40
TCON Board:
Two LVDS Cables from Main Board
1.
Test for 13VDC at both
sides of two Fuses on
the TCON Board.
2.
If no 13VDC on either
side of fuses, check
13V feed from the
LVDS Cables & Main
Board.
3.
If 13VDC only on one
side of fuses replace
defective TCON Board
4.
Inspect LVDS and
Panel Cable
Connectors..
T-CON TEST
T-CON BOARD
T-CON BOARD
TCON Board:
Two 13V DC Fuses