Samsung Electronics
5-6
Troubleshooting
5-3-4 (F) Check of indoor unit fan motor
Check whether the wire of fan motor is connected to the connector of control board (CN43,
CN73) of indoor unit.
Check whether the error mode displays after the strong revolution for approximately 15 seconds
since aircon is on.
-> In case the error mode displays after the fan motor is rotating for 15 seconds
→
Defect of
H A L L IC of fan motor and Control board
-> In case that the error mode displays without running of fan motor after 15 seconds.
→
Operate with the pin of SSR(SS71) short of indoor unit control board and then if the fan
motor does not run, it is the fan motor defect.
If it rotates, it is the defect of control board (SS71, IC07, IC04).
5-3-5 (G) Check of communication line between the indoor unit and outdoor unit
(Communication error mode)
1 ) Check of connection
Check whether the cable wire connecting the indoor unit with outdoor unit is correctly connect-
ed to the C, N, R terminal. (If the wire is connected re v e r s e l y, the communication error occurs)
If the cable connecting the indoor unit and outdoor unit is longer than 20 M, error mode occurs
(shorten the cable length).
(Check of indoor unit)
Check whether the connection wire of the terminal block and control of indoor unit board is cor-
re c t .
♦
Sky -blue : connected to TB72
♦
B rown : connected to #3 terminal of RY 7 1 .
♦
Black : Connected to CN75
(Check of outdoor unit)
Check whether the connection wire of the terminal block and control board of outdoor unit is
c o r re c t .
♦
Sky -blue : connected to TB1
♦
B rown : Fuse terminal - connected to TB72
♦
Black : Connected to CN71(Connected to the R701 line)
2 ) Check of power supply to the outdoor unit
After operation of aircon, select the turbo mode and approximately 3minutes later, check whether
the red color lamp of control board (to be seen if the top cover of outdoor unit) is on.
-> If the red lamp (LED 3) is not on, check the power part of control board of outdoor unit.
♦
Check the connection of re a c t o r, polarity of C-ELEC (2200µF/400V) and connection of two diode
- bridge.
-> If the red lamp (LED3) is on and green lamp is flickering, it is normal.
Содержание UQV12A0TE
Страница 36: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit ...
Страница 38: ...Samsung Electronics 6 3 6 2 Outdoor Unit 26 27 24 25 ...
Страница 42: ...6 7 Samsung Electronics 6 3 3 Ass y control Outdoor unit DB93 00022A UQV12A0TE Exploded Views and Parts List ...
Страница 46: ...Samsung Electronics 7 3 7 2 ASS Y PCB OUT DB93 10604A UQV12A0TE UQV09A0TE ...
Страница 49: ...Samsung Electronics 8 1 8 Wiring Diagrams 8 1 Indoor Unit ...
Страница 50: ...Samsung Electronics 8 2 8 2 Outdoor Unit UQV12A0TE ...