Cabling for the ASM interconnect network
Depending upon the servers you have, you might need additional ASM Interconnect
modules or Category 5 or Category 3 Ethernet cables.
For the servers that do not need an ASM Interconnect module, a module is still
needed to connect the Remote Supervisor Adapter in the gateway server to the
integrated ASM processor. After you make that connection, you can connect the
servers together using their ASM interconnect ports. For additional information, see
“ASM interconnect network configuration examples” on page 48.
Connecting the ASM Interconnect module to the
SS370 : The ASM Interconnect module connects the Remote Supervisor
Adapter to the ASM interconnect network. This module must be purchased
separately. To connect the ASM interconnect module to the Remote Supervisor
Adapter, complete the following steps.
Attention:
To avoid damage to the Ethernet connector, do not plug the ASM
interconnect module into the Remote Supervisor Adapter Ethernet port.
1. Connect the ASM Interconnect module
1
to the Remote Supervisor Adapter
ASM interconnect (peer-to-peer) port
2
as shown in the following illustration.
This port is on the edge of the Remote Supervisor Adapter that is accessible
from the rear of the server and is labeled RS485.
46
User’s Guide
Содержание SMARTSERVER 370
Страница 1: ...SmartServer 370 User s Guide ...
Страница 2: ... Copyright SAMSUNG Electronics co LTD All rights reserved ...
Страница 72: ...Printed in Korea ...