7.0   Machine Parts List

Drawing No.

Part No.

Item Description

Quantity

1

SN-12-ST-RED

12-Gallon Solution Tank - Red

1

2

10-0479

1/4" Male Close Nipple

2

3

10-0845

1/4" Strainer for Extractor

1

4

SN-12-L-RED

12-Gallon Lid - Red

1

5

80-0001

Extractor Exhaust Hose

0.4

6

10-0843

3/8" Black Hose for Extractor

7

7

10-0826

3/4" Hose Clamp for Extractor

6

8

80-0026

3/8 Barb x 1/4 MPT 90 Degree

1

9

10-0806

1-1/2" Grey Hose Barb Fitting for Extractor

1

10

80-0022-A

Screw for 500psi Panel

4

11

10-0204

Motor Mount Back-Up Washer

11

12

10-0803

Splashproof Switch for Extractor

3

13

10-0803-H

Heated Splashproof Switch for Extractor

1

14

80-0013

Switch Plate

1

15

80-0200

Extractor Wire Harness

1

16

SN-12-RT-BLK

12-Gallon Recovery Tank - Black

1

17

80-0008

1.5 PVC Female Adapter

1

18

10-0416-A

1-1/2" Black ABS Stand Pipe

1.3

19

10-0804-A

Hatch Cover Gasket for Extractor

1

20

10-0804

Hatch Cover for Extractor

1

21

10-0419

Screw for Extractor Hatch

12

22

80-0012

Shut-off Assembly

1

23

10-0805

Dump Valve for Extractor

1

24

80-0003-A

1-1/2" Black Lined Gray Hose

2

25

10-0849

1-1/2" ABS Fitting

1

26

10-0848-B

1-1/2" 90 Degree ABS Street Elbow

2

27

10-0810

3-Stage Extractor Motor

1

28

10-0838

Pigtail for Extractor (Pigtail Cord only - No Strain 

Relief, Nut or connectors)

1

29

10-0850

Strain Relief for Extractor

1

30

10-0851

Strain Relief Nut for Extractor

1

31

10-0822

Exhaust Grate for Extractor

3

32

10-1030-S3

3-Stage Extractor Motor Gasket

1

33

SN-12-MFLD

Extractor Motor Manifold - Black

1

34

10-0023

Shoulder & Waist Belt Washer

2

35

10-0833-L

Motor Manifold Bolt for Extractor 10-32 x 1/4" 

Hex Socket Head Cap Screw Stainless Steel

3

35

10-0833

MotorManifold Bolts for Extractor

2

36

10-0830

Hinge Keeper for Extractor

2

37

10-0821

Extractor Hinge

2

38

10-0820

End Cap for Rod on Extractor

4

39

SN-12-MB-BLK

12 Gal. Motor Base Black

1

40

10-0836

19" Axle for Extractor

1

41

10-0807

Wheels for Extractor

2

42

10-0840

Nylon Washer for Extractor Axle

8

43

10-0835-N

Nut for Pump Bolt on Extractor

4

44

10-0834

Pump Flat Washer

18

45

10-0808

Caster for Extractor

2

46

10-0816

Caster Bolt 1/4-20 x 1/2 Hex Bolt

8

47

10-0400-C

Latch for Extractor

1

48

10-0379

8-32 x 3/8 Screw

8

49

80-0040

3000psi Hose for Inside Extractor

4.75

3.0   Set-Up / Prepare Unit for Use

DO NOT USE ON WET SURFACES. DO NOT EXPOSE TO RAIN. STORE 
INDOORS.

•  All Carpet Extractors, no matter what the time of year, are shipped with antifreeze in 

the solution lines. Prior to first use, fill the tank with one quart of warm water. Attach 

the hose and using the hand tool wand, flush out the system by spraying the one quart 

of water through the pump.

•  Attach the 1-1/2 inch vacuum hose and the brass quick disconnect.
•  Fill the base unit (the recovery tank must be removed) with warm water (less than 

100 degrees Fahrenheit). Fill to approximately 4 inches from the top. Use a liquid 

detergent made for carpet cleaning or upholstery. Read and mix to the dilution ratios 

as directed.

•  Be sure to replace any filters back into the machine prior to use.
•  Do not use citrus acid, buterol or harsh degreasers inside the machine.

Electrical

Plug cord(s) into 20 AMP grounded wall outlet(s). 20 AMP circuits are normally found in 

kitchens and bathrooms. Never remove ground prong from the plug. If a circuit breaker 

trips during operation, turn machine off, reset the breaker and move the electrical cord to 

a different outlet and resume operation.

Vacuum System

The extractor uses a single vacuum motor system that provides outstanding water lift and 

air flow. 
Automatic Vacuum Shut-Off: The float assembly shut-off, located in the recovery tank on 

the vacuum stand pipe, prevents the waste tank from overflowing into the stand pipe and 

damaging the vacuum motor. The float assembly will cut-off vacuum to the waste tank. 

When this happens, immediately turn off the vacuum motor and empty the waste tank.
It is also necessary to use low foaming chemicals or defoamer to eliminate foam buildup 

in the recovery tank and damage to the vacuum motor. If moisture does enter the vacuum 

motor, it is necessary to WD-40 the motor. Remove the float assembly from the stand 

pipe and turn on both vacuum motor. Spray a five second burst of WD-40 into the stand 

pipe and continue to let the vacuum motor run for three minutes.

4.0   Maintenance

Regular maintenance is required to keep your carpet extractor in proper working 

condition. Thoroughly clean all equipment and accessories after each use:
•  Rinse the solution and recovery tanks with clean water.
•  Flush the pump system with clean water, including all hoses and wand(s).
•  Do not allow water to remain in the tanks after use.
•  Lubricate all quick disconnects with WD-40 or similar lubricant.
•  Clean vacuum shut-off assembly screen.

Содержание 80-4000-H

Страница 1: ...rants the motor and pump to be free from defects in material and workmanship under normal use and service for two 2 years All electrical parts are warranted for one 1 year Parts replaced or repaired u...

Страница 2: ...chase of your 12 Gallon Indy Automotive Carpet Extractor with Heat The world of carpet cleaning is becoming more high tech and competitive and we strive to provide you with the most innovative product...

Страница 3: ...information Model No Serial No Distributor Name Distributor Phone No Date of Purchase 12 Gallon Indry Extractor with heat By Sandia Products Table of Contents Warranty Policy 4 RMA Procedure 5 1 0 Sa...

Страница 4: ...ust contact the manufacturer to follow correct RMA warranty procedures They must have a copy of the RMA Sheet enclosed in the box with the returned item No returns shall be authorized unless the prope...

Страница 5: ...AND THE LIMITATIONS OF THIS EQUIPMENT BEFORE USE Reduce the Risk of Fire Electric Shock or Injury Use only as described in this manual Use only the attachments recommended by the manufacturer Test all...

Страница 6: ...IC SHOCK Electrical equipment must be grounded If the machine should malfunction or breakdown grounding provides a path of least resistance for electrical current to reduce the risk of electric shock...

Страница 7: ...or Inside Extractor 4 75 3 0 Set Up Prepare Unit for Use DO NOT USE ON WET SURFACES DO NOT EXPOSE TO RAIN STORE INDOORS All Carpet Extractors no matter what the time of year are shipped with antifreez...

Страница 8: ...with Water 3 Tap Float to Unstick then Clean 4 Attach or Replace 5 Close Valve 6 Replace Gasket 7 Clear Debris 8 Clean 9 Clean and Dry Area Patch with Silicone 10 Use a Low Foaming Detergent Electrica...

Отзывы: