User Manual
53
MD
MD detects movement by each channel or all channels, and use to inform MD to user.
- Channel
It can set channel to All or 1~9CH.
- Sensitivity
In case of Sensitivity, it can set sensitivity per each channel Off, Lowest, Low, Middle, High,
and Highest.
- Area
Area sets detecting area when MD set.
In case of All set, it can select Set All, Clear All. In case of setup by each channel, it can set
to Set All, Clear All, and Select Area.
- Select Area
Select Area is available setup when it sets by channel, and it sets detecting parts of
movement stressed.
It sets movement detection area of user. There is
NTSC in 22x15pcs, PAL in 22x18pcs
partitions
and it can set the area move than 1 piece.
First setup value comes to “Select All”. If it presses “Select Area”, MD area setup window
appears.
User can setup MD area directly to screen.
Setup window appears that is divided
NTSC into 22x15 partitions and PAL into 22x18
partitions.
It indicates MD setup area in grey color. To select Setup area press “Enter” or
mouse click after selecting the area wants through direction key. After setup is completed, press
“ESC” or right mouse click to return previous menu.