97
Chapter 8 DETAIL PERFORMANCE SETTINGS
8.1.1 MAIN BANG SUPPRESSION
Main Bang Suppression is adjusted to suppress main bang, a reflection signal from 3D circuit including wave
guide tube that generally appears as a circular image focusing on the center of the radar display.
Optimum adjustment allows main bang image to remain lightly on the display.
If the main bang is not so big, use the default setting at factory.
Before adjustment:
1.Set the range to 0.125NM.
2.Set the radar video enhance function.
3.Set the radar video process function.
4.Turn the [GAIN] control to the maximum position.
5.Turn the [RAIN] control to the minimum position.
6.Turn the [SEA] control to achieve the strength with which main bang can be judged.
8.1.2 TARGET ENHANCE LEVEL
Sets the level of target enhancement.
Target enhance level can be set from level1 to level4.If the level is set too high, the range resolution may be
declined. So it is necessary to set a value properly.
8.1.3 GAIN PRESET
Adjust the minimum sensitivity level of the [GAIN] control.
Do not change this adjusted level carelessly
The value is usually set to 0 and should not be changed unless there is problem.
Before performing this adjustment, perform the operation described in “NOISE LEVEL ADJUSTMENT”.
Do not change suppression level/area unless absolutely necessary.
Incorrect adjustment will result in deletion of nearby target images and
thus collisions may occur resulting in accidents.
If sensitivity is set too high, unnecessary signals such as noises in the
receiver and false echoes increase to lower target visibility. At the same
time, if sensitivity is set too low, detection of targets such as ships and
dangerous objects may be hindered. Therefore, sensitivity must always be
set to an optimal level.
or
Содержание NCD-2256
Страница 1: ...MARINE RADAR EQUIPMENT INSTRUCTION MANUAL...
Страница 2: ......
Страница 15: ...xiii EQUIPMENT APPEARANCE NKE 1066 SCANNER UNIT NKE 2044 SCANNER UNIT...
Страница 29: ...Chapter 1 INSTALLATION 3 1 2 3 DIMENSIONAL DRAWING OF DISPLAY MOUNTING...
Страница 30: ...Chapter 1 INSTALLATION 4...
Страница 31: ...Chapter 1 INSTALLATION 5 1 2 4 EXAMPLES OF DISPLAY MOUNTING DESK TOP INSTALLATION Mounting bracket...
Страница 32: ...Chapter 1 INSTALLATION 6 DESKTOP MOUNTING TEMPLATE Note Please note the paper size 182 257...
Страница 34: ...Chapter 1 INSTALLATION 8 FLUSH MOUNTING TEMPLATE Note Please note the paper size 182 257...
Страница 43: ...Chapter 1 INSTALLATION 17 NKE 2044 2FT SCANNER Fig 1 3 6 3 Fig 1 3 6 4...
Страница 47: ...Chapter 1 INSTALLATION 21 Fig 1 4 1 3...
Страница 51: ...Chapter 1 INSTALLATION 25 Fig 1 4 2 3...
Страница 157: ...131 Chapter 10 AFTER SALE SERVICE 10 4 RADAR FAILURE CHECK LIST SMR...
Страница 159: ...133 Chapter 12 SPECIFICATIONS Chapter 12 SPECIFICATIONS...
Страница 160: ...134 Chapter 12 SPECIFICATIONS 12 1 SCANNER DIMENSION 12 1 1 NKE 1066 4 40 RUBBER PLATE...
Страница 161: ...135 Chapter 12 SPECIFICATIONS 12 1 2 NKE 2044...
Страница 162: ...136 Chapter 12 SPECIFICATIONS 12 2 DISPLAY DIMENSION 12 2 1 SMR 715 720...
Страница 163: ...137 Chapter 12 SPECIFICATIONS...
Страница 172: ...APPENDIX A 1 APPENDIX NKE 1066 1 5FT SCANNER INTERCONNECTION DIAGRAM FIG A1...
Страница 173: ...APPENDIX A 2 NKE 2044 2FT SCANNER INTERCONNECTION DIAGRAM FIG A2...
Страница 174: ...APPENDIX A 3 SMR 715 720 DISPLAY UNIT INTER CONNECTION DIAGRAM FIG A3...
Страница 175: ...APPENDIX A 4 SMR 715 720 PRIMARY POWER SUPPLY DIAGRAM FIG A4...
Страница 176: ...APPENDIX A 5 SMR 715 720 INTERCONNECTION DIAGRAM FIG A5...
Страница 177: ...APPENDIX A 6 MEMO...
Страница 187: ...APPENDIX A 16 DECLARATION OF CONFORMITY...
Страница 188: ...APPENDIX A 17...
Страница 189: ...APPENDIX...
Страница 191: ...Chapter 3 ADJUST THE RADAR ECHO A 2...
Страница 192: ...Chapter 3 ADJUST THE RADAR ECHO...