SVM will search all Station Blocks to locate the one most closely matching the
number being dialled. Station Blocks can contain up to six matching dial strings.
These strings can include any digit which can be dialled and the wildcard char-
acter “?”. Zero would match the operator’s extension.
Examples:
●
3??? – Match any four-digit number beginning with “3”.
●
411 – Match “411” only.
●
???5000 – Match any seven-digit number ending in “5000”.
●
??? – Match any three-digit number.
Prefix
The Dial Prefix instructs SVM what DTMF to dial, if any, prior to the
actual number. Prefix examples include a tie line or trunk access code. One
example is shown in the Off-Premise Station Block: ‘9' tells SVMi-4 to dial “9”
and then pause before dialling the actual telephone number.
Suffix
Enter any DTMF that must be dialled after the actual number. This will
usually be left blank but may include an account code or PBX feature code.
Beepers usually require some form of DTMF entry after the telephone number.
Transfer Controls
Simultaneous Xfers - Y/N. Set this parameter to ‘Y’ to allow
more than one port to transfer to the same station simultaneously. This applies
to blind transfer conditions only. ACDs and operator switchboards are examples
of “Yes” situations.
Programming - Page 101
Содержание SVM-400
Страница 1: ...SVMi 4 SVM 400 Voice Mail Systems Technical Manual and User Guide ...
Страница 50: ...The main screen looks like this and shows port activity and general statistics Programming Page 39 ...
Страница 62: ... G SITE INFORMATION H STATUS SCREEN Programming Page 51 ...
Страница 67: ...Programming Page 56 ...
Страница 68: ...Programming Page 57 ...
Страница 82: ...Block Tables All applications are built using blocks BYE BLOCK Programming Page 71 ...
Страница 159: ...MMC 727 DEFAULT DATA NONE RELATED ITEMS NONE Samsung Programming Programming SVMi 4 SVM 400 Manual MMCs ...
Страница 215: ...Samsung Business Communications Brookside Business Park Greengate Middleton Manchester M24 1GS ...