background image

         

GS-818 GPS/GSM/GPRS Vehicle Tracker User Manual 

 

21                                                                                                        Copyright © 2011 San Jose Technology, Inc. All Rights Reserved. 

 

Table: Phone Number List Setup Format Description 

 

 

Table: Phone Number List Setup Response Description 

 

SMS Text 

Description 

Start sign. 

username 

 

Default user name of the device. 

 

If you have changed the username, please use the updated one. 

0000 

 

Default password.   

 

If you have changed the password, please use the updated one.   

Mode 5 defines the Phone Book List setup mode. 

+886123456789 

1

st

 cellular phone number, PH-01 

+492234567890 

2

nd

 cellular phone number, PH-02 

+866323456789 

3

rd

 cellular phone number, PH-03 

Bookmode Code: User can define which number will be receiving the SMS report when 

Report route is set at 4. SMS MODE. 

BookMode = 0

No Report

 

BookMode = 1

Report to PhoneBook 1. (Default code for PH-01 setup only) 

BookMode = 2

Report to PhoneBook 2. 

BookMode = 3

Report to PhoneBook 1 and PhoneBook 2. 

BookMode = 4

Report to PhoneBook 3. (Default code for PH-01 and PH-02 setup) 

BookMode = 5

Report to PhoneBook 1 and PhoneBook 3. 

BookMode = 6

Report to PhoneBook 2 and PhoneBook 3. 

BookMode = 7

Report to all three numbers. (Default code for all numbers setup) 

End sign. 

Situation 

Response 

Setup Succeeds 

[username] + Device phone book is updated. 

Setup Fail/ Non-numeric 

data is input for numbers 

[username] + Phone book setup Fail! 

Incorrect password 

[username] + Password setup Fail! 

Incorrect username or 

command format 

[username] + command error 

Note: The program will overwrite the previous phone number list if the user apply new changes. 

Содержание GS-818

Страница 1: ...ology Inc All Rights Reserved This document contains information that is the property of SANAV This document may not be copied reproduced reduced to any electronic medium or machine readable form or otherwise duplicated and the information herein may not be used disseminated or otherwise disclosed except with the prior written consent of SANAV ...

Страница 2: ...g developed and improved from time to time the change in the protocol specification and firmware functions are subjects to change without prior notice SANAV is obligated to modify all the documentation without the limitation of time frame A change notice shall be released to San Jose Technology Inc customers upon the completion of document modification San Jose Technology Inc products are not inte...

Страница 3: ...ker User Manual 3 Copyright 2011 San Jose Technology Inc All Rights Reserved Document Amendments Revision Date Comments 1 2 3 2011 4 2 2 N A 1 6 0 2011 12 10 1 Jamming Detection added 2 Park removed 3 New edition with whole amendments ...

Страница 4: ...le 13 LED Indication 14 SMS Command Introduction 15 Change User Name 16 Change Password 17 Request IMEI Number 18 Set up APN for GPRS Service 19 Set up Phone Book List 20 Set up Book Mode 22 Set up Security Phone Number 23 Set up Real Time Communication 24 Set up Route for Data Transmission 25 Set up URL 27 Set up TCP or UDP IP 28 Set up Auto Report by Time 29 Set up Auto Report by Distance 30 Set...

Страница 5: ...eport 44 SOS Emergency Panic 45 Set up SOS Alarm Report Interval 46 Set up SOS Phone Book 47 Jamming Detection 48 Jamming I O Setup 49 Vibration Setup 50 Vibration Enable Disable 51 I O Input Detection Activation 52 Set up I O Input Status and Interval 53 I O Output Activation 54 Output Action Time Definition 55 External Device Setting 56 GPRMC Data Log Function 57 Define LAUTO Log Interval 59 Era...

Страница 6: ...hts Reserved GPRMC Data Output Format_ HTTP TCP IP or UDP IP 72 GPRMC Data Output Format_ Barcode Reader Scanner 74 GPRMC Data Output Format_ RFID Reader 75 GPRMC Data Output Format_ Extra INFO 76 Appendix 3 NMEA 0183 GPRMC Data Format 77 Appendix 4 Common Error Response 78 Warranty Regulation 79 ...

Страница 7: ...hin 15 meters GSM Transceivers GSM Module Siemens BG2 W General Antenna External GSM antenna SMA Connector External GPS antenna RSMA Connector External Power Supply 8 35V DC Current Consumption Operation 42 81mA 12V DC Standby 8 8 14mA 12V DC Dimension 105 L x 100 W x 30 H mm I O 1 x ACC Detection 2 x Output Max operating current 300mA VIN 2 x Analog Input 0 40 V DC Function reserved 5 x Digital I...

Страница 8: ...y Inc All Rights Reserved Package Contents Standard GS 818 Unit x 1 External GSM Antenna x 1 stick External GPS Antenna x 1 mouse Power Cable x 1 Utility CD x 1 User Manual software USB driver Optional USB Data Cable I O Connector Cable Micro Phone Button Cable Firmware Program Cable ...

Страница 9: ...ht 2011 San Jose Technology Inc All Rights Reserved Hardware Front View I O Serial Color Pin Assignment 1 Out1 3 In4_H 5 In5_H 7 In1_L 9 In2_L 11 In A1 13 In A2 15 Tx 17 BSL 2 Out2 4 GND 6 ACC 8 GND 10 In3_L 12 GND 14 Call SOS 16 Rx 18 ORST Hardware Rear View ...

Страница 10: ...t the battery cable BAT with fuse to the BAT power in Fuse Box such as 10A Interior light shown on the example figure CAUTION DO NOT CONNECT DEVICE POWER TO CAR BATTERY DIRECTLY TO AVOID DEVICE BURN OUT 2 For ACC detection please connect the ACC cable Pin 6 Input_H Brown to the ACC system in Fuse Box such as 15A Cigar Lighter shown on the example figure ...

Страница 11: ...GS 818 GPS GSM GPRS Vehicle Tracker User Manual 11 Copyright 2011 San Jose Technology Inc All Rights Reserved ...

Страница 12: ...V Trigger when pull high 6 ACC Brown Range DC 3V 40V Trigger when pull high 7 Input 1 Low alarm1 Blue Type NC or NO Default NO Range DC 0V 0 6V 8 Ground Black Ground 9 Input 2 Low alarm2 Purple Type NC or NO Default NO Range DC 0V 0 6V 10 Input 3 Low alarm3 Gray Type NC or NO Default NO Range DC 0V 0 6V 11 Input A1 Gray Black Type I O Input analog 1 Range 0V 40V 12 Ground Black Ground 13 Input A2 ...

Страница 13: ...on 1 Output 1 Red White Range DC 8 35V According Voltage IN maximum 300mA 3 Input 4 High alarm4 Yellow Type NC or NO Default NO Range DC 3V 40V Trigger when pull high 6 ACC Brown Range DC 3V 40V Trigger when pull high 7 Input 1 Low alarm1 Blue Type NC or NO Default NO Range DC 0V 0 6V Note Only connect to a passive sensor to GND 8 Ground Black Ground 18 ORST Red Hardware reset ...

Страница 14: ...ing ON and flash every 3s ON GSM in service power saving ON ON GSM not in service Flash ON No SIM Card or PIN code required OFF ON Data Transmission ON Flash once when sending data Receiving a call OFF ON Connect to PC Utility ON ON Low Power ON ON and flash every 5s Enter PARK mode ON ON I O Triggered ON ON SOS Triggered ON Flash for several times PS1 GS 818 generates loud beep sound when power O...

Страница 15: ...chapter Set up URL to change the URL g Before doing any setup please ensure the device is connected with the GSM network The GSM LED must light on And please note the device is not in SOS Panic mode 2 Please note that all the characters which include and comma should be HALFWIDTH form 3 Please be aware of the upper capital lower cases when entering the SMS command to the device 4 While typing any ...

Страница 16: ...een changed Setup format User Name Password Function Code New User Name Command username 0000 1 sanav Table User Name Change Format Description Table User Name Change Response Description SMS Text Description Start sign username Default user name of the device 0000 Default password If you have changed the password please use the updated one 1 Mode 1 defines the user name setup mode sanav New user ...

Страница 17: ...nction Code New Password New Password Command username 0000 2 1111 1111 Table Password Change Format Description Table Password Change Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one 2 Mode 2 defines the password...

Страница 18: ... for network registration and tracking Setup format User Name Password Function Code Command username 0000 imei Table IMEI Inquiry Format Description Table IMEI Inquiry Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated...

Страница 19: ...w the Setup Format below to setup the APN that is provided by your GSM carrier Setup format User Name Password Function Code GPRS Access Point Name APN User Name APN Password Command username 0000 3 internet user password By the way Some PREPAID PHONE CARD SIM modules do not enable or even support GPRS service Please consult with GSM carrier for further information Table APN Setup Format Descripti...

Страница 20: ...ta Use this SMS command to set up the cellular phone book Max of 3 numbers as the following format Setup format User Name Password Function Code PH 01 PH 02 PH 03 Bookmode Code Command username 0000 5 886123456789 492234567890 866323456789 7 Note1 Add or not add the sign in front of the cellular phone number s are both acceptable while the sign should precede the international call prefixes Note2 ...

Страница 21: ...ber will be receiving the SMS report when Report route is set at 4 SMS MODE BookMode 0 No Report BookMode 1 Report to PhoneBook 1 Default code for PH 01 setup only BookMode 2 Report to PhoneBook 2 BookMode 3 Report to PhoneBook 1 and PhoneBook 2 BookMode 4 Report to PhoneBook 3 Default code for PH 01 and PH 02 setup BookMode 5 Report to PhoneBook 1 and PhoneBook 3 BookMode 6 Report to PhoneBook 2 ...

Страница 22: ...use the updated one 0000 Default password If you have changed the password please use the updated one PMOD Mode PMOD defines book mode setup 7 Book Mode Code User can define which numbers will be receiving the SMS report when Report route is set as SMS MODE BookMode 0 No Report BookMode 1 Report to PhoneBook 1 BookMode 2 Report to PhoneBook 2 BookMode 3 Report to PhoneBook 1 and PhoneBook 2 BookMo...

Страница 23: ...is used to set up security phone number Maximum 3 sets are available Setup Format username 0000 Function Code PH 1 PH 2 PH 3 Command username 0000 SCRT 886123456789 886123456780 886123456781 Table Security Phone Number Setup Format Description Table Security Phone Number Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the user...

Страница 24: ...for communication But only limited administrators of Security Phone Number list are allowed to have real time communication if the Security Phone Number list is set Note3 For voice poling mode THE DEVICE will automatically disconnect the incoming call and then transmit current data to the server or assigned route at once If the route is set to SMS mode it will transmit current data to the phone th...

Страница 25: ... by SMS message format to Cellular phone User can choose the route to transmit the data by HTTP TCP UDP protocol individually or with SMS message as a backup route Please refer to the following table for the route setup Setup format User Name Password Function Code Route Code Command username 0000 14 1 Table Route Setup Format Description SMS Text Description Start sign username Default user name ...

Страница 26: ...P SMS mode username Device is switching to HTTP mode Setup Succeeds username Device is switching to SMS mode username Device is switching to HTTP SMS mode without success username Device is switching to SMS mode without success Setup Fail username Device is switching to HTTP mode without success Incorrect password username Password setup Fail Incorrect username or command format username command e...

Страница 27: ...CP IP Transmission Control Protocol or UDP IP User Datagram Protocol server please refer to Set up TCP or UDP IP Note3 HTTP TCP IP UDP IP and SMS are different protocols routes Please refer to Set up Route for Data Transmission to set up corresponded route code for GPS data transmission Table URL or IP Setup Format Description Table URL or IP Setup Response Description SMS Text Description Start s...

Страница 28: ... HTTP TCP IP UDP IP and SMS are different protocols routes Please refer to Set up Route for Transmitting Data to set up corresponded route code for GPS data transmission Table TCP or UDP IP Setup Format Description Table TCP or UDP IP Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 ...

Страница 29: ...mited Auto Reports When you input 0 the device will stop disable Auto Report Setup format User Name Password Function Code Intervals sec Total number of reports Example1 username 0000 6 300 99 Table Auto Report by Time Setup Format Description Table Auto Report by Time Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the userna...

Страница 30: ...Table Auto Report by Distance Setup Format Description Table Auto Report by Distance Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one 6 Mode 6 defines Auto Report setup mode 300 Time Interval period of Auto ...

Страница 31: ...r non continuity 10 times stationary status The total number of reports times is 99 Setup format User Name Password Function Code Intervals sec Total number of reports Distance Interval m stationary Detection times Example1 username 0000 6 300 99 100 10 Table Auto Report by Stationary Setup Format Description SMS Text Description Start sign username Default user name of the device If you have chan...

Страница 32: ...onary Setup Response Description Situation Response Setup Succeeds username Setup OK Device Auto Report setting is updated Setup Fail username Auto Report setting Setup Fail Incorrect password username Password setup Fail Incorrect username or command format username command error Emergency Mode username Username in emergency setup stop ...

Страница 33: ...It will transmit current GPS data to the server or assigned route at once While the route is set to SMS mode it will transmit current data to your cellular phone that you sent the SMS Polling command to the device Setup format User Name Password Function Code Command username 0000 10 Table SMS Polling Format Description SMS Text Description Start sign username Default user name of the device If yo...

Страница 34: ...uto Report is disabled or the number of Auto Reports is sent Note2 After triggering the Angle Report the Auto Report interval set by time or distance will be reset For example an Auto Report is set to report every 60 seconds now an Angle Report is triggered at the 38th second so we expect to see the next Auto Report happen after 22 seconds but the next Auto Report will be triggered in more 60 seco...

Страница 35: ...sable the function of Angle Report 30 means the device will report if the direction of the vehicle exceeds 30 The recommended angle setting is 30 15 Speed km 15 means the device will not report if the speed of the vehicle is slower than 15 km This is used to avoid the misunderstanding due to GPS positioning error if the vehicle is stopped The recommended speed setting is 15km 5 Delay Time Second 5...

Страница 36: ...ction time in order to trigger the event Setup format User Name Password Function Code Enable Disable ON Time OFF Time Command username 0000 acc 1 10 10 Table ACC Status Setup Format Description Table ACC Status Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you...

Страница 37: ...ble ACC Report Setup Format Description Table ACC Report Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one acc Mode acc defines ACC setup mode on To setup the report interval when ACC is ON on off off To setu...

Страница 38: ...Time Buffer Time Command username 0000 overspeed 1 60 5 25 Table Over Speed Detection Setup Format Description Table Over Speed Detection Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one overspeed Mode overs...

Страница 39: ...e are totally 10 groups of Geo Fence coordinates can be set and saved Setup format User Name Password Function Code Latitude Longitude Radius GF Code Command username 0000 gf1 25 002006 121 595135 500 3 Table Geo Fence Coordinate Setup Format Description Table Geo Fence Coordinate Setup Response Description SMS Text Description Start sign username Default user name of the device If you have change...

Страница 40: ...bove SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one gf 1 10 Mode gf 1 10 defines Geo Fence 1 10 setup mode 2458 9741 Latitude ddmm mmmm N N North S South 12125 6460 Longitude dddmm mmmm E E East W West 500 500 meters in radius 0 Clo...

Страница 41: ...eo Fence Coordinate Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one gf1 Mode gf1 gf10 defines Geo Fence setup mode Totally 10 Geo Fence coordinates can be set 25 002006 Latitude degree from 90 000000 to 90 ...

Страница 42: ...ription SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one gf1 Mode gf1 gf10 defines Geo Fence setup mode Totally 10 Geo Fence coordinates can be set 25 002006 Latitude degree from 90 000000 to 90 000000 121 595135 Longitude degree from...

Страница 43: ...nt status of Geo Fence at once The latitude and longitude coordinates will be displayed if the GF is set or it will show OFF Command username 0000 GF READ Table Read Geo Fence Status Response Description Clear Geo Fence Setting User can use this command to Clear all the Geo Fence coordinates Setting at once User may READ the status after entering the command for confirmation Command username 0000 ...

Страница 44: ...f reports Command username 0000 17 60 3 Table Geo Fence Alarm Report Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one 17 Mode 17 defines to set the Geo Fence report interval 60 Time interval in second ranges...

Страница 45: ...ase refer to Set up Phone Book List 3 Send 1st SOS alarm report to the server if available 4 The device Calls SOS phone number if this number is set in the SOS phone book Please refer to Set up SOS Phone Book User can hang up the call anytime within the 10 minutes or the device will disconnect the call automatically after 10 minutes Send the rest SOS alarm reports to the server by report interval ...

Страница 46: ...for SOS alarm report interval ranges is 60 seconds and 3 times Table SOS Alarm Report Interval Setup Format Description Table SOS Alarm Report Interval Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one 15 Fun...

Страница 47: ...aved to flash memory and send to the server when the call ends Setup format User Name Password sosphone SOS Phone Command username 0000 sosphone 886123456789 Note Add or not add the sign in front of the cellular phone number s are both acceptable while the sign should precede the international call prefixes Table SOS Phone Book Setup Format Description Table SOS Phone Book Setup Response Descripti...

Страница 48: ...tection if the previous detection is misjudged For example entering the SMS command as the following allows user to enable or disable jamming detection function Setup format User Name Password JD Enable Disable Command username 0000 JD 1 Table Jamming Setup Format Description Table Jamming Setup Response Description SMS Text Description Start sign username Default user name of the device If you ha...

Страница 49: ... Pulse Width Command username 0000 JD 1 Table Jamming Output Setup Format Description Table Jamming Output Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one cfgO1 cfgO2 Mode cfgO1 defines the jamming detectio...

Страница 50: ...Time Command username 0000 vs on 20 20 10 Table Vibration Setup Format Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one vs Mode vs defines vibration setup mode on To enable the vibration On off off To disable the vibration...

Страница 51: ...ble Vibration Enable Setup Format Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one vs Mode vs defines vibration setup mode on off on To enable the vibration off To disable the vibration End sign ...

Страница 52: ... pins When detecting the devices in vehicle like door open wipers on music on or lamp on etc status the GPRMC data will be reported with alarmx Tracker Status message The x means the number of I O pin Command format username Password io number 0 or 1 Command username 0000 io1 0 Table I O Digital Input Setup Format Description Table I O Digital Input Setup Response Description SMS Text Description ...

Страница 53: ...terval seconds Total number of reports Delay time Command username 0000 io1 NO 60 3 5 Table I O Input Status Setup Format Description Table I O Input Status Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one i...

Страница 54: ...etup Format Description Table I O Output Detection Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one o1 Mode o1 defines o1 status setup mode o1 to o2 setup are available 0 1 0 Switch off the output detection ...

Страница 55: ...etup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one o1 Mode o1 defines o1 status setup mode o1 to o2 setup are available 2 To define the operation of output sensor 20 Output sensor active time seconds The number...

Страница 56: ...llowing is the SMS command to set up the External Device application For the detail please refer to the related manuals Setup format username Password device 1 5 0 Command username 0000 device 1 Table External Device Setup Format Description Table External Device Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username ple...

Страница 57: ...ed to flash and then send to the server will be marked B on Tracker Status message Ex BAUTO BSOS BVIBRATION BACCoff BGFIN etc Table Data Log Setup Format Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one 21 Function code 0 ...

Страница 58: ...0 username setup OK Device log mode is disabled 1 username setup OK Device is switching to backup mode 2 username setup OK Device is switching to interval log mode 3 username setup OK Device is switching to backup filter mode Incorrect function code username log setup fail Incorrect username or password username username or Password error Incorrect function code username command error ...

Страница 59: ...s the following LAUTO saved old data 1 LAUTO saved old data 2 LAUTO saved old data 3 LAUTO saved old data 4 AUTO latest data Totally 5 Auto Reports save to flash as a group Setup format User Name Password Function Code Number of logged times recorded Command username 0000 20 5 Table Data Log Interval Setup Format Description Table Data Log Interval Response Description SMS Text Description Start s...

Страница 60: ...GS 818 GPS GSM GPRS Vehicle Tracker User Manual 60 Copyright 2011 San Jose Technology Inc All Rights Reserved GPRMC Data Log Mode is set 1 username 0000 21 1 ...

Страница 61: ...S 818 GPS GSM GPRS Vehicle Tracker User Manual 61 Copyright 2011 San Jose Technology Inc All Rights Reserved GPRMC Data Log Mode is set 2 username 0000 21 2 Log data interval is set X username 0000 20 X ...

Страница 62: ...se Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one er Function code to erase the saved logged data End sign Situation Response Setup Succeeds username setup OK Device logged data is erased Incorrect function code username...

Страница 63: ...d username 0000 9 Table Reset Format Description Table Reset Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one 9 Mode 9 defines Reset mode End sign Situation Response Setup Succeeds username Setup OK Device resets ...

Страница 64: ...ou attempt to change it Otherwise you may have to consult your GSM operator for the original settings Table CPOL Mode Setup Format Description Table CPOL Mode Setup Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username please use the updated one 0000 Default password If you have changed the password please use the updated one...

Страница 65: ... Rights Reserved Check the CPOL List Use this command to check the GSM carriers list in the SIM card Command username 0000 CPOL Table CPOL Check Response Description Situation Response Success username Preferred Operator List 1 s 2 s 3 s 4 s 5 s Incorrect function code username CPOL setup fail ...

Страница 66: ...ication SMS Report Failure Indication Name when the report route is set as SMS you can set up the device to report either username or IMEI in the failure respond commands The Extra Info Bit is represented by 4 hexadecimal characters Each character represents 4 bit binary number When the bit is set to 1 the specific Extra Info is enabled for the user selection The least significant bit LSB represen...

Страница 67: ... 0000 info 0x0007 Bit No Description bit0 I O ACC battery and power source in Hex Please refer to Extra Info bit 0 Description bit1 HDOP Value bit2 Number of GPS Satellites bit3 CELL ID strength 1 bit4 CELL ID strength 2 bit5 CELL ID strength 3 bit6 CELL ID strength 4 bit7 CELL ID strength 5 bit8 CELL ID strength 6 bit9 CELL ID strength 7 bit10 TA num bit11 RSSI num bit12 username IMEI bit13 Analo...

Страница 68: ... Jose Technology Inc All Rights Reserved Hex Binary 2n n 0 3 0 0000 0 1 0001 1 2 0010 2 3 0011 1 2 4 0100 1 3 5 0101 4 1 6 0110 4 2 7 0111 4 2 1 8 1000 8 9 1001 8 1 A 1010 8 2 B 1011 8 2 1 C 1100 8 4 D 1101 8 4 1 E 1110 8 4 2 F 1111 8 4 2 1 Table 16 Hex Conversion Table ...

Страница 69: ... status is OFF 0011 means the status of Input1 and Input5 are both ON 0320 means Power Source 1 Battery Status 1 ACC Status ON 0300 means Power Source 1 Battery Status 1 ACC Status OFF bit0 Input1 status 0 means Off 1 means On bit1 Input2 status 0 means Off 1 means On bit2 Input3 status 0 means Off 1 means On bit3 Input4 status 0 means Off 1 means On bit4 Input5 status 0 means Off 1 means On bit5 ...

Страница 70: ...data was saved to flash MOVE BMOVE When vehicle travel exceeds the speed limit in Park mode it will trigger the Move event and start sending report according to the setting BMOVE represents data was saved to flash POLL BPOLL When using the SMS to poll the report the event will be POLL BPOLL represents data was saved to flash GFIN BGFIN When entering the geo fence area it triggers the GFIN event BG...

Страница 71: ...device will send a report with DC event BDC represents data was saved to flash CH BCH When the device is plugged in charger for more than 10 seconds it will send a report with CH at the report ended BCH represents data was saved to flash LP BLP When the device is in low power it will send a report with LP BLP represents data was saved to flash ...

Страница 72: ...end the Auto Report according to the settings without fixed and valid GPS signal the device will upload the data to HTTP TCP or UDP server with the data format as the following string Example imei 357853030016621 rmc GPRMC 105521 855 V 2457 7591 N 12125 5684 E 0 00 0 00 011110 1A AUTO Field Description imei IMEI number of the tracker GSM unique identity number GPRMC It is a full sentence of GPRMC ...

Страница 73: ...ithout fixed and valid GPS signal the device will upload the data via SMS message with the data format as the following string Example Username GPRMC 105521 855 V 2457 7591 N 12125 5684 E 0 00 0 00 011110 1A AUTO Field Description Tracker User Name The user name set for the specified tracker GPRMC It is a full sentence of GPRMC including the current Lat Long UTC and others UTC Time Greenwich Mean ...

Страница 74: ...ei IMEI number of the tracker GSM unique identity number GPRMC It is a full sentence of GPRMC including the current Lat Long UTC and others UTC Time Greenwich Mean Time Format hhmmss sss Fix Status The A or V is the letter which indicates the GPS status is fixed A or NOT fixed V Latitude Latitude parameters Format ddmm mmmm N S Northern Hemisphere Southern Hemisphere of Latitude Longitude Longitud...

Страница 75: ...ription imei IMEI number of the tracker GSM unique identity number GPRMC It is a full sentence of GPRMC including the current Lat Long UTC and others UTC Time Greenwich Mean Time Format hhmmss sss Fix Status The A or V is the letter which indicates the GPS status is fixed A or NOT fixed V Latitude Latitude parameters Format ddmm mmmm N S Northern Hemisphere Southern Hemisphere of Latitude Longitud...

Страница 76: ...wing Example imei 353197040074988 rmc GPRMC 084236 000 A 2457 8107 N 12125 5379 E 0 00 0 00 070711 0F AUTO 0300 0 8 10 466 97 3F2D 3391 71 466 97 3E8C 3391 72 466 97 34E6 3391 73 466 97 F19D 3391 79 466 97 34E7 3391 8 0 466 97 FA78 37DD 79 466 97 4973 3391 82 2 21 0 00 0 00 25 17 Field Descriptions GPRMC Format N A 0300 I O acc status battery status and power source in 16 Hex Please refer to Extra...

Страница 77: ...sss 100010 000 UTC Time Time of position fix V Navigation receiver warning Status letter A Status A Data valid Latitude ddmm mmmm 2457 8090 Latitude User datum latitude degrees minutes decimal minutes format N letter N N S Indicator N north or S south Hemisphere Longitude ddmm mmmm 12125 5444 Longitude User datum latitude degrees minutes decimal minutes format E letter E E W indicator E eastern or...

Страница 78: ...onse from the device including command error username or password error and so on Please refer to following table for reference Table Common Error Response Description Situation Response Command error username command error Password setup error username Password setup Fail Geo Fence is not allowed username Geo Fence is not allowed Panic is not functioned username is not in Panic mode ...

Страница 79: ...d by SAN JOSE Technology to be a result of faulty materials or workmanship Instruments mechanically or physically damaged due to the following conditions are beyond our warranty 1 Neglect misuse or abuse such as a incorrect testing installation or operation 2 Place in extreme environments beyond the limits of the specifications 3 Subject to disassembling soldering alteration unauthorized repair an...