22 _ Troubleshooting
Check Type
for uSA
Causes
Remarks
foaming
Detected
SUD
- This occurs when too much foaming is detected. It is also
displayed while foaming is removed. When the removal is
finished, the normal cycle proceeds.
“Sud” or “SUdS” is displayed when too much foaming is
detected and “End” is displayed when the removal of the
foaming is finished.
(This is one of the normal operations. It is an Check for
preventing non-sensing faults.)
Mems PBA
Check Detected
8C1
- Check detected in the Mems PBA or data Check detected.
Check the wire connections.
Replace if necessary.
1. Check the wire connections.
2. Replace the Mems PBA.
3. Main PBA wire connection Check or PBA’s silver nano part
malfunction. Replace if necessary.
8C2
8C
Clutch motor
PC
- When position of the clutch can’t be detected.
Clutch sensor
PC1
- After position of the clutch is detected, if the signal of the clutch
hall goes wrong, occurs error.
System Check
SF1
- Micro Controller Operation Fail.
Replace Assy PCB.
SF2
SF3