background image

Sanden Heat Pump – Owner’s Manual 

Page 3 of 20 

Introduction 

The  EcoPlus  Heat  Pump  Water  Heater  System  has  been  designed  using  the 

latest  refrigeration  technology  to 

absorb

  heat  from  the

  outside

  air  to  heat  water.

  The 

refrigerant  (CO

2

)  has  an  extremely  low  global  warning  potential  (GWP) 

so  it  allows  us

to help keep a clean healthy earth for future

 

generations. 

We have also considered the power requirement. By using CO

2

 as the refrigerant we have 

produced one of the most energy efficient units currently available. It’s even more efficient 

when  connected  to  off-peak  power

*

  and  the  noise  level  is  so  low  it  will  operate

 

unobtrusively throughout the night. 

How it works 

The  EcoPlus  Hot  Water  Heat  Pump  System  heats  water  by  transferring  the  heat  from 

the  surrounding  air  to  the  water  using  a  refrigerant.  The  refrigerant  is  heated  by  a  heat 

exchanger that absorbs heat from the surrounding air (Figure 1). 

Figure 1: Heat Pump Water Heater System 

*

Operating  conditions  may  vary  depending  on  the  type  of  off-peak  tariff  that  is  available  in  your

area.  The  unit  must  have  a  minimum  of  5  hours  continuous  power  available  at  all  time

s

  to  allow

the

 

unit to operate without affecting reliability.

63 

Содержание GAU-A45HPC

Страница 1: ...GAUS 300FQS Heat Pump Unit GAU A45HPC This appliance is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless th...

Страница 2: ...e patents or registered designs in the name of Sanden Australia Pty Ltd TRADE MARKS Registered trademark of Sanden Australia Pty Ltd Note Every care has been taken to ensure accuracy in preparation of...

Страница 3: ...currently available It s even more efficient when connected to off peak power and the noise level is so low it will operate unobtrusively throughout the night How it works The EcoPlus Hot Water Heat...

Страница 4: ...Sanden Heat Pump Owner s Manual Page 4 of 20 Do not touch the tap while hot water is being supplied...

Страница 5: ...Sanden Heat Pump Owner s Manual Page 5 of 20 LPG Please contact the EcoPlus authorized installer about insulating the pipes Contact the EcoPlus authorized installer for repair...

Страница 6: ...failure and the performance of the unit not being guaranteed Anywhere the lowest temperature reached isbelow minus 10 degrees centigrade Indoors Applies only to the heat pump unit Anywhere not comple...

Страница 7: ...Sanden Heat Pump Owner s Manual Page 7 of 20 Do not install the unit anywhere it will be exposed to sea water or sea spray...

Страница 8: ...This system delivers hot water exceeding 55o C Reference should be made to AS NZ3500 and or local regulations relating to the need for temperature tempering devices The unit must be stored and transpo...

Страница 9: ...blockage Water flow speed may be dropped due to the heat pump piping bend blockage or crush Check for any piping bend or crush and remove if any Pipes may be frozen If frozen area is found on the pipi...

Страница 10: ...tion error between main PCB to control PCB HC HP water outlet temperature thermistor error E8 High inlet current error J3 HP discharge temperature thermistor error H8 Current error J5 HP suction tempe...

Страница 11: ...efer to figure 4 1 Switching to Air Removing Mode Long press the Up and Down keys to switch to the Heat Setting Mode 2 Press the Up or Down keys to switch to the Air Removing Mode and press the Enter...

Страница 12: ...supply is cut off i e if it is connected to off peak power However the system will automatically start operation once the electricity becomes available System operation if connected to off peak electr...

Страница 13: ...Remove the piping cover screw clamp fitting Connect the power supply line to the terminal block Hold the power supply line below the terminal block with the screw clamp fitting Connect the thermistor...

Страница 14: ...ve due to the dissolution of atmospheric contaminants Water with a pH less than 6 5 may be treated to raise the pH It is recommended that an analysis of the water from a rainwater tank be conducted be...

Страница 15: ...Sanden Heat Pump Owner s Manual Page 15 of 20 Technical data Heat pump Unit Dimension All dimensions displayed in millimeter SPECIFICATION Tested under AS NZ5125 1 2014 requirements...

Страница 16: ...Sanden Heat Pump Owner s Manual Page 16 of 20 Hot water storage tank unit Refer Drawing provided with tank...

Страница 17: ...ts such as the relief valve s are not included in the Rheem warranty A charge will be made for this work Only genuine replacement parts should be used on this water heater The major service includes R...

Страница 18: ...Heat Pump itself is the sole discretion of Rheem on behalf of Sanden 3 Where Rheem determines at its sole discretion that the Heat Pump needs to be removed for repair Rheem may undertake such removal...

Страница 19: ...ay sulfur environments Where the unit fails to operate or fails as a result of ice formation in the piping to or from the EcoPlus Heat Pump Water Heater System Repair and or replacement of the EcoPlus...

Страница 20: ...SANDEN ECOPLUS Owners Manual NZ 320581 Rev A June 2020 Sanden Heat Pump Owner s Manual Page 20 of 20 Contact Rheem New Zealand Free Phone 0800 657 336 www rheem co nz...

Отзывы: