KIT EDM-100 S 12V + CT-12/14 

For this model use the following wiring 
diagram: 
Fig.7. To switch the fan through the 
safety isolating transformer CT-12/14. 

EDM-100 C, CH and CHR 

Models fi 

tted with thermo-electric 

automatic shutter. 

WARNING: The opening of the shutter 
is facilitated by means of a thermal 
system that requires a few seconds 
to open completely. 

KIT EDM-100 C 12V + CT-12/14 

Fig. 6. To switch the fan through the 
safety isolating transformer CT-12/14. 

KIT EDM-100 S 12V + CT-12/14R 
KIT EDM-100 C 12V + CT-12/14R 

These models are provided with a 
safety isolating transformer fi tted  with 
an adjustable over-run timer. The timer 
allows the fan to continue to operate for 
the selected period after the switch has 
been switched off. 
Fig. 7 shows how to connect the fan 
with a timer through the safety isolating 
transformer CT-12/14R and the 
possibility of using the same switch as 
for the lighting circuit. 
The desired run-on time is selected by 
means of an adjuster positioned on the 
printed circuit board of the CT-12/14R. 

EDM-100 H, CH and CHR 

Models provided with an integral humidity 
sensor, which can be adjusted from 60-
90% RH by the rotary switch on the front 
of the fan without removing the grille. The 
controller is factory set to approx. 72% 
RH. They are fi tted with a pullcord switch 
(IC) enabling override of the fan when 
the relative humidity level in the room is 
lower than the set % RH value. 

A variable % RH rotary switch on the 
connection cover (3) of the fan can be 
adjusted: 
- To lower the RH, turn the adjuster 

towards the minus sign. The fan 
will operate more frequently, as the 
controller will be more sensitive. 

- To increase the RH, turn the adjuster 

towards the plus sign. The fan 
will operate less frequently, as the 
controller will be less sensitive. 

KIT EDM-100 H 12V + CT-12/14 (Fig. 8)

Automatic operation with pull cord 
switch enabling override of the fan when 
the relative humidity level in the room is 
lower than the set % RH value. 

KIT EDM-100 CH 12V + CT-12/14 (Fig. 8) 

Fitted with thermo-electric shutter and 
pull cord switch enabling override of 
the fan when the relative humidity level 
in the room is lower than the set % RH 
value. 

KIT EDM-100 CHR 12V + CT-12/14H 

This model is similar to EDM-100 
CH and provided with an adjustable 
over-run timer and humidistat. The 
extractor will stop automatically when 
the humidity drops below the selected 
level and after the selected period set 
on the timer. 
Fig. 9 shows how to connect the fan 
with a timer through the safety isolating 
transformer CT-12/14H and the 
possibility of using the same switch as 
for the lighting circuit. 
The desired run-on time is selected by 
means of an adjuster “T” positioned on 
the printed circuit board (Fig.10). 

CLEANING AND MAINTENANCE
IMPORTANT:

 DISCONNECT FROM THE 

MAINS SUPPLY BEFORE CARRYING 

Содержание KIT EDM-100 12V+CT-12/14

Страница 1: ...KIT EDM 100 12V CT 12 14 ...

Страница 2: ...Fig 3 Fig 2 Fig 1 Fig 4 Fig 10 ...

Страница 3: ...Fig 5 ...

Страница 4: ...N 230 V 50Hz 12 V 50Hz L 12 VAC 14VA MAX FUSE 100 mA MAX TIME DELAY CT 12 14 N L KIT EDM 100 S 12V CT 12 14 KIT EDM 100 C 12V CT 12 14 Fig 6 ...

Страница 5: ...KIT EDM 100 C 12V CT 12 14R FUSE 100 mA MAX TIME DELAY N L 12 VAC 14VA MAX CT 12 14 R N L 12 V 230 V 50Hz 50Hz N L LS 1 30 Fig 7 ...

Страница 6: ...CT 12 14 N 230 V 50Hz 12 V 50Hz L 12 VAC 14VA MAX FUSE 100 mA MAX TIME DELAY KIT EDM 100 H 12V CT 12 14 KIT EDM 100 CH 12V CT 12 14 N L Fig 8 ...

Страница 7: ...CT 12 14 H 12 V 230 V 50Hz 50Hz FUSE 100 mA MAX TIME DELAY N L LS LS 12 VAC 14VA MAX N L N L Fig 9 KIT EDM 100 CHR 12V CT 12 14H ...

Страница 8: ...ivalent standards for your country The final installation should be examined and tested by a competent person This fan is IPX4 rated and can be installed within reach of a person using a fixed bath or shower however the fan must not be placed where it can be submerged in water Do not install near sources of heat in excess of 40 C This appliance is not intended for use by young children or infirm p...

Страница 9: ... ring Cut a 105mm diameter hole in glass Loosen the screws on the front and back protections grilles 1 and 10 Loosen the threaded ring 9 and remove the 4 spacers 8 Mount the fan depending on the installation requirements so that the glass is between the two rubber joints 7 Fig 5a All the spacers on the outside Fig 5b All the spacers on the inside Fig 5c Spacers on the outside and the inside For do...

Страница 10: ...switch IC enabling override of the fan when the relative humidity level in the room is lower than the set RH value A variable RH rotary switch on the connection cover 3 of the fan can be adjusted To lower the RH turn the adjuster towards the minus sign The fan will operate more frequently as the controller will be more sensitive To increase the RH turn the adjuster towards the plus sign The fan wi...

Страница 11: ... guarantee If you detect any fault contact your S P dealer All S P products are designed to be recycled when they reach the end of their working life to save the environment and to reduce landfill GUARANTEE The EDM 100 12V products are covered by a two year guarantee subject to the specified maintenance stated within this booklet In the event of any failure of the extract fan within two years of s...

Страница 12: ...ía ir su mergido dentro del agua El extractor no debe instalarse cerca de una fuente de calor superior a 40ºC Este aparato no está destinado al uso por niños o personas enfermas salvo que estén adecuadamente supervi sadas por una persona responsable para asegurar que utilizan el aparato de forma segura Los niños pequeños deben ser supervisados para asegu rar que no juegan con el aparato INSTALACIO...

Страница 13: ...0 Desenroscar en el anillo roscado 9 y sacar los 4 separadores 8 Montar el EDM según sus necesida des colocando el cristal o tabique en tre las dos juntas de goma 7 Fig 5a Todos los separadores en el exterior Fig 5b Todos los separadores en el interior Fig 5c Separadores distribuidos interior y exterior Cuando el aparato se instala en cristal doble o tabique puede que no necesi te utilizar todos l...

Страница 14: ...s inferior al valor ajustado El ajuste se efectúa por medio de la rue da selectora que se halla en la tapa de protección 3 Para disminuir la consigna de húmeda relativa girar el potenciómetro hacia el signo La sensibilidad será más alta por lo cual el extractor funcionará mas a menudo Para aumentar la consigna de húmeda relativa girar el potenciómetro hacia el signo La sensibilidad será más baja p...

Страница 15: ...s donde será debidamente atendido Cualquier manipulación efectuada en el aparato por personas ajenas a los Ser vicios Oficiales de S P nos obligaría a cancelar su garantía RECICLAJE La normativa de la CEE y el compromi so que debemos adquirir con las futuras generaciones nos obligan al reciclado de materiales le rogamos que no olvide depositar todos los elementos sobran tes del embalaje en los cor...

Страница 16: ...aérateur ne doit pas être installé proche d une source de chaleur supérieure à 40ºC Cet appareil n est pas conçu pour être utilisé par des enfants ou des personnes malades sauf s ils sont surveillés par une personne responsable afin d assurer qu ils utilisent le produit en toute sécurité Les jeunes enfants doivent être surveillés pour s assurer qu ils ne jouent pas avec le produit INSTALLATION Ava...

Страница 17: ...gue de serrage 9 et retirer les 4 éléments séparateurs 8 Monter l EDM selon la configuration désirée en prenant soin de placer la vitre ou paroi entre les deux joints caoutchouc 7 Fig 5a Séparateurs à l extérieur Fig 5b Séparateurs à l intérieur Fig 5c Séparateurs répartis de part et d autre de la vitre Si la vitre ou cloison est épaisse il se peutquetouslesélémentsséparateurs ne soient pas nécess...

Страница 18: ... équipés d un interrupteur à cordelette permettant de mettre en marche l extracteur quand le niveau d humidité dans la pièce est inférieur à la valeur préréglée Le réglage s effectue à l aide du bouton moleté placé sur le couvercle de protection 3 Pour diminuer la consigne d humidité relative tourner le potentiomètre vers le signe La sensibilité sera plus grande et donc l aérateur fonctionnera plu...

Страница 19: ...ent entraîner la suppression de la garantie En cas de problème avec l extracteur se mettre en contact avec son distributeur RECYCLAGE La norme de la CEE et l engagement que nous devons prendre par rapport aux nouvelles générations nous obligent à recycler les matériaux nous vous prions donc de ne pas oublier de déposer tous les éléments restants de l emballage dans les containers de recyclage corr...

Страница 20: ...0800 Soler Palau Sistemas de Ventilación S L U C Llevant 4 08150 Parets del Vallès Barcelona ESPAÑA Tel 93 571 93 00 Fax 93 571 93 01 Fax int 34 93 571 93 11 e mail consultas solerpalau com Web www solerpalau com ...

Отзывы: