therefore does
not require an earth connection.
11. The safety zones required by the local electrical installation
standards or safety regulations applicable in your country must
be strictly observed. In any case, if it is going to be installed in
a bathroom, NEVER install it in the area indicated as AREA 0,
AREA 1 or AREA 2. As it is an IP21 rated device, it can be ins-
talled in AREA 3, provided it is placed so that it is NOT in reach
of anybody who is in the bathtub or shower, this including the
device’s power cord. (See FIGURE 3).
12.
CAUTION: Some parts of this device may get very hot and
cause severe burns. Special care must be taken when children
and vulnerable persons are present.
13. Before plugging in the device, make sure the mains voltage
matches that indicated on the data plate.
14. If the power cord is damaged, it should be replaced at one of
our official S&P Service Centers or by a qualified professional.
15.
To avoid overheating, DO NOT COVER the device.
16. Do not insert any rigid body through the bars, this could dama-
ge the device, start a fire or cause electric shock.
17. In humid rooms, the power cord must be at least 25 cm above
the ground. Make sure the cord doesn’t touch the ground.
18. Make sure the power cord doesn’t touch the hottest parts of
the device.
19. Children under 3 years old should be kept out of the reach of
the appliance unless they are continuously supervised.
20. Children under 8 years old may NOT operate the appliance.
Содержание PM-1005
Страница 1: ...PM 755 PM 1005 PM 1505 PM 2005 ...
Страница 2: ...2 ...