background image

 
 

360 Herndon Parkway 

 Suite 

1400 

 

Herndon, VA 20170 

 http://www.rheintech.com 

 

SanDisk Corporation 

 

 

 

 

 

 

 

 

           Page 6 of 17 

DoC Report 
2006137 
02/02/07 

2.4  EQUIPMENT UNDER TEST 

Listed below are the identifiers and descriptions of all equipment, cables, and internal devices used with the EUT for this test. 
 

 

Equipment Under Test 

Part 

Manufacturer 

Model 

Serial 

Number 

FCC 

ID 

Cable 

Description 

RTL 

Bar 

Code 

Equipment 

Arrival 

Date 

ATA Storage 
Device 

SanDisk 
Corporation 

SanDisk SSD 
UATA 5000 1.8” 

6C3C213 DoC 

Internal 

017740 

01/08/2007 

 
Auxiliary Equipment 

Part 

Manufacturer 

Model 

Serial 

Number 

FCC 

ID 

Cable 

Description 

RTL 

Bar 

Code 

Equipment 

Arrival 

Date 

Laptop PC 

Dell 

Latitude 
D420PP09S 

CND3520M69 DoC 

Unshielded 
Power 

017739 01/08/2007 

Laptop AC Adapter 

Dell 

LA65NS0-00 

CN-0DF263-
71615682-
2ED4 

N/A Unshielded 

017737 

01/08/2007 

DVD Player 

Dell 

PD01S 

CN-OUC793-
42940-68P-
0053 

DoC Shielded 

017738 

01/08/2007 

Speaker harman/kardon 

Multimedia 
Speaker System 

CN-02320V-
47781-07J-
0888 

N/A Unshielded 

012542 

09/22/2000 

USB Termination 

Gateway, Inc. 

USB PCB 

Rev 1.0 

N/A 

Shielded 

008645 

04/07/1997 

Microphone Gateway, 

Inc. 

Telex 

700358 

N/A 

Unshielded 

016989 

01/24/2006 

Ethernet hub 

Flowpoint 

134 

F258219 

Class 

Device 

Unshielded 
Power 

901278 10/04/2002 

Содержание SSD UATA 5000

Страница 1: ...orporation 7 Atir Yeda Street Kfar Saba Israel Phone 972 9 7644908 Device Under Test SanDisk SSD UATA 5000 1 8 Document Number 2006137 Reference Number QRTL06 334 This report may not be reproduced except in full without the written approval of Rhein Tech Laboratories Inc ...

Страница 2: ...g FCC Class B Compliance Standard s to which device was tested STANDARDS SPECIFIC TESTS APPLICABILITY Tested Not Tested CFR47 Parts 15 109 and 15 107 Radiated and Conducted Emissions Test Engineer Jon Wilson Signature Report Written By Jon Wilson Signature Report Approved By Desmond Fraser Signature Report Number 2006137 Report Date February 2 2007 Accredited by the National Voluntary Accreditatio...

Страница 3: ...FIGURATION OF TESTED SYSTEM 7 3 PRODUCT LABELLING INFORMATION TO THE USER 8 3 1 DOC LABEL ON DEVICE 8 3 2 DOC STATEMENT IN USER S MANUAL 8 3 3 LOCATION OF LABEL ON EUT 8 4 CONDUCTED EMISSIONS 9 4 1 SITE AND TEST DESCRIPTION 9 4 2 CONDUCTED EMISSIONS TEST DATA 10 4 3 CONDUCTED TEST PHOTOGRAPHS 11 5 RADIATED EMISSIONS 12 5 1 SITE AND TEST DESCRIPTION 12 5 2 FIELD STRENGTH CALCULATION 13 5 3 RADIATED...

Страница 4: ...ite 1400 Herndon Va 20170 Complete description and site attenuation measurement data has been placed on file with the Federal Communications Commission The power line conducted emission measurements were performed in a shielded enclosure also located at the Herndon Virginia facility Rhein Tech Laboratories is accepted by the FCC as a facility available to do measurement work for others on a contra...

Страница 5: ...n RDT per Weibull method o Operating shock 1 500G 0 5msec half sine o Operating vibration 2 17G 7 800 Hz o Operating temperature 0 C to 70 C o Non operating temperature and storage 55 C to 95 C 2 2 MODIFICATIONS None 2 3 EUT EXERCISE DESCRIPTION The SanDisk SSD UATA 5000 1 8 was installed in a Class B laptop personal computer which was running Windows XP The computer was programmed to transfer fil...

Страница 6: ...7 Auxiliary Equipment Part Manufacturer Model Serial Number FCC ID Cable Description RTL Bar Code Equipment Arrival Date Laptop PC Dell Latitude D420PP09S CND3520M69 DoC Unshielded Power 017739 01 08 2007 Laptop AC Adapter Dell LA65NS0 00 CN 0DF263 71615682 2ED4 N A Unshielded 017737 01 08 2007 DVD Player Dell PD01S CN OUC793 42940 68P 0053 DoC Shielded 017738 01 08 2007 Speaker harman kardon Mult...

Страница 7: ...e 1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 7 of 17 DoC Report 2006137 02 02 07 2 5 CONFIGURATION OF TESTED SYSTEM USB Termination DVD Player Speaker Microphone Laptop PC with SanDisk SSD UATA 5000 ...

Страница 8: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a part...

Страница 9: ...ane and electrically connected to the peripheral LISN powers the EUT host peripherals The spectrum analyzer was connected to the A C line through an isolation transformer The 50 ohm output of the EUT LISN was connected to the spectrum analyzer input through a Solar 7 kHz high pass filter The filter is used to prevent overload of the spectrum analyzer from noise below 7 kHz Conducted emission level...

Страница 10: ...0 7 34 0 56 0 22 0 46 0 12 0 Pass 3 950 Pk 34 2 1 1 35 3 56 0 20 7 46 0 10 7 Pass 17 670 Pk 25 1 2 5 27 6 60 0 32 4 50 0 22 4 Pass Phase Conductor Temperature 74 F Humidity 40 Emission Frequency MHz T e s t Detector Analyzer Reading dBuV S i t e Correction Factor dB Emission Level dBuV CISPR B QP Limit dBuV CISPR B QP Margin dBuV CISPR B AV Limit dBuV CISPR B AV Margin dBuV Pass Fail 0 157 Pk 46 9...

Страница 11: ...360 Herndon Parkway Suite 1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 11 of 17 DoC Report 2006137 02 02 07 4 3 CONDUCTED TEST PHOTOGRAPHS ...

Страница 12: ...uency the EUT was rotated 360 and the antenna was raised and lowered from 1 to 4 meters in order to determine the emission s maximum level Measurements were taken using both horizontal and vertical antenna polarizations For frequencies between 30 and 1000 MHz the spectrum analyzer s 6 dB bandwidth was set to 120 kHz and the analyzer was operated in the CISPR quasi peak detection mode For emissions...

Страница 13: ...Correction Factor SCF used in the above equation is determined empirically and is expressed in the following equation SCF dB m PG dB AF dB m CL dB SCF Site Correction Factor PG Pre amplifier Gain AF Antenna Factor CL Cable Loss The field intensity in microvolts per meter can then be determined according to the following equation FI uV m 10 FI dBuV m 20 For example assume a signal at a frequency of...

Страница 14: ... Qp V 220 1 0 36 8 16 0 20 8 30 0 9 2 Pass 167 988 Qp V 300 1 4 39 1 16 1 23 0 30 0 7 0 Pass 191 990 Qp V 145 1 0 42 1 16 4 25 7 30 0 4 3 Pass 211 994 Qp V 330 1 0 32 6 16 1 16 5 30 0 13 5 Pass 249 994 Qp V 160 1 0 40 9 12 2 28 7 37 0 8 3 Pass 335 985 Qp V 190 1 0 37 3 9 4 27 9 37 0 9 1 Pass 365 785 Qp V 280 1 0 35 3 8 3 27 0 37 0 10 0 Pass 479 989 Qp H 269 2 2 36 4 4 6 31 8 37 0 5 2 Pass Note The...

Страница 15: ...360 Herndon Parkway Suite 1400 Herndon VA 20170 http www rheintech com SanDisk Corporation Page 15 of 17 DoC Report 2006137 02 02 07 5 4 RADIATED TEST PHOTOGRAPHS ...

Страница 16: ...ster Rev 14 0 2 N A N A Radiated Emissions RF Preselector for HP 8566B or 8568B 20Hz 2GHz Hewlett Packard 85685A 3146A01309 900889 4 12 2007 Spectrum Analyzer 100Hz 15GHz Hewlett Packard 8567A 2727A00535 900897 3 3 2007 Spectrum Analyzer Display Section Hewlett Packard 85662A 2816A16471 900896 3 3 2007 Quasi Peak Adapter Hewlett Packard 52022 910E 119044 189 900099 3 7 2007 Amplifier RTL PR 1040 1...

Страница 17: ...ng the measurement procedure and test equipment that was used contained in the test report iv A description of the equipment under test EUT and support equipment connected to or installed within the EUT v The identification of the EUT and support equipment by trade name and model number and if appropriate by FCC identifier and serial number vi The types and lengths of connecting cables used and ho...

Отзывы: