![Samsung WA3100M PJT Скачать руководство пользователя страница 24](http://html2.mh-extra.com/html/samsung/wa3100m-pjt/wa3100m-pjt_service-manual_5240434024.webp)
22 _ Troubleshooting
Code T
ype
Code Mode
Causes
Corrective Actions
Description of Photo
W
ater Supply
Code
►
Extra
High
LED Flash
This may occur when the
water supply valve is
defective.
•
If the water supply valve is broken
, replace
the valve.
•
Check if the water supply is block
ed due
to an alien substance in the valve or check
if the water is supplied to the machine. If
a problem is found, take the appropriate
countermeasure.
•
Check if the water supply is block
ed due to
the water being frozen.
•
If the P
BA
Relay malfunctions, replace the
PBA.
1.
Measure the resistance of the
water supply valve.
-
Resistance
:
0.9KΩ
to
1.1KΩ
between the terminals of the
W
ater Supply V
alve.
2.
Check whether there is foreign
material in the W
ater supply
valve
filter
.
►
Hot&Low
LED Flash
This may occur when the
main PCB is defective.
This may occur due to
frozen water
.
Drain Code
►
Low
LED
Flash
This may occur when the
drain pump is defective.
•
Check if there is any alien substa
nce inside
the draining pump motor
.
•
Check the natural drain in the sam
e manner
.
•
Check if there are any incorrect connections
or broken wires.
•
If the m
achine m
alfunctions interm
ittently
when the wash tub water temperature is
high, replace the pump.
•
If the m
otor stops due to the water being
frozen in winter
, remove the frozen water
referring to the relevant repair procedures.
Check the drain pump resistance.
(Resistance
:
13.5
~
16.5
Ω)
This may occur due to
frozen water
.
Check if there is any alien
substance inside the
draining pump.
This may occur when the
main PCB is defective.
Communication
Code
►
W
arm
LED
Flash
The signals between the sub
and main PBAs are not
sensed.
•
Check the wire connections and t
erminal
contacts between the sub and main PBAs.
•
Check for disconnected wires.
•
Check whether
the sub PBA
is short-circuited
because of moisture.
•
If the m
ain PBA
’s communication
circuit is
faulty
, replace it.
-
Incorrect wire connections
between the sub and main
PBAs.