7.15.2 How to READ program PATTERN
▶ Below describes process step to read programmed PATTERN profile in TEMP1500.
① Write PATTERN number to read profile in D2001
② Write SEGMENT number to read profile in D2002
③ Write READ TRIGGER('2') in D2007
④ Stay until reading D2008 response DONE('1')
⑤ Reads profile(TSP of temp.& humi. process time etc.)in D2026~D2041
Above process step ① ~ ⑤ is used to read ‘ONE SEGMENT’profile among all in programmed pattern.
To read many segments, reiterate ① ~ ⑤ process step by changing segment number.
Setting ‘0’in D2002 at process step ② will read profile in D2045~D2067.