HO-1-1143 OIL-FIRED HEATER
© SAMUEL JACKSON, INCORPORATED, 2009 ALL RIGHTS RESERVED
Starting the Heater
Start the heater by turning the two position maintained switch on the face of the control
cabinet to the “I” position. The fan motor, burner motor for combustion air and fuel
pump and digital temperature controller will power on. After a few seconds of self checks
by the primary burner control, the burner should light provided that the air flow switch is
satisfied, the fuel pump is primed and the target temperature (SP) on the digital
temperature controller is lower than the measured temperature.
See “Priming the Fuel Pump” and “Troubleshooting Guide” sections for additional help.