background image

Sanden Heat Pump - Owner

s Manual 

Page 18 of 20 

1. 

 The Sanden “Eco”

®

 Hot Water Heat Pump System must be installed in accordance 

with the installation instructions supplied with the Sanden “Eco”

®

 Hot Water Heat 

Pump System and in accordance with all relevant statutory and local requirements of 
the state in which the water heater is installed.

2. 

 Where a failed component or Sanden “Eco”

®

 Hot Water Heat Pump System is  

replaced under warranty, the balance of the original warranty period will remain 

 

effective. The replaced part or Sanden “Eco”

®

 Hot Water Heat Pump System does 

not carry a new warranty.

3. 

 Where the Sanden “Eco”

®

 Hot Water Heat Pump System is installed outside the 

boundaries of a metropolitan area as de昀椀ned by Sanden or further than 25 kilometers 

from an accredited service agent, the cost of transport, insurance and travelling costs 

between the nearest accredited service agent’s premises and the installed site shall 

be the owner’s responsibility.

4. 

 Where the Sanden “Eco”

®

 Hot Water Heat Pump System is installed in a position that 

does not allow safe, ready access, the cost of accessing the site safely, including the 

cost of additional materials handling and/or safety equipment, shall be the owner’s 

 

responsibility.

5.   The warranty only applies to the Sanden “Eco”

®

 Hot Water Heat Pump System and 

original or genuine (company) component replacement parts and therefore does not 

cover any plumbing or electrical parts supplied by the installer and not an integral 

part of the Sanden “Eco”

®

 Hot Water Heat Pump System. Such parts would include  

pressure limiting valve, isolation valves, non-return valves, electrical switches, pumps 
or fuses.

6. 

 The Sanden “Eco”

®

 Hot Water Heat Pump System must be sized to supply the hot 

water demand in accordance with the guidelines in the Sanden “Eco”

®

 Hot Water 

Heat Pump System literature.

1.   

Repair and replacement work will be carried out as set out in the Sanden “Eco”

®

 Hot 

Water Heat Pump System warranty. However the following exclusions may void the 
warranty and may incur a service charge and/or cost of parts:

2. 

 Accidental damage to the Sanden “Eco”

®

 Hot Water Heat Pump System or any com-

ponent, including: Acts of God, failure due to misuse, incorrect installation, attempts 

to repair the water heater other than by a Sanden accredited service agent or the 

Sanden service department.

3. 

 Where it is found there is nothing wrong with the Sanden “Eco”

®

 Hot Water Heat 

Pump System; where the complaint is related to excessive discharge from the  
temperature and/or the pressure relief valve due to high water pressure; where 

there is no 昀氀ow of hot water due to faulty plumbing; where water leaks are related to 

 

plumbing and not the Sanden “Eco”

®

 Hot Water Heat Pump System or its compo-

nents; where there is a failure of electricity or water supplies; where the supply of 
electricity or water does not comply with relevant codes or acts.

4. 

 Where the Sanden “Eco”

®

 Hot Water Heat Pump System or its component has failed 

directly or indirectly as a result of excessive water pressure, or power surges beyond 

the speci昀椀ed electrical supply.

5.  Over昀氀ow vent drain has not been installed or blocked or corroded.

6. 

 Where the Sanden “Eco”

®

 Hot Water Heat Pump System has rusted as a result of a 

corrosive atmosphere.

7.   Where the unit fails to operate as a result of ice formation in the pipe work to or from 

the Sanden “Eco”

®

 Hot Water Heat Pump System.

8. 

 Where the Sanden “Eco”

®

 Hot Water Heat Pump System is located in a position that 

does not comply with the Sanden “Eco”

®

 Hot Water Heat Pump System installation 

instructions or relevant statutory requirements, causing the need for major disman

-

tling or removal of cupboards, doors or walls, or use of special equipment to bring the 

Heat Pump Water Heater System to 昀氀oor or ground level or to a serviceable position.

Warranty Conditions

Warranty Policy:

Warranty Exclusions

Содержание Eco GAUS-160FQTS

Страница 1: ...Q Unit GAU A45HPC This appliance is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given su...

Страница 2: ...19 Registration for warranty 19 PATENTS This water heater may be protected by one or more patents or registered designs in the name of Sanden Australia Pty Ltd TRADE MARKS Registered trademark of Sand...

Страница 3: ...ure 1 Figure 1 Heat Pump Water Heater System Note Operating conditions may vary depending on the type of off peak tariff that is available in your area The unit must have a minimum of 5 hours continuo...

Страница 4: ...Sanden Heat Pump Owner s Manual Page 4 of 20 Sanden Heat Pump Owner s Manual Page 4 of 20 Do not touch the tap while hot water is being supplied...

Страница 5: ...Sanden Heat Pump Owner s Manual Page 5 of 20 Sanden Heat Pump Owner s Manual Page 5 of 20 LPG Please contact the Dealer about insulating the pipes Contact the Dealer for repair...

Страница 6: ...ature reached is below minus 10 degrees centigrade Indoors Applies only to the heat pump unit Anywhere not completely flat unstable or where drainage is difficult Ensure not to put anything around the...

Страница 7: ...Owner s Manual Page 7 of 20 Sanden Heat Pump Owner s Manual Page 7 of 20 Wipe the unit with a soft dry cloth and do not use chemical items when cleaning Do not use gasoline benzene thinners or any pol...

Страница 8: ...de HB 263 2004 Heated water systems plumbing industry commission AS NZS 3000 Electrical installations known as the Australian New Zealand wiring rules Electrical requirements of the system are 230 240...

Страница 9: ...is found on the piping melt the ice on the pipe and provide a heat insulation Stop valve is closed Open the valve Air absorption is not sufficient due to a blockage on the evaporator Remove the object...

Страница 10: ...mmunication error between main PCB to control PCB HC HP water outlet outgoing temperature thermistor error E8 High inlet current error J3 HP discharge temperature thermistor error H8 Current error J5...

Страница 11: ...hot water taps in the home to remove air Close the hot water taps in the home after no air is con rmed in the water 1 Air Purge Mode Refer to Figure 4 Access Maintenance Mode by depressing the up and...

Страница 12: ...he electrical power supply is cut off i e if it is connected to off peak power However the system will automatically start operation once the electricity becomes available System operation if connecte...

Страница 13: ...re 6 Connect power cables 25mm or less Sanden Heat Pump Owner s Manual Page 13 of 20 Hold the thermistor cable with the code clip and conduit clip Attach the piping cover back on the heat pump unit Fi...

Страница 14: ...likely to be corrosive due to the dissolution of atmospheric contaminants Water with a pH less than 6 5 may be treated to raise the pH It is recommended that an analysis of the water from a rainwater...

Страница 15: ...Sanden Heat Pump Owner s Manual Page 15 of 20 850 690 48 15 2 5 27 5 150 150 70 75 36 412 5 30 26 356 327 3 122 5 122 5 580 23 70 659 23 675 825 300 16 Water Resistance Rating...

Страница 16: ...Sanden Heat Pump Owner s Manual Page 16 of 20 GAUS 160FQTS GAUS 250FQTS GAUS 300FQTS GAUS 315FQTS GAUS 315FQTV...

Страница 17: ...Sanden Heat Pump Owner s Manual Page 17 of 20 Sanden Heat Pump Owner s Manual Page 17 of 20 315L 300L 250L 160L...

Страница 18: ...terature 1 Repair and replacement work will be carried out as set out in the Sanden Eco Hot Water Heat Pump System warranty However the following exclusions may void the warranty and may incur a servi...

Страница 19: ...warrants all parts and labour on the stainless steel tank for 10 years at 100 replacement and for a further 5 years under a pro rata scale culminating in warranty end after 15 years from date of insta...

Страница 20: ...SANDEN Heat Pump 40950 44733 Owners Manual AU...

Отзывы: