COMPONENTS
Argus Installation and Resource Guide
4
1.3
POWER CARD
The power card is housed in the top-left slot of the panel and has four indicator lights.
The indicators and adjustments are listed below, some of which are not applicable to
cotton gins. Also included is information on power supply fusing.
•
AC Power Indicator (AC Power) on panel door (28 volt bulb): Normally "ON" unless
AC power fails or the bulb fails.
•
LED-1 green DC Power Indicator (PWR): Normally "ON" unless fuse F-1 blows (as
long as the battery is connected to the system and fuse F-2 is in the circuit)
•
LED-2 green Battery Charged Indicator (CHGD):
Not applicable to cotton gin uses.
•
LED-3 amber Battery Discharging Indicator (DISCH):
Not applicable to cotton gin
uses.
•
LED-4 amber Battery Charging Indicator (CHNG):
Not applicable to cotton gin uses.
•
P-2 Voltage Regulator
(Potentiometer): Adjust for 24 volts DC +/- 0.1 volts (measure
across detector output terminals pins 1 & 3) with maximum load on system.
Not
applicable to cotton gin uses.
•
P-1 Battery Charging Voltage Regulator (Potentiometer):
Not applicable to cotton gin
uses.
•
SH1 Battery “YES/NO” Indicator: Jumper should be placed on pins towards desired
side.
NOTE: For cotton gin applications, make sure the black jumper is placed on the
pins on the NO side.
Figure: Power Card
Содержание Argus
Страница 1: ...Installation and Resource Guide...
Страница 2: ......
Страница 29: ...SUPPLEMENTAL Argus Installation and Resource Guide 27...
Страница 30: ...SUPPLEMENTAL Argus Installation and Resource Guide 28...
Страница 31: ...SUPPLEMENTAL Argus Installation and Resource Guide 29...
Страница 37: ...SUPPLEMENTAL Argus Installation and Resource Guide 35...
Страница 38: ...WARRANTY Argus Installation and Resource Guide 36...
Страница 40: ...Argus Installation and Resource Guide 38 This page left intentionally blank...