Electrical connections 

  Electrical installation should be done only by a licensed electrician who carries out 

the work according to the relevant regulations for electrical safety and wiring. 

  Follow the wiring rules for the breaker rating and the thickness of the electrical 

wiring. 

  Verify that the tank unit is full of water and the water stop cocks are open before 

turning on the power. 

System operation outline continuous power  

  The system runs its water heating cycle once a day to fill up the storage tank unit with 

heated water. 

  If  the block out time function is selected ( setting is covered in page 17 of Installation 

Manual ) the unit will not operate during the block out times – this function is typically 
used on installations that have time of use electricity tariffs  

  The water heating cycle operation starts automatically when the residual hot water in 

the tank unit becomes less than 150 litres. 

  The system will not run if the electrical power supply is cut off (i.e. if it is connected to 

off-peak power). However, the system will automatically start operation, once the 
electricity becomes available. 

System operation if connected to off-peak electricity 

  There are no special settings for the off-peak connection. The system will run once the 

power becomes available and the temperature in the tank drops below the set point of 
the tank thermistor. If connecting the unit to off-peak, ensure that the off-peak tariff 
provides a minimum of 5 hours continuous power, as it can take at least four hours to 
fill the tank unit with hot water if the ambient temperature is lower than 10

o

C, this can 

be longer. 

  If the unit is connected to off-peak and consumption has been higher than normal hot 

water might not be available until the next power supply cycle.  

 

Daily frequency and amount of hot water consumption may also affect the duration of 
the heating cycle operation.

 

Select the electrical supply mode that best suits the customer’s hot water 
consumption. The type of off-peak connection may need to be changed if hot water 
supply is not maintained as required. 
 
Figure 5: Outline of electrical system connections 

           

Caution 
Use Copper wiring

 

Содержание GAUS-160EQTB

Страница 1: ...AUS 160EQTB Heat Pump Unit GS3 45HPA AU This appliance is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless t...

Страница 2: ...S This water heater may be protected by one or more patents or registered designs in the name of Sanden Australia Pty Ltd TRADE MARKS Registered trademark of Sanden Australia Pty Ltd Note Every care h...

Страница 3: ...s currently available It s even more efficient when connected to off peak power and the noise level is so low it will operate unobtrusively throughout the night How it works The Heat Pump Water Heater...

Страница 4: ...Sanden Heat Pump Owner s Manual Page 4 of 20...

Страница 5: ...Sanden Heat Pump Owner s Manual Page 5 of 20 LPG...

Страница 6: ...the unit not being guaranteed Anywhere the lowest temperature reached is under minus 20 degrees centigrade Indoors Applies only to the heat pump unit Anywhere not completely flat unstable or where dr...

Страница 7: ...Sanden Heat Pump Owner s Manual Page 7 of 20...

Страница 8: ...relevant standards Only a licensed person will have insurance protecting their workmanship for six years The unit has been specifically designed for domestic hot water heating and is not suitable for...

Страница 9: ...r no hot water is left in the storage tank Stop using hot water and wait for about 1 hour Consider a change of the electricity supply off peak mode Length of power supply hours may be too short for th...

Страница 10: ...1 HP inlet temperature thermistor wire short circuit E004 HP discharge over temperature 1 E022 HP outlet temperature thermistor wire short circuit E005 HP discharge over temperature 2 E023 HP discharg...

Страница 11: ...places on the heat pump unit Close the plugs after no air is confirmed in the water Connect the power to the heat pump unit and leave a hot water tap open in the home for three minutes Close the house...

Страница 12: ...power supply is cut off i e if it is connected to off peak power However the system will automatically start operation once the electricity becomes available System operation if connected to off peak...

Страница 13: ...ver terminal block cover and screw clamp fitting Connect the power supply line to the terminal block Hold the power supply line below the terminal block with the screw clamp fitting Attach the termina...

Страница 14: ...aminants Water with a pH less than 6 0 may be treated to raise the pH It is recommended that an analysis of the water from a rainwater tank be conducted before connecting this type of water supply to...

Страница 15: ...y 4 5 kW 1 Power consumption Mid Winter Season 0 91 kW 1 1 03kW 2 COP Mid Winter Season 5 0 1 4 4 2 Circuit Breaker Size 20A Design Pressure High Low 14 9 0MPa Protection Raining Class IPX4 Max Operat...

Страница 16: ...Sanden Heat Pump Owner s Manual Page 16 of 20 Hot water storage tank unit REFER Drawing provided with tank GAUS 315EQS Model No GAUS 315EQT GAUS 250EQTB GAUS 160EQTB...

Страница 17: ...ting valve isolation valves check valves electrical switches pumps or fuses 6 The Heat Pump Water Heater System must be sized to supply the hot water demand in accordance with the guidelines in the Sa...

Страница 18: ...Subject to any statutory provisions to the contrary this warranty excludes any and all claims for damage to furniture carpets walls foundations or any other consequential loss either directly or indi...

Страница 19: ...Product Details Heat Pump Serial Number from label on right end ____________________________ Hot Water Tank Serial Number label on tank ________________________________ Date of Purchase Installation...

Страница 20: ...Sanden Heat Pump Owner s Manual Page 20 of 20 SANDEN Heat Pump 40950 44732 Owners Manual AU...

Отзывы: