Samsung Electronics
12-3-4 Outdoor Detailed Inspection Procedure
No
Procedure
Inspection Method
Cause
1
Wait 30 seconds over after
disconnecting the power
cable Check the outdoor
PCB.
1) Is C101(
✳✳
035
✳✳
), C103(
✳✳
052/070
✳✳
) dis-
charged?
2) Is the resistance of both terminals of
C101(
✳✳
035
✳✳
), C103(
✳✳
052/070
✳✳
) opened?
3) Is the fuse of EMI PCB normal?
4) Is the reactor wire connected?
• Over Current
• Inner short of PCB
• BLDC FAN Motor Error(
✳✳
035
✳✳
)
2
Check the outdoor unit
PCB.
1) Is R001 200ohm?
2) Does RY503(
✳✳
035
✳✳
), RY01(
✳✳
052/070
✳✳
)
operate normally?
✳✳
035
✳✳
–(IC55 & 8: 0V, 4: 5V)
✳✳
052/070
✳✳
–(IC72 & 8: 0V, 4: 5V)
3) Is the fuse normal?
• Outdoor PCB Error
• Relay(RY503–
✳✳
035
✳✳
,
RY01–
✳✳
052/
070
✳✳
) Error
• IC55 Error(
✳✳
035
✳✳
)
• IC72 Error(
✳✳
052/070
✳✳
)
3
Check the LED lighting
after power supply.
1) Normal: Red: Light On, Green: Flickering, Yellow:
Light Off?
2) Is the voltage of C101(
✳✳
035
✳✳
), C103(
✳✳
052/
070
✳✳
) 250V over?
3) Is the input of IC19 8V, and the output 5V?
4) Recheck after disassembling BLDC FAN Wire
(
✳✳
035
✳✳
)
• Inner short of outdoor PCB
• Wrong assembly of outdoor PCB
• BLDC FAN Error(
✳✳
035
✳✳
)
4
Check the condition of
indoor & outdoor connec-
tion cable.
1) Is the green LED light on once per second?
2) Is the indoor & outdoor connection cable connected
in order?
3) Is the grounding wire connected to the both of
indoor & outdoor unit?
• Wrong connection of Indoor/Outdoor
wiring
•
Wrong assembly of outdoor
communication circuit
5
Check the Comp Wire.
1) Is it connected red, blue, and yellow in order in
counter clockwise.
2) Are the valve and its installation condition good?
3) Is the installation condition of outdoor unit?
•
Wrong assembly
•
Installation condition is bad.
6
Check the BLDC Fan.
(
✳✳
035
✳✳
)
1) Is CN01 1, 3 over 250V?
2) Is CN01 3, 5 within 1V~5V?
3) Is the voltage of CN01 6 changed?
4) Is the resistance of BLDC Motor 1, 3 opened after
power off?
•
Outdoor PCB Error
• BLDC Motor Error
Troubleshooting
12-20
25888A(1)_1.indd 49
2006-04-14 ソタネト 2:26:16
Содержание UH035EAV Series
Страница 46: ...MEMO Samsung Electronics 4 27 ...
Страница 57: ...Samsung Electronics 5 11 5 3 Ass y Control Out UH035EAV DB93 03453A ...
Страница 59: ...Samsung Electronics Ass y Control Out cont UH052EAV DB93 03665D UH070EAV DB93 03665E 5 13 ...
Страница 100: ...Samsung Electronics 7 3 This Document can not be used without Samsung s authorization UH052EAV Wiring Diagram ...
Страница 101: ...7 4 Samsung Electronics This Document can not be used without Samsung s authorization UH070EAV Wiring Diagram ...
Страница 104: ...Samsung Electronics Main This Document can not be used without Samsung s authorization 8 3 Schematic Diagram ...
Страница 106: ...Samsung Electronics MEMO 8 5 ...
Страница 111: ...9 2 Refrigerating Cycle Diagram 9 5 Samsung Electronics EH035EAV UH035EAV ...
Страница 112: ...Samsung Electronics EH052EAV UH052EAV EH070EAV UH070EAV Circuit Descriptions 9 6 ...
Страница 152: ...Samsung Electronics 13 5 OUTDOOR FAN B D DIODE IPM DC_LINK CAP SMPS IGBT 13 2 2 UH052EAV Block Diagram ...
Страница 153: ...13 6 Samsung Electronics OUTDOOR FAN B D DIODE IPM DC_LINK CAP SMPS IGBT 13 2 3 UH070EAV Block Diagram ...
Страница 164: ...Samsung Electronics 14 10 MEMO ...
Страница 165: ...Samsung Electronics MEMO 14 11 ...