manualshive.com logo in svg
background image

Englis

English

 _ 3

SAFETY INFORMATION

Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be 
placed on the apparatus.

The Mains plug is used as a disconnect device and shall stay readily operable at any time.

FCC Statement

Caution :  Any changes or modifi cations in construction of this device which are not expressly approved by the 

party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

This device may not cause harmful interference, and

This device must accept any interference received, including interference that may cause undesired operation.

NOTE:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 

15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, any cause harmful interference to radio communications. However, 
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, the user 
is encouraged to try to correct the interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and receiver.

- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

- Consult the dealer or an experienced radio/TV technician for help.

8.

9.

1)

2)

Read these instructions.

Keep these instructions.

Heed all warnings.

Follow all instructions.

Do not use this apparatus near water.

Clean only with dry cloth.

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifi ers) that 
produce heat.

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one 
wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third 
prong is provided for your safety. If the provided plug does not fi t into your outlet, consult an electrician for 
replacement of the obsolete outlet.

  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the 

point where they exit from the apparatus.

  Only use attachments/accessories specifi ed by the manufacturer.

  Use only with cart, stand, tripod, bracket, or table specifi ed by the manufacturer, or sold with 
the apparatus.

  Unplug this apparatus when a card is used. Use caution when moving the cart/ apparatus 

combination to avoid injury from tip-over.

  Refer all servicing to qualifi ed service personnel. Servicing is required when the apparatus has been damaged in any 

way, such as powersupply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, 
the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

IMPORTANT SAFETY INSTRUCTIONS

Содержание SSA-R1003

Страница 1: ...RFID Reader user manual SSA R1003 SSA R1103 imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please visit our website www samsungsecurity com...

Страница 2: ...water on top of the controller Doing so may cause personal injury due to re electric shock or falling objects Do not install the unit in humid dusty or sooty locations Doing so may cause re or electr...

Страница 3: ...n the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help...

Страница 4: ...e 7 Cable Selection INSTALLATION AND EXTERNAL CONNECTION 8 8 Installation 9 Precautions on installation 10 External Connection INITIALIZATION 11 11 Basic Operations OUTPUT FORMAT 12 12 WIEGAND Output...

Страница 5: ...licable situation Green and red LED indicators and the Piezo buzzer ensure reliable and accurate operations 125KHz Proximity Reader ASK Modulation 26 bit Wiegand RS 232 Output Format Control of Extern...

Страница 6: ...ntroduction AT A GLANCE Front Rear LED Displays the system operation status using red and green indicators Buzzer Piezo buzzer Connection Cable Used to connect to the power or I O cable Fixing Hole Fi...

Страница 7: ...iegand Data 0 Output Port White Out Wiegand 1 Wiegand Data 1 Output Port Communication Brown RS 232 TX RS 232 Transmission Output Port Not used Orange NC Not Connected CABLE SELECTION Item Cable Type...

Страница 8: ...idway hole is located 1 7 4 31cm down from the upper hole If the product is already installed you can skip this step Insert the reader cables to the midway hole and x the reader module with two 6 32 o...

Страница 9: ...reader side by side or front and back If you install more than one reader side by side or front and back the read range may be reduced In this case if you present a card to one reader the other reade...

Страница 10: ...troller LED Control To control the LED indicators connect the yellow line to the output port relay of the controller Buzzer Control To control the built in buzzer connect the blue line to the output p...

Страница 11: ...function not only enables you to change the color representing Standby from red to green but it can be also applied to make various modi cations according to the different I O settings of the controll...

Страница 12: ...AND OUTPUT Timing Diagram Data Type Bit 1 Even Parity bit 2 bit 13 Bit 2 9 Facility Code 000 255 Bit 10 25 ID Number 00000 65 535 Bit 26 Odd Parity bit 14 bit 25 100us 1ms DATA 0 DATA 1 1 2 3 5V 0V 0V...

Страница 13: ...ar END 0x03H LRC Check the following settings Baud Rate 9600bps Data Bit 8 Parity Bit None Stop Bit 1 LRC This is the result of XOR operation of each byte from Start to End M Mark 1 Space 0 15V LSB 0...

Страница 14: ...ure that you are using a larger capacity adaptor than speci ed in the user manual or the catalog which should cover the rated current consumption of the reader If you are using multiple readers that a...

Страница 15: ...harm to human health or the environment To protect natural resources and to promote material reuse please separate batteries from other types of waste and recycle them through your local free battery...

Страница 16: ...00 TEL 82 70 7147 8740 60 FAX 82 31 8018 3745 SAMSUNG TECHWIN EUROPE LTD Samsung House 1000 Hillswood Drive Hillswood Business Park Chertsey Surrey UNITED KINGDOM KT16 OPS TEL 44 1932 45 5300 FAX 44 1...

Отзывы: