background image

2    S&C Instruction Sheet 768-550 

Introduction

    WARNING

The equipment covered by this publication must be installed, operated, and 

 

maintained by qualified persons who are knowledgeable in the installation, operation, and  
maintenance of overhead electric power distribution equipment along with the 

 

associated hazards . A qualified person is one who is trained and competent in:
•  The skills and techniques necessary to distinguish exposed live parts from nonlive 

parts of electrical equipment

•  The skills and techniques necessary to determine the proper approach distances 

corresponding to the voltages to which the qualified person will be exposed

•  The proper use of the special precautionary techniques, personal protective  

equipment, insulating and shielding materials, and insulated tools for working on or 
near exposed energized parts of electrical equipment

These instructions are intended only for such qualified persons . They are not intended 
to be a substitute for adequate training and experience in safety procedures for this 
type of equipment .

NOTICE

Read this instruction sheet thoroughly and carefully before installing or 

 

operating the communication and control unit . Familiarize yourself with the Safety 
Information and Safety Precautions on pages 3 through 5 . The latest version of this  
publication is available online in PDF format at 

sandc.com/en/support/

product-literature/ .

This instruction sheet is a permanent part of your Scada-Mate Switching System 
communication and control unit. Designate a location where you can easily retrieve and 
refer to this publication.

    WARNING

The equipment in this publication must be selected for a specific application . 

 

The application must be within the ratings furnished for the selected equipment .

The warranty and/or obligations described in S&C’s Price Sheet 150 “Standard Conditions 
of Sale Immediate Purchasers in the United States” (or Price Sheet 153, Standard Conditions 
of Sale -Immediate Purchasers Outside the United States) plus any special warranty 
provisions, as set forth in the applicable product-line specification bulletin, are exclusive. 
The remedies provided in the former for breach of these warranties shall constitute the 
immediate purchaser’s or end user’s exclusive remedy and a fulfillment of the seller’s entire 
liability. In no event shall the seller’s liability to the immediate purchaser or end user exceed 
the price of the specific product that gives rise to the immediate purchaser’s or end user’s 
claim. All other warranties, whether express or implied or arising by operation of law, 
course of dealing, usage of trade or otherwise, are excluded. The only warranties are those 
stated in Price Sheet 150 (or Price Sheet 153), and THERE ARE NO EXPRESS OR IMPLIED 
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 
ANY EXPRESS WARRANTY OR OTHER OBLIGATION PROVIDED IN PRICE SHEET 150 
(OR PRICE SHEET 153) IS GRANTED ONLY TO THE IMMEDIATE PURCHASER AND END 
USER, AS DEFINED THEREIN. OTHER THAN AN END USER, NO REMOTE PURCHASER 
MAY RELY ON ANY AFFIRMATION OF FACT OR PROMISE THAT RELATES TO THE 
GOODS DESCRIBED HEREIN, ANY DESCRIPTION THAT RELATES TO THE GOODS, 
OR ANY REMEDIAL PROMISE INCLUDED IN PRICE SHEET 150 (or PRICE SHEET 153.) 

Qualified Persons

Read this  

Instruction Sheet

Retain this  

Instruction Sheet

Proper Application

Warranty

Содержание Scada-Mate CCU-SP

Страница 1: ...nstalling and Connecting a User Supplied Communication Device 13 Connecting an Antenna 14 Connecting a Land Line Interface 14 Connecting Control Power 15 Connecting Remote Terminal Unit Hardware Statu...

Страница 2: ...this publication WARNING The equipment in this publication must be selected for a specific application The application must be within the ratings furnished for the selected equipment The warranty and...

Страница 3: ...ons including recommended precautions are not followed NOTICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed If y...

Страница 4: ...lace in operation or charge batteries in this equipment G 6226 C WARNING Electrical Shock Before energization and at all times when energized G 6289 D WARNING Electrocution Hazard Failure to follow th...

Страница 5: ...stored energy operating mechanism and switch base contain fast moving parts that can severely injure fingers Do not remove or disassemble the operating mechanism or remove access panel on the switch...

Страница 6: ...it is packaged and crated appropriately to avoid damage during shipment A catalog drawing and wiring diagram for the communication and control unit is located in a water resistant envelope in the inst...

Страница 7: ...auxiliary battery charger float charges extra battery packs needed for some Remote Terminal Units and communication devices Battery charger provides continuous float charge to battery packs Switch co...

Страница 8: ...ks provide power for the installation 316L stainless steel NEMA 4X enclosure with three point door latch and padlockable handle Components CCU XP Communication and Control Unit Externally Powered by A...

Страница 9: ...bolt of the switch and the top through bolt of the com munication and control unit when using the standard 35 foot 1067 cm control cable is 28 feet 4 inches 864 cm for switches in the upright vertical...

Страница 10: ...tach an appropriate lifting sling and slowly raise the sling so it becomes taut Carefully raise the control unit to the mounting height and guide it so the through bolts projecting from the utility po...

Страница 11: ...hthecon trolcableplug Secure the plug with the con nector clips Refer to Instruction Sheet 768 500 Retain the dust cover and sensor shorting blocks for future use See Figure 7 STEP 6 Locate the connec...

Страница 12: ...ol unit Maintain a 9 inch 229 mm minimum radius when bending the control cable at the drip loop and at the switch connection Adjust the control cable along the length of the utility pole and form a co...

Страница 13: ...the communication device See Figure 11 Figure 11 Connect power to the communication device using the indicated termi nal block NOTICE The battery charger float charge is factory calibrat ed to accomm...

Страница 14: ...essor When the communication device is supplied by others Prepare a weather tight entrance in the bottom or on the rear of the enclosure in accor dance with utility practice Install the appropri ate s...

Страница 15: ...instances the external ac input on the S C Battery Charger is for use only when configuring the remote terminal unit in accordance with the remote terminal unit instructions Refer to the included wiri...

Страница 16: ...nished testing functionality of the communication and control unit and the auto mated switch if connected to the communica tion and control unit via the control cable can be accomplished with a person...

Страница 17: ...position Then place the battery charger power switch in the On position and confirm that the POWER LED display is lit and the CHARGER OVERVOLTAGE and BATTERY LOW LED displays are not lit When the cont...

Страница 18: ...inside the com munication and control unit in the Local mode See Figures 15 and 16 Then press the OPEN or CLOSE pushbutton as required The interrupter OPEN CLOSED indicator on the end of the switch ba...

Страница 19: ...ess the interrupter contacts are in the Open posi tion Refer to Instruction Sheet 768 500 S C Scada Mate Switching Systems Outdoor Distribution 14 4 kV through 34 5 kV STEP 4 Provision for tagging the...

Страница 20: ...his switch or working on the conductors on either side of the switch test for voltage using proper high voltage test equipment Then install suitable grounding equip ment Failure to observe these preca...

Страница 21: ...changes Record the following Battery identification number Date of installation Battery charging voltage Ambient temperature Date removed from service Battery appearance Physical appearance Examine t...

Страница 22: ...ry charger switch control typically used in the Type CCU XP does not require recalibration therefore a procedure is not refer enced New Battery Preparation The replacement batteries must be in good co...

Страница 23: ...rge the batteries STEP 1 Make sure that the power switch on the bat tery charger is in the Off position STEP 2 Ground the enclosure using the ground lug on the back of the enclosure STEP 3 Place the b...

Страница 24: ...For Type CCU SP Place the battery charger in the External Source position Then put the power switch in the Off posi tion b For Type CCU XP Disconnect the fuse block Then after 15 30 seconds discon nec...

Страница 25: ...in Plastic Outer Case Manufacturer Hawker Energy Products Type Rechargeable sealed lead starved electrolyte Part Number 0809 0016 S C 9931 267 Nominal Voltage each battery pack 12 Vdc at 25oC 77oF Rat...

Страница 26: ...Source 5 hours Dc Output Fuse 10 A 32 V Ac Input Fuse GDC 2A Cyclon Battery Packs in Metal Outer Case Manufacturer Hawker Energy Products Type Rechargeable sealed lead starved electrolyte Part Number...

Страница 27: ...ations and the adjusted magnitude ratio used to calibrate the corresponding voltage sensing input to the RTU To determine the adjusted voltage sensor magnitude ratio s measure and record the voltage s...

Страница 28: ...ge sensor output selector switch is in the 69 Vac position after calibrating the RTU For future reference keep the yellow card in the water resistant envelope and place it in the instruction manual ho...

Страница 29: ...values The corrected sensor ratios may be used by the RTU to adjust the sensor outputs to account for the tolerance variations in the components The magnitude ratio and phase angle shift measurements...

Отзывы: