1st Edition of TEMI2000_Series IM : Dec. 15. 2008 Page 9 / 58
5.2 Type of Communication Command
Two types of commands are provided on TEMI2500. One is general READ/WRITE command to read and write
information on D-Register, and the other is Reference command to read self-information of TEMI2500.
▣
Reference Command
Command
Description
AMI
Displays model name and Version-Revision of TEMI2500
▣
READ/WRITE Command
Command
Description
RSD
Read data in consecutive D-Register in sequence (Read)
RRD
Read data in arbitrary single D-Register (Read)
WSD
Write data in consecutive D-Register in sequence (Write)
WRD
Write data in arbitrary single D-Register (Write)
STD
Register arbitrary single address to monitor (D-Register Monitoring Set)
CLD
Read data in address registered by STD command
(D-Register Monitoring Call)
☞
Each Command can read or write up to 64 D-Register and all of the SED/CLD data will be reset by power OFF,