background image

18

    S&C Instruction Sheet 761-515

Installation

Installing the Rotating Operating 

Handle

When a key interlock is used (standard minor 
modification suffix “-S6”), skip to Step 18 on 
page 29.

When a Type AS-1A Switch Operator is used 

(standard minor modification suffix “-S8” or 
“-S9”), refer instead to S&C Instruction Sheet 
769-500 for installation instructions. When an 
S&C 6801M Automatic Switch Operator is used 
(standard minor modification suffix “-S16”), 
refer instead to S&C Instruction Sheet 1045M-
510 for installation instructions.

Step 15

Back the piercing set screws out of the handle 
yoke and slide the handle assembly up the 
pipe until it is in the location indicated on the 
erection drawing. There should be 6 to 8 inches 
of operating pipe below the operating-handle 
assembly. See Figure 14.

Tighten the piercing set screws on the 

operating-handle assembly enough to hold the 
handle in place, but DO NOT pierce the vertical 
operating pipe.

Step 16

Slide the foot-bearing assembly onto the lowest 
section of pipe at the position shown on the 
erection drawing. See Figure 15. Adjust the 
operating handle assembly until it is two to three 
inches above the foot-bearing assembly. Tighten 
the piercing set screws, piercing the pipe, and 
continue turning until a firm resistance is felt. 
At the same time, use one of the mounting bolts 
to attach one end of the grounding strap (the 
end with the grounding connector attached) 
to the foot-bearing assembly. The grounding 
recommendations in this document may 
differ from the standard operating and safety 
procedures of certain electric utility companies. 
Where a discrepancy exists, the operating 
procedures of the electric utility apply.

If necessary to compensate for the taper 

of the wood pole and to keep the vertical 
operating-pipe aligned and plumb, shift the 
guide bearings toward or away from the pole. 
Alignment slots are provided for this purpose.

Operating handle 
assembly

Vertical operating  
pipe

Piercing set screws 

(2)

Figure 14. Install the operating handle assembly.

Grounding strap

Foot-bearing 
assembly

Figure 15. Install the foot-bearing assembly so the handle is two or 
three inches above the handle yoke.

2-3 inches

Operating handle 
assembly

Figure 16. Attach the grounding strap.

Grounding strap

U-bolt connector

Содержание Alduti-Rupter

Страница 1: ...eplacement Instructions and Labels 4 Location of Safety Labels 5 Safety Precautions 6 Shipping and Handling Inspection 7 Packing 7 Handling 8 Installation Before Starting 9 Mounting to Wood 9 Operatin...

Страница 2: ...able online in PDF format at sandc com Support Product Literature asp Retain this Instruction Sheet This instruction sheet is a permanent part of your S C Alduti Rupter Switch Designate a location whe...

Страница 3: ...nties whether express or implied or arising by operation of law course of dealing usage of trade or otherwise are excluded The only warranties are those stated in Price Sheet 150 and THERE ARE NO EXPR...

Страница 4: ...cautions are not followed NOTICE NOTICE identifies important procedures or requirements that can result in product or property damage if instructions are not followed Following Safety Instructions If...

Страница 5: ...lled and adjusted D E A B C WARNING INSTALLATION OF PIERCING SET SCREWS See illustrations on reverse side of tag 1 Be sure that cutting tip of piercing set screw does not protrude through the coupling...

Страница 6: ...and flash clothing in accordance with safe operating procedures and rules 4 SAFETY LABELS AND TAGS Do not remove or obscure any of the DANGER WARNING CAUTION or NOTICE labels and tags Remove tags ONLY...

Страница 7: ...g pipe if specified 3 Miscellaneous mounting hardware less through bolts for securing the Alduti Rupter Switch to the mounting structure 4 Theappropriatesetofoperatingmechanismcomponentsforthevertical...

Страница 8: ...ed in conjunction with this instruction sheet where applicable Not all mounting arrangements are suitable for power operation Consult your nearest S C Sales Office for details 8 Fused Interrupter Swit...

Страница 9: ...ser s engineering department Mounting to Wood NOTICE When mounting to a wood structure a Belleville washer must be used between the square washer and the nut to maintain fastener tightness in the even...

Страница 10: ...on of interphase pipe These adjustable couplings are attached to the center switch pole except for triangular upright and tiered upright switch mounting configurations See Figure 4 Attach pipe couplin...

Страница 11: ...gure 5 Operating lever Main contact Shunt contact Opening lever Interrupter Open stop Toggle mechanism Toggle stop Adjustable pipe coupling Figure 4 Switch Pole detail 600 ampere switch shown Attach t...

Страница 12: ...Switch to the Mounting Structure Use the following steps to install the switch to the mounting structure Step 5 WARNING DO NOT lift the switch pole units by rigging on the live parts or subject these...

Страница 13: ...nstall the piercing set screws a Back the piercing set screw out of the coupling so the tip does not protrude into the body of the coupling b Insert the operating pipe section into the coupling and fi...

Страница 14: ...ipe coupling to final tightness piercing the pipe and continue turning until a firm resistance is felt When two outboard bearings are used in a double offset arrangement install the connecting pipe be...

Страница 15: ...e of the outboard bearing assem bly See Figures 6 7 and 8 on page 12 Back the piercing set screw out of the body of the pipe coupling clamp before tightening the bolts Torque the clamp bolts to their...

Страница 16: ...bearing and support the operating pipe Insert the pipe section into the universal coupling previously attached to the lower end of the uppermost operating pipe section Do not tighten the clamp bolts a...

Страница 17: ...resistance is felt Step 14 At the universal coupling immediately above the thrust bearing torque the clamp bolts to final tightness and then tighten the piercing set screw piercing the pipe Continue t...

Страница 18: ...on the erection drawing See Figure 15 Adjust the operating handle assembly until it is two to three inches above the foot bearing assembly Tighten the piercing set screws piercing the pipe and continu...

Страница 19: ...procedures of the electric utility apply Installing Operating Handle with Key Interlock Step 18 The interlock group includes a Superior Type B6003 1 Mk II single or multiple key interlock or equivale...

Страница 20: ...p 20 Fasten the operating handle assembly to the lowest vertical operating pipe section using the piercing set screws furnished Figure 19 Tighten the piercing set screws on the oper ating handle assem...

Страница 21: ...kwasher and nut Locking disc inch Figure 20 Attach the locking disc Step 22 NOTICE Key interlocks are intended for proper sequencing of switch operations they are not intended to provide security The...

Страница 22: ...le when lowered fits into the open position slot Mark the location of the open position stop plate on the support plate Step 25 NOTICE DO NOT skip this important step Loose or improperly installed ver...

Страница 23: ...clockwise from the mark See Figure 24 right Make sure the open stop plate lines up with the mark made in Step 24 Tighten the stop plate hard ware to 40 ft lbs d Push the handle into the closed stop p...

Страница 24: ...m after adjusting e When an S C Switch Operator Type AS 1A or an S C 6801M Automatic Switch Operator is used verify that with the switch fully closed there is a clearance of approximately inch between...

Страница 25: ...S C Instruction Sheet 761 515 25 Installation Figure 26 Operation checkpoints...

Страница 26: ...ersurfacesofeachconnector and immediately apply a liberal coating of Penetrox A available from Burndy Corporation or another suitable alumi num connector compound to the brushed surfaces b Wire brush...

Страница 27: ...king fault currents Step 30 To operate the Alduti Rupter Switch a Remove the padlock s from the hasps on the operating handle assembly See Figure 28 on page 26 b If the operating handle assembly is fu...

Страница 28: ......

Отзывы: