12
3-2-6 If Operation By Remote Control Unit Is Impossible. (Initial Diagnosis)
1) Troubleshooting procedure
Remove power cord and plug in again approx. 5 Seconds
Is operation lamp blinking?
Check as in the procedure “NO Power parts”.
Refer to page 8.
Normal
Replace battery.
LCD is faulty.
Replace button.
Micom is faulty.
Receiver module is faulty.
Q601(C4375Y) or Q602(C1623Y) is faulty.
IR LED(CL-1L5EU) is faulty.
“ “ sound heard from the indoor unit when ON/OFF
button on the remote control unit pushed?
Voltage of battery less than 2.5V (Remote Control Unit)?
LCD display status of REMOCON normal?
Voltage at PIN #30 of Remocon Micom change?
Voltage at collecter of Q601 or Q602 change?
Voltage at pin #26 of micom (IC04) change (INDOOR UNIT)?
Micom (IC04) is faulty.
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
NO
NO
YES
Transmission display lamp ( ) blinking when ON/OFF
button on the remote control unit pushed?
DB81-00188A(4)-1** 10/30/02 10:44 AM Page 12
Содержание UQ18A0RCD
Страница 23: ...22 MEMO DB81 00188A 4 1 10 30 02 10 44 AM Page 22 ...
Страница 25: ...24 6 PCB Diagrams 6 1 Main PCB PD SH30ZC 02 DB81 00188A 4 1 10 30 02 10 45 AM Page 24 ...
Страница 27: ...26 7 Wiring Diagrams 7 1 Indoor Unit AQ24A2RC AQ18AORCD AQ18A6RC DB81 00188A 4 1 10 30 02 10 45 AM Page 26 ...
Страница 30: ...29 MEMO DB81 00188A 4 1 10 30 02 10 45 AM Page 29 ...
Страница 31: ...31 30 8 Schematic Diagrams 8 1 Indoor Unit DB81 00188A 4 1 10 30 02 11 00 AM Page 30 ...
Страница 32: ...32 MEMO DB81 00188A 4 1 10 30 02 10 45 AM Page 32 ...
Страница 33: ...ELECTRONICS 1 00188A 4 CO 10 30 02 10 43 AM Page 2 ...