Sanden
Heat
Pump
–
Service
Technical
Book
Page
27
of
48
Check Points
Error
Code
Error Contents
Error Detection Condition &
Diagnostic
Connector
No. or
Maintenance
Monitor No.
Connector
Colour
Judgment & Repair Methods
E044
When 50degC or less is detected
㩷
㩷
㩷
㩷
<Check Items>
㩷
㩷
㩷
㩷
- Check if discharge thermistor is
fallen out
CN4
White
- Put thermistor back into the pocket
on pipe if it is out.
㩷
- Check if expansion valve
connector is fallen out or not
connected properly
CN10
White
- Put it back on properly if it is not in
right position
㩷
- Check resistance between 2
phases on expansion valve coil
(see table)
㩷
㩷
- Abnormal: Valve coil replacement
required (together with PC board)
- Normal: Heat pump unit
replacement required
㩷
HP Discharge
Temperature Thermistor
Detection Error
- leakage on refrigerant pipes
㩷
㩷
- Heat pump unit replacement
required
E045
When detected temperature is
that detected on ambient
temperature ther3degC
㩷
㩷
㩷
㩷
<Check Items>
CN4
White
㩷
㩷
- Check if discharge thermistor is
fallen out from evaporator
㩷
㩷
- Put thermistor back into the pocket
on evaporator if it is out.
㩷
HP Defrost Thermistor
Detection Error
- Malfunction of defrost thermistor
㩷
㩷
- Replace defrost thermistor
E047
When detected high pressure
switch open
㩷
㩷
㩷
㩷
<Check Items>
㩷
㩷
㩷
㩷
- Check on HP connector filter
㩷
㩷
- Remove dust if any
㩷
- Bends or blockings on HP
connection pipes
CN7
White
-Correct piping and remove bends
and blockings
㩷
- freeze on pipes
㩷
㩷
- Check temperature on pipe cover
that is exposed to ambient
temperature
㩷
- Water valve is closed
㩷
㩷
- Open water valve
㩷
- Stopper valve is closed
㩷
㩷
- Open stopper valve
㩷
- confirm tank is filled
㩷
㩷
- fill tank with water if it is not
㩷
- Water circulation pump
malfunction
㩷
㩷
- If Water circulation pump do not
start operating even after turning it on
on the timer setting panel, it is a
malfunction of the water circulation
pump.
㩷
- Check if air exists in water
㩷
㩷
- If noise of air being released can be
heard when water drain plug or PTR
valve is loosened, remove air.
㩷
- Check if HP inlet thermistor is
fallen out
㩷
㩷
- Put thermistor back to the right
position if it is out
㩷
- Check if HP outlet thermistor is
fallen out
㩷
㩷
- Put thermistor back to the right
position if it is out
㩷
- Check if discharge thermistor is
fallen out
㩷
㩷
- Put thermistor back to the right
position if it is out
- Check if expansion valve
connector is fallen out or not
connected properly
㩷
㩷
- Put it back on properly if it is not in
right position
㩷
㩷
High Pressure Side Error
㩷
- Check resistance between 2
phases on expansion valve coil
(see table)
㩷
㩷
- Abnormal: Valve coil replacement
required (together with PC board)
- Normal: Heat pump unit
replacement required