background image

 

SMH1713 

2/17/2012 

CN02 Pwr & Relay                                                      

1-NC 
3-NC 
5-(CN201-1) Vent High 
7-(CN201-1) Vent Low 
9-NC 
11-(CN201-1) In rush 

Main PCB 

CN201 Power                             

1-Line 1   
3-Main.  Lamp, fan 
5-Cooktop lamp  
7-Turntable                                                                        

RY204

 

Main 
Relay 

RY205       

Night            
Relay 

RY206             

Bright                   
Relay 

Door Interlock 

CN401

 

Door Connector                  

1 Door switch                                    
3 12vdc                                   
5 Hood TCO 5vdc                                
2 & 4 DC Common          

The fuse is located on the noise filter. 

1.  Disconnect power and remove grille and Assembly Control Box. 

2. 

Replace the fuse. 

3. 

When 20A fuse blows out by the operation of interlock monitor 

switch failure, replace the primary interlock switch, secondary inter-
lock switch, door sensing switch, interlock monitor switch and power 
relay. 

4. 

When the above four switches operate properly, check if any 

other part such as the control circuit board, blower motor or high 

CN701 

Membrane Sw

 

RY210

 

Vent 
High 

RY207             

 

Turntable 

RY202 

Power Low 

CN301 

Gas Sensor

 

RY211

 

Vent 
Low 

RY201

  

In Rush 

Microwave cover assembly 

The front of the top cover has flanges that must fit inside the front frame and vent, and the bottom goes above the bot-
tom cover.  Start with the left side and hold in place with one screw once engaged.  Leave the display loose so you can 
see that the right side is engaged properly.  Then mount display and the vent, ensuring the vent engages the flange. 

RY202 

Power High 

Отзывы: