SA 3, SA 15, SA 24, SR263, SR 343, SR 623
Environmental Qualification Form
Page 7
305147-00
NOMENCLATURE:
MARC70 RELAY, DIODE ISOLATOR,INVERTER AND REGULATOR UNIT
TYPE/MODEL/PART NO:
MARC70/SA3, SA15, SA54, SR263, SR343, SR623
TSO NUMBER:
DO160Env. Cat.E1-BBA[(SBL09U)]XXXXXXZZAZZULXXX
MANUFACTURER’S SPECIFICATION AND/OR OTHER APPLICABLE SPECIFICATIONS:
MARC70 INSTALLATION MANUAL 305147-00
ENVIRONMENTAL TEST PLAN SR343, SR263, SR623, SA24, SA15, SA3 Doc # MK700020
MANUFACTURER: SANDIA AEROSPACE
ADDRESS: 3700 OSUNA RD NE, STE 711, ALBUQUERQUE, NM 87109
REVISION & CHANGE NUMBER OF DO-160:
REV D. DATED JULY 27, 1997
CONDITION
SECTION
DESCRIPTION OF TESTS CONDUCTED
Temperature and Altitude
Low Temperature
High Temperature
In-flight Loss of Cooling
Altitude
Decompression
Overpressure
4.0
4.5.1
4.5.2 & 4.5.3
4.54
4.6.1
4.6.2
4.6.3
Equipment tested to category E1
Tested to +70oC Operating High Temperature
Tested to +85oC Ground Survival
Test not Applicable
70,000 feet
Test not Applicable
Test not Applicable
Temperature Variation
5.0
Tested to Category B
Humidity
6.0
Tested to Category B
Operational Shock and Crash Safety
7.0
Tested to Category A, Aircraft Type 5. Random Orientation
Vibration
8.0
Tested to Category S, Aircraft Zone 2 using vibration curves B and
M.
Tested to Category U, Helicopter Zone 2 using vibration curves F and
F1.
Explosion
9.0
Equipment identified as Category X, no test performed
Waterproofness
10.0
Tested to Category X, no test performed
Fluids Susceptibility
11.0
Equipment identified as Category X, no test performed
Sand and Dust
12.0
Equipment identified as Category X, no test performed
Fungus
13.0
Equipment identified as Category X, no test performed
Salt Spray
14.0
Equipment identified as Category X, no test performed
Magnetic Effect
15.0
Equipment is Category Z
Power Input
16.0
Tested to Category Z
Voltage Spike
17.0
Tested to Category A
Audio Frequency Susceptibility
18.0
Tested to Category Z
Induced Signal Susceptibility
19.0
Tested to Category Z
Radio Frequency Susceptibility
20.0
Tested to Category U
Radio Frequency Emission
21.0
Tested to Category L
Lightning Induced Transient
Susceptibility
22.0
Tested to Category X, no test performed
Lightning Direct Effects
23.00
Equipment identified as Category X, no test performed
Icing
24.0
Equipment identified as Category X, no test performed
Electrostatic Discharge
25.0
Equipment identified as Category X, no test performed
Содержание SA 3/L/NVG
Страница 12: ...Page 11 3 2 1 SRU 1 Outline Dimensions Figure 3 1 SRU 1 Outline Dimensions ...
Страница 18: ...Figure 3 4 SA 3 SA 3L Schematic and Pinout Page 17 ...
Страница 19: ...Figure 3 5 SA 3 NVG Schematic and Pinout Page 18 ...
Страница 20: ...305147 00 Figure 3 6 SA 15 Invertor Module Rev A Page 19 ...
Страница 21: ...Figure 3 7 SA 24 Diode Isolation Test Module Page 20 ...
Страница 23: ...Page 22 Figure 3 9 SR 54 20 Pole Switching Module ...
Страница 25: ...Figure 3 11 SR 343 12 Pole Switching Module Page 24 ...
Страница 26: ...305147 00 Figure 3 12 SR 623 12 Switching Module Page 25 ...