Samsung UPC4082E Скачать руководство пользователя страница 12

E-

12

Drain Hose

Drilling a Hole in the Wall

◆ 

Drill a hole of 60mm in diameter to the outside.

◆ 

The drilling should be done at a distance of less than
200mm from the floor facing the indoor unit.

◆ 

Extend the drain hose to the drain hose connected to 
the drain pan, and fix it with the tape or a cable-tie to 
prevent separation. Then make a covering of it so 
that water cannot flow outwardly.

CAUTION

1. As the draining is of natural drain type, make the drain hose direct 

downward.

2. If there is any foreign substance in the drain plate, it may clog the 

drain pipe. Therefore, be sure to remove the foreign substance
inside after installation.

3. After completion of installation, be sure to pour water into the drain 

pan, and then check the draining condition.

(There is no problem in draining when the draining is completed 

within 20 seconds.)

Ø 60mm

Less than
200mm

Foamed Polyethylene

Insulator

Vinyl Chloride(Inner diameter ø18mm,

Outer diameter ø23mm)

Piping Material

INSTALLATION METHOD

Drain hose

Drain pan

Indoor and outdoor

connection

Insulation

Band

Содержание UPC4082E

Страница 1: ...Colmado de Aire Acondicionado Refrigeración Climatiseur Monobloc de Type Split Refroidissement E S F A DB98 04436A 1 INSTALLATION MANUAL MANUAL DE INSTALACIÓN MANUEL D INSTALLATION Indoor Unit APC4082E APC4082EC Outdoor Unit UPC4082E UPC4082EC ESPAÑOL FRANÇAIS ...

Страница 2: ...the installation of your unit the user should not attempt to install his her unit by himself herself Do not attach any electric heating device or electric heater to the unit Do not attempt to disassemble or modify the unit by yourself It may cause machine trouble electric shock or fire Ø 60mm Less than 200mm TABLE OF CONTENTS Absolute Checkpoints Refer to page 12 for detailed procedures 1 Drain ch...

Страница 3: ...RTS LIST Connection Parts Others 1 2 3 4 5 6 7 Drain hose Connection pipe Connection pipe Insulation for piping Finishing tape Leg holder for outdoor unit Foot holder Cable clamp 1 1 1 2 4 4 1 No Q ty Remarks Piping Box Part Name 3 8 ø9 52mm 3 4 ø19 05mm 8 9 10 11 12 13 1 1 4 4 1 1 1 No Q ty Remarks Piping Box Indoor Unit Part Name ...

Страница 4: ... the unit on the borderline with your neighborhood A place where strong wind does not head against the air outlet of the outdoor unit If a strong wind heads directly against the air outlet at the time of cool operation a safety device can be operated Do not install the outdoor unit at an unstable place such as outer wall of an apartment or building The outdoor unit may fall down causing severe per...

Страница 5: ...purchased by the user Avoid octopus type wiring as it can cause a drop in voltage thus resulting in poor performance of the automatic control circuit Be sure to install circuit breaker separately purchased by the user Be sure to connect the grounding wire Electric power spec Model Power Sub switch Electric wire Allowable voltage SPEC APC4082E APC4082EC Single phase 220 240V 50Hz 50A 4 0mm2 separat...

Страница 6: ...l by unfastening two screws 2 Disassemble anchorage by removing and screws 3 Connect assembly cable to same number in terminal block 4 Secure earth wire by tightening screw 5 Align the A with B part then secure anchorage by tightening and screws 6 Reinstall the cover control and screws Wires must pass through C and D Indoor and Outdoor Connection Wiring Indoor unit Outdoor unit Circuit breaker Cov...

Страница 7: ...E 7 ENGLISH Wiring diagram Indoor unit terminal block Indoor unit Outdoor unit Control box Indoor and outdoor connection wire Power cable Earth Earth Earth Power Cable ...

Страница 8: ...chor bolt 1 Fix the unit on a flat rigid floor using the anchor bolt Anchor bolt M10 x 4 points separately purchased When using the leg holder of the outdoor unit 1 Insert the foot holder 4EA 2 Remove the nut fastened to the leg holder and then insert the leg holder into the hole of the outdoor unit leg 3 Fix the unit securely with the nut ...

Страница 9: ...g care not to cause any leakage of refrigerant 4 Be sure to insulate the pipe with appropriate insulation material 5 Insert the drain hose into the drain pipe and connect them by tying them to the cable tie to prevent any water leakage 6 After completion of the installation check the connecting area for any gas leakage 7 Wind a finish tape when the wiring of the refrigerant pipe the unit and the d...

Страница 10: ...nnection of Refrigerant Piping Outer Diameter ø 9 52mm ø 19 05mm A mm 1 8 2 2 Flare Processing 1 Cut the pipe using the pipe cutter 2 Insert the flare nut into the pipe and then perform the flare processing Oblique Roughness Burr ...

Страница 11: ...unbending the pipe more than twice makes the bending work increasingly difficult 3 You may use the spring inserted into the gas pipe instead of the bender to bend the pipe 4 When you bend the pipe using the spring hold the pipe with both hands to prevent any distortion and secure a minimum bending radius of more than 100mm Tightening of Connection Parts Align the center of the connection piping an...

Страница 12: ...tural drain type make the drain hose direct downward 2 If there is any foreign substance in the drain plate it may clog the drain pipe Therefore be sure to remove the foreign substance inside after installation 3 After completion of installation be sure to pour water into the drain pan and then check the draining condition There is no problem in draining when the draining is completed within 20 se...

Страница 13: ...slightly with a hammer a hole is made After connecting the piping and drain hose insert the rubber cap as shown in the figure CAUTION When installing the air conditioner as a fixture make a U trap 1m with refrigerant piping and power cable Holes for piping connection 3 points U trap 1m Extra cable About 1m The shape of hole may varies with the models ...

Страница 14: ...g vacuum pump for about 10 minutes Close the valve of the low pressure side of manifold gauge clockwise Make sure that pressure gauge show 0 1MPa 76cmHg after about 10minutes This procedure is very important in order to avoid gas leak Turn off the vacuum pump Remove the hose of the low pressure side of manifold gauge 5 Set valve cork of both liquid side and gas side of packed valve to the open pos...

Страница 15: ... the refrigent slowly checking the pressure Check the pressure of the pressure gauge Check whether the low pressure side is within the range of 4 5 5 6kg cm2 G outside temperature 35 C Stop operation Close the gas pipe side valve and loosen the pressure gauge connected Then open the gas pipe side valve again Tighten the cap of each valve using a specified tool OUTDOOR UNIT Gas pipe side Liquid pip...

Страница 16: ...gain after completion of installation 1 Check the piping connection area for any gas leakage 2 Is the drain hose properly connected 3 Is the insulation of the piping in good condition 4 Is grounding properly made Insulation Indoor connection area Outdoor connection area ...

Страница 17: ...test operation 2 Never attempt to start test operation by force pressing the electronic contactor as it is very dangerous This is very dangerous as the protective device does not work 3 Be sure to perform the test operation after installation It is easy to start the test operation in winter if you increase the sensor temperature to 23 C 25 C by holding the indoor temperature sensor Cooling operati...

Страница 18: ...ATOR Select installation place Connect telephone cable Connect power cable Check the password Check and test operation Selection of Installation Place Decide the installation place referring to the figure below about 10m Indoor unit about 10m ...

Страница 19: ... the digital telecommunicator There must be no obstacles between the indoor unit and the digital telecommunicator Select the place above 30cm or more from the floor It is recommended that the digital telecommunicator faces the front of the indoor unit 30cm ...

Страница 20: ... cable and the LINE PHONE cable Otherwise the digital telecommunicator will not be operated The digital telecommunicator does not work if it is connected with the key phones normally used in the office Connect DC adaptor to the digital telecommunicator Connect telephone line Line phone Line Line Digital telecommunicator DC adaptor Plug in ...

Страница 21: ...ress the On Off button on the indoor unit once within 3 seconds It will set the password to 00 Then if the digital telecommunicator beeps by pressing the RESET button again If you cannot hear a beep after following above steps check the distance between the digital telecommunicator and the indoor unit Checking and Testing Operation Call a place where the digital telecommunicator is installed then ...

Страница 22: ...ELECTRONICS THIS AIR CONDITIONER IS MANUFACTURED BY ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR CE CLIMATISEUR EST FABRIQUE PAR Printed in Korea ...

Отзывы: