PAGE 2 of 84 HU-SOUTHWEST-1480 GAS-FIRED HUMIDAIRE UNIT
© SAMUEL JACKSON, INCORPORATED 2005 ALL RIGHTS RESERVED
HU-SOUTHWEST-1480 GAS-FIRED HUMIDAIRE UNIT
The Samuel Jackson Humidaire Unit generates
warm humid air which carries water vapor to
cotton fibers in a form which is quickly and
uniformly absorbed. Samuel Jackson Humidaire
Units have been in extensive use since 1959.
Humid air can be applied at various places in the
gin plant. Humid air applied to lint just before the
bale press reduces the force required to press out
uniform bales and increases lint turnout.
Humid air applied to the cotton just before the gin
stand restores moisture to dry and brittle fiber
before fiber-seed separation. This reduces short
fiber generated by the gin saws. In very dry
climates, humid air applied to seed cotton during
pre-cleaning reduces static electricity problems
that impede cotton flow.
This model incorporates a PLC with a touch
screen to handle combustion controls, diagnostics,
and self-test routines. Diagnostics include
automatic gas valve leak testing, automatic testing
of electrical interlocks, and monitoring of the
water system (water tank level, pump rotation,
overload relay, and scanner adjustment).
All parts of the spray chamber are quickly
accessible through two large access doors. The
mist eliminator, nozzles, float valve, and water
tank screen are easily serviced.
•
POSITIVELY ELIMINATES STATIC
•
REDUCES STRAIN ON PRESS
•
ELIMINATES TIE BREAKAGE
•
PRESERVES THE STAPLE LENGTH
•
IMPROVES TURNOUT
•
ADVANCED PURGE SYSTEM
•
HYDRO-CYCLONE CLEANING
•
ACCESS TO WATER TANK DURING
OPERATION
•
MOISTURE “SPEEDOMETER”
•
MOISTURE MIRROR II COMPATIBLE
•
BUILT IN WATER WATCH
SPECIFICATIONS
At full throttle and 5000 CFM air delivery:
Maximum burner input capacity ...... 3,000,000 BTU/Hr
Maximum natural gas consumption .......... 3,000 CF/Hr
Maximum propane consumption ............. 35 US Gal/Hr
Water evaporation (peak) ...................... 252 US Gal/Hr
Water usage (peak with purge) .............. 290 US Gal/Hr
Minimum water pressure .................................... 20 PSI
Minimum fuel gas pressure .................................. 5 PSI
Minimum compressed air pressure ..................... 80 PSI
Standard Electrical Power:
480 Volts, 3 Phase, 60 Hz
415 Volts, 3 Phase, 50 Hz
380 Volts, 3 Phase, 50 Hz
Drainage facilities should be provided for water drainage
of 500 to 1000 US Gal/24 Hrs (typical).
Содержание Humidaire Southwest
Страница 1: ...HU SOUTHWEST 1480 Humidaire Southwest Gas Fired Humidaire Unit...
Страница 58: ...PAGE 56 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 59: ...PAGE 57 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 61: ...PAGE 59 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 63: ...PAGE 61 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 64: ...PAGE 62 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 66: ...PAGE 64 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 67: ...PAGE 65 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 68: ...PAGE 66 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 69: ...PAGE 67 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 77: ...PAGE 75 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 79: ...PAGE 77 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 83: ...PAGE 81 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...
Страница 85: ...PAGE 83 of 84 HU SOUTHWEST 1480 GAS FIRED HUMIDAIRE UNIT SAMUEL JACKSON INCORPORATED 2005 ALL RIGHTS RESERVED...