Disturbances
Failure
air supply
The air supply amount is less than 50 l/h. The device shuts down to prevent overheating when
there is not sufficient air supplied. Disconnect the power connection cable. Check the air tubes
towards leaks, congestion and broken tubes, clean and repair if necessary.
Failure
temperature
Cause of overheating: Insufficient surrounding fresh air (example: a closed technical closet) leads
to less air flowing through the device during a maximum performance setting. The Ozonizer will
start up automatically after cooling down.
Failure
high voltage
The
operation
can be disturbed by water or dirt that has seeped into the Ozone generator. Pull
the power cable, blow pressed air through the Ozone generator to get rid of water, clean as
described above. Should the disturbance continue after cleaning, send the Ozonizer in for an
official check-up.