Confidential and proprietary-the contents in this service guide subject to change without prior notice
Distribution, transmission, or infringement of any content or data from this document without Samsung’s written authorization is strictly prohibited.
6. Level 1 Repair
6-3. RF Calibration
6-3-1. Required items in order to calibrate RF
• Installation program: RF Calibration Program
- Daseul_Launcher_vx.x.xx.exe
- Daseul_CAL_ALL_Runtime_x.x.xxx.x.CAB
- Model File (
SM-A810F_OPEN_CALIBRATION_Ver_3.1.131.0.CAB
)
※
It is required to use the latest program.
•
SM-A810F
Mobile Phone
• R&S CMW500
• E3632A Power Supply
• GPIB Cable (2ea)
• JIG BOX (GH81-11888A)
• IF Cable (GH81-10952A)
• Adapter (GH81-11888K)
• UART Serial Cable
•
1.35Φ RF Cable (GH81-11962G 1ea)
• Table of test cables
IF Cable
GH81-10631A
GH81-10952A
GH81-11171A
11 pin
7 pin (New)
7 pin (Old)
RF Cable
(Manual)
GH81-11962D
GH81-11962G
GH81-11962C
GH81-11962F
1.35T, Short
1.35T, Long
1.6T, Short
1.6T, Long
4 Port Divider
GH81-11962A
GH81-11962B
GH81-11962E
Use /
No use
Divider Cable
50Ω terminator