Operating Instructions and Installation
3-11
Samsung Electronics
3-2-2(h) Refrigerant Refill
• Refill an air-conditioner with refrigerant when refrigerant has been leaked at installing or using
1. Purge air(for new installation only).
3. Connect the tank to refill with Refrigerant
4. Set the unit to Low pressure checking mode.
* Press the ON/OFF switch for 5 second.
*All the lamp is blink on the indoor unit.
7. Stop operation of the air conditioner.
9. Close the cap of each valve.
2. Turn the 3-way valve clockwise to close,
connect the pressure gauge(low
pressure side) to the service valve, and
open the 3-way valve again.
5. Check the pressure indicated by the
pressure gauge(low pressure side).
* Refer to Low pressure graph.
6. Open the refrigerant tank and fill with refrig-
erant until the rated pressure is reached.
* It is recommended not to pour the
refrigerant in too quickly, but gradually
while operating a pressure valve.
8. Close the 3-way valve, disconnect the
pressure gauge, and open the 3-way
valve again.
Suspension hook
High
pressure
gauge
Hand
wheel
Finger tight
fittings
Connected to
high pressure
side
Charging
line
For mounting
other and of
hose when
not in use
Compound
gauge
Press this ON/OFF
Switch for 5sec.
And then the
Aircondationer
operating on rating
speed.
ON/OFF
Содержание UQV12A0TE
Страница 36: ...Samsung Electronics 6 1 6 Exploded Views and Parts List 6 1 Indoor Unit ...
Страница 38: ...Samsung Electronics 6 3 6 2 Outdoor Unit 26 27 24 25 ...
Страница 42: ...6 7 Samsung Electronics 6 3 3 Ass y control Outdoor unit DB93 00022A UQV12A0TE Exploded Views and Parts List ...
Страница 46: ...Samsung Electronics 7 3 7 2 ASS Y PCB OUT DB93 10604A UQV12A0TE UQV09A0TE ...
Страница 49: ...Samsung Electronics 8 1 8 Wiring Diagrams 8 1 Indoor Unit ...
Страница 50: ...Samsung Electronics 8 2 8 2 Outdoor Unit UQV12A0TE ...