Страница 1: ...odes then turn Jog Dial to view error codes Push Start Pause while the code is displayed to view the number of cycles since the error occurred Peripheral Main PCB input Tests 1 Select My Cycle Then turn the Jog Dial so that the Extra Rinse LED is turned on Next press the Start Pause Key The Water Temperature will be displayed in Fahrenheit 2 Select My Cycle Then turn the Jog Dial so that the Exten...

Страница 2: ... tsWF419 RevE 03 21 2011 2 WF419AA XAA ...

Страница 3: ... 7 Pin 4 White and CN7 Pin 5 Orange Operating voltage at Room temperature Operating Resistance at Room Temperature Power off Dis connect CN7 4 2VDC 5VDC May indicate a connector issue 50 57kΩ Door Switch Check Test 1 Test 2 Connector CN4 Pin 1 Pink and CN4 Pin 3 Gray 25VDC Door Open 0VDC Door Closed Operating Resistance with power off 24kΩ Water Level Sensor Check Test 1 Test 2 Voltage Connector C...

Страница 4: ...tance is 16 6 Ω Steam Heater Relay Check Test 1 Test 2 Connector CN2 Pin 3 Brown and RY4 heater relay Pin 1 Orange 120VAC with the Heater On and 0VAC with the Heater off Power Off heater resistance is 15 6 Ω Error Type Error Mode Details LED LCD Water Level Sensor LE 8 Check the Hose where the sensor is connected may be loose pinched damaged or clogged Also check the sensor it may be disconnected ...

Страница 5: ...use of moisture If the main PCB s communication circuit is faulty replace it EEPROM Fault 11 Go to EEPROM Clear Mode If display shows FAiL Replace Ma chine Control Board Switch Error Main Relay Error E2 15 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switchin...

Страница 6: ...ly Verify the water valves shut off fully Finally check the water level sensor Temperature Sensor Error 29 The washing heater temperature sensor in the tub has an error Check the connections for the washing heater temperature sensor connector Unbalance Error dC 10 Check the type of laundry Check whether it may cause an unbal anced situation Educate the consumer in this case to press pause repositi...

Страница 7: ...ain during the following rinse cycle removing any remnants Stacking Kit Model No SK 3A1 XAA SK 4A XAA SK 5A XAA Samsung washers and dryers can be stacked to maximize usable space An optional stacking kit is available for purchase from your Samsung retailer Location considerations Do not install your washer in areas where water may freeze since your washer will always maintain some water in its wat...