Adjusting the response time (beam blocking volume)
You can use the response time adjustable volume to adjust the time between 50ms and 700ms.
Where an intruder can move across an area quickly, adjust the settings to 50ms; in a fence where unauthorized access is slow,
adjust the settings to 700ms.
Full-speed run – 50 msec
Fast walk – 150 msec
Normal walk – 250 msec
Slow walk – 550 msec
Jump over a fence or obstacle – 700 msec
Alarm Memory
Turn on the DIP switch #4 of the receiver to activate the alarm memory function.
If an alarm occurs, the detector will blink for 55 minutes after 5 minutes of standby. This can inform the patrol-guard that the
sensor has been activated when they arrive on site.
If another alarm occurs while the alarm memory is functioning by the fi rst alarm, the alarm memory will consider the second one
like it's the fi rst and extend the operation time duration accordingly.
•
•
•
•
•
M
Alarm occurrence
Memory LED
5 min
55 min (blinking)
60 min (restart operation)