V. Operating States &Parameters Adjustment
The new T-506A intelligent temperature controller does not need to adjust the controlling
parameters under normal circumstance. It will self-adjust controlling parameters
according to room temperature for meeting equipment cooling requirements.
The new T-506B intelligent temperature controller is selected constant temperature
control mode as factory setting with water temperature at 25
℃
. User can adjust it as
needed.
T-506A and T-506B controllers are of same functions and structure except factory setting.
1.Temperature control panel introduction
(1) Indicators of temperature controller working status:
COMP
ON, compressor working
SV
ON, solenoid valve working
Heating
ON, heating rod working
INT Ctrl
ON, controller working in intelligent control mode
CT Ctrl
ON, controller working in constant temperature control mode
PARAM Set ON, controller working in parameters setting mode
ALM OUT
ON, alarm output status
Room Temp ON, displaying room temperature
ST DLA
ON, starting up delay status
(2) Press
key to show the room temperature(Room Temp light is on), press
key to
show the real-time frequency value of the flow sensor
,
and 6 seconds later default
display restores.
(3)
keys are for modifying parameters values and
keys are for switching
parameter items.
(4) RST key: confirm
(5) SET key: setting function
2.Restore to factory settings
Before machine startup, press and hold
keys until the controller displays rE.6
seconds after the keys are released, the controller works in normal status. All parameters