3.4
Calibration Procedures
3.4.1
SA 3
1.
With the SA 3/SA3 3L removed from the enclosure, connect the mating connector.
2.
Apply power to the SA 3/SA3 3L by activating the system which is being annunciated
by the SA 3/SA3 3L.
3..
With the annunciator dimming switch in the bright position, adjust R9 to the desired
brightness.
4.
Place the annunciator dimming switch in the dim or low position, and adjust R8 to the
desired brightness.
5.
Press the annunciator test button and ensure that all annunciators illuminate to their
maximum adjusted brightness.
R8 Dim Adujust
R9 Bright Adjust
Figure 3-13
SA 3 / SA 3LAdjustment Locations