8
3.DRAIN ERROR
(1) When the water level does not fall under Reset level after 15 min. has passed since starting to drain.
(2) Generates ERROR MELODY 5 times.
(3) DISPLAY : 'dE' 0.5 sec. ON/OFF
(4) How to Clear : Press Start Key to clear the Error status and to resume Water Drain.
4. DOOR OPEN ERROR
(1) When the Door is opened during the Intermittent Spin and Spin.
(2) Generates ERROR MELODY 5 times.
(3) DISPLAY : 'UE' 0.5 sec. ON/OFF
(4) How to Clear : Close the Door.
5.DEFECTIVE MOTOR ERROR
(1) When a trouble is detected with ML, MR, Weight sensing curcuit after weight sensing
(2) Give error melody 5 times
(3) Display : '3E'
(4) How to clear : press the start key to proceed wash course in the high level.
(1) Initial value of reserved function is 3 hours (base value) and each key-in updates reserved time by 1 hour.
(2) All key-in is valid when real wash course giving key melody sound performs.
(3) Reserve setting is valid for all courses.
(4) All key in is not valid except for water supply and start key after pressing the start key with the elapse of 10 min.
(5) It is in the mode of reserve function when water level is selected by using start key after performing the first
weight sensing. After that the initial water supply function proceeds.
2-4-3 AUTO POWER OFF FUNCTION
(1) Auto Power OFF function automatically turns Power Relay OFF after all the selected process is finished and
End Melody is generated.
2-4-4 RINSE SOLUTION INPUT FUNCTION
(1) The function opens the Rinse Input Valve as below.
(2) The function adds rinse solution at the last stage of Rinse, and it turns OFF the Rinse Solution Valve and
performs Water Supply if the number of Rinse times is increased while adding the rinse solution is in operation.
(3) If the number of rinse times is increased while adding the solution is in operation, stop adding and resume
adding for the remaining time.
(4) If Pause key is pressed while it is adding the rinse solution and then Start key is pressed, it stops adding the
rinse solution and then resume adding for the remaining time later at the last stage of rinsing.