Install Manual
32
as Relay out, the Output can be operated with digital I/O. Also, if Input is operated, the
emergency recording is started. Then the emergency recording starts to record with the Event
Record value.
Specification
The D-I/O specifications are as follows.
No. of inputs/outputs
12
Output type
DC 3V output
Specification
Connection method
Connect stripped wire end with 15 pin D_SUB.
Rated
current
DC
3.3 ~ 5V
D-I/O Connection
D-I/O inputs/outputs are connected shown in the following figure. Please refer to the section on
handling wiring for information about connecting and disconnecting.
D-I/O Settings
The 12 D-I/O ports are split with 6 for input and 6 for output. They can be configured under the
Event Setup menu tab.
Содержание SVR-3200
Страница 1: ...Install Manual 0 ...
Страница 51: ...Install Manual 50 Dimensions SVR 3200 SVR 1680 SVR 1660 SVR 1645 ...
Страница 52: ...Install Manual 51 SVR 960 ...
Страница 53: ...Install Manual 52 SVR 945 ...
Страница 54: ...Install Manual 53 ...