3
2. Disassembly and Reassembly
2-1 Indoor Unit
Stop operation of the air conditioner and remove the power cord before repairing the unit.
No
Parts
Procedure
Remark
!
Front Grille
1) Stop the air conditioner operation and block the
main power.
2) Seperate tape of front panel upper.
3) Contract the second finger to the left, and right
handle and pull to open the inlet grille.
4) Take the left and right filter out.
5) Loosen one of the right fixing screw and seper-
ate the terminal cover.
6) Loosen three fixing screws of front grille.
7) Pull the upper left, right and Center of discharge
softly for the outside cover to be pulled out.
8) Pull softly the lower part of discharge and push
it up.
Caution;
Assemble the front panel and fix the
hooks of left, right and Center
* Take the Deodorizing and Electrostatic filter
out. (Optional)
1-00189A(2) 3/14/01 4:25 PM Page 3
Содержание US18A6RC
Страница 23: ...22 6 PCB Diagrams 6 1 Main PCB PD TQ24AIR 01 1 00189A 2 3 14 01 4 26 PM Page 22 ...
Страница 25: ...24 7 Wiring Diagrams 7 1 Indoor Unit AS24A2RC AS18A6RC 1 00189A 2 3 14 01 4 26 PM Page 24 ...
Страница 27: ...26 MEMO 1 00189A 2 3 14 01 4 26 PM Page 26 ...
Страница 28: ...27 8 Schematic Diagrams 8 1 Indoor Unit ...
Страница 29: ...ELECTRONICS 1 00189A 2 CO 3 14 01 4 24 PM Page 2 ...