![Samsung WW22N6850Q Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/samsung/ww22n6850q/ww22n6850q_service-manual_1198058031.webp)
Troubleshooting _ 29
4. TROuBLESHOOTINg
4-1. INfORMATION CODE
►
When an abnormal condition occurs, melody sounds and displays Info. code indications as shown in the
following Info. codes are shown until the status has cleared.
No.
Information
Type
Information
Code
Causes
Corrective Actions
1
Water Level
1C
- The part of the hose where the water level sensor
is located is damaged (punctured).
- The hose is clogged with foreign material.
- The hose is folded.
- Too much lubricant has been applied to the
insertion part of the air hose.
- Hose engagement error (disengaged)
- Part fault (Faulty internal soldering)
- The water level sensor terminal is disengaged.
- Main PBA fault
• Water level sensor fault
• The water level sensor terminal
is disengaged
•The part of the hose where the
water level sensor folded
• Main PCB fault.
2
Motor
3C
-
The PBA connector terminal is not connected.
-
The motor spin net is not engaged.
-
The motor’s internal coil is damaged (short-
circuited or cut)
- Foreign material (a screw) has entered the motor.
- Constrain because of Foreign material between
PULSATOR and BOWL
• Washing motor fault
• Check Washing motor
connector
• Washing motor rotor/stator fault
• Main PCB fault
3C1
- Motor overloaded due to too much laundry (Non
sensing)
- PBA fault
3C2
- The motor driving error from the PBA is weak :
Unstable relay operation, etc.
3C3
- The IPM terminal of the main PBA is not
connected.
- The DD motor cover is out of place.
3C4
- The PCB housing terminal is not connected.
- PBA fault
- DD motor fault
3CP
- PBA fault
- Pulsator motor fault
• Pulsator motor fault
• Main PCB fault
3
Water Supply
4C
- Foreign material is entering the water supply valve.
- The water supply valve terminal is not connected.
(Wire disconnected)
- The warm water and rinse connectors are wrongly
connected to each other.
- This occurs if the PCB terminal from the drain
hose to the detergent drawer is not connected.
Check whether the transparent hose is folded or
torn.
- This occurs Water pressure is weak, a certain time
delay.
- This occurs Water Valve by freezing in winter
season.
• Water supply valve fault
• Main PCB fault
• Freezing by winter season
4C2
- The water temperature is sensed as higher than
50 ˚C in the Wool or Lingerie courses
-
4
Drain
5C
- The pump motor impeller is damaged internally.
- The wrong voltage (220 V → 110 V) is supplied to
the parts.
- Part fault
- This occurs due to freezing in the winter season.
- The drain hose is clogged. (Injection error, foreign
material)
- Clogged with foreign material.
- The water pump terminal is not connected : rubber
band, bills, cotton, hair pins, coins.
• Drain pump fault
• Freezing by winter season
• Check inside foreign material of
drain pump
• Main PCB fault
WW22N6850NX-A2_SM.indb 29