6-1 Basic items for trouble shooting

Since the inverter air conditioner is equipped with Electrical control circuits at both Indoor & outdoor unit, the trouble shooting shall

be performed according to the error mode.

Inside the controller of the outdoor unit (inverter), the large capacity of electrolytic condenser so that it takes the time to discharge

after the power off since the electrical charge remains(the charging voltage DC 340V). 

Take care of the electrical shock by contact on the charging part before the discharge after the power off. (It takes approximately 

2 minutes to discharge).

1.  Is the power source proper?

The power source shall be in the range of the rated voltage ±10%. If it is out of this range, it may cause the abnormal operation.

2.

Is the connection made between the indoor and outdoor unit?

The connection between indoor and outdoor unit shall be performed with 4 wire. (connection cable of indoor and outdoor unit +

ground wire).

3.  The phenomena as follows are not out of order.

Phenomena

No

1

2

3

4

5

6

7

The operation is not done.

The wind comes out but the

heating/cooling is not performed.

The remote controller does not 

operate.

The wind volume is not adjusted.

The temperature is not set.

The operation lamp continues to be

flickering.

The immediate operation starts 

without control of remote controller

when plugged

Cause and reason

• Is the power off or the power unplugged?

• Does it stop because it is the completion time?

• Unplug and plug again the power source for 2 minutes.

• Is the filter clogged with dust or dirty?

• Is there any direct light on the outdoor unit or any obstacle against it?

• Is the selected temperature too high? 

Lower the selected temperature lower than the current one (during cooling).

• Is the selected temperature too low?

Raise the desired temperature than the current one? (during heating)

• Is the "Fan only Mode" operation?

• Is the battery run out?

• Is the battery inserted in the wrong way(+, -)?

• Is the detection part of the indoor unit blocked?

• Does it interfered with the radio of neon sign?

• Is the operation selected among one of Auto / Dry / Turbo / Sleeping?

• The temperature setting is not required since the wind volume set automatically.

• Check again at the state of Cooling / Fan only / Heating.

• Is the operation selected among the Dry / Turbo / Sleeping / Fan only Mode.

Since the temperature is automatically set, the temperature setting is not required.

• Check again at the cooling / heating state.

• The standard temperature ±2˚C during the automatic operation.

• Push the Operation / Stop button.

• Unplug and plug the power source.

• It is the case that the auto restart function works.

Auto restart function is the convenient function where the operation state is 

memorized in the Memory IC during the blackout and the operation restarts when

the power comes back.

 DB98_17175A_1  2/6/04 4:14 PM  Page 18

Содержание SH09BPH

Страница 1: ...Manual CONTENTS AIR CONDITIONER 1 Product Specifications 2 Operating Instructions 3 Disassembly and Reassembly 4 Refrigerating Cycle Diagram 5 Set Up the Model Option 6 Troubleshooting 7 Exploded Views and Parts List 8 PCB Diagram 9 Wiring Diagram ROOM AIR CONDITIONER ...

Страница 2: ...9 500 5 100 11 600 11 8 10 0 13 8 5 5 1 5 34 53 3 200 1 500 4 500 10 900 5 100 15 300 13 6 10 2 14 6 7 5 39 53 187 264 3 6 2 0 4 9 800 370 1 150 96 6 84 5 97 6 4 0 1 8 6 5 880 350 1 500 95 6 81 8 98 6 10 3 15 x 250 20 x 250 15 x 250 1 5 x 4 Single Rotary G4C090LU1ER 204CT YDK 204F8C 1 1 2µF 450V AMASS 020WTVB 1 7µF 450V UKV 18D11 1000 890 x 285 x 180 720 x 548 x 265 9 33 8 1 220 240 50 3 500 1 500...

Страница 3: ... 2 1 2 Pressure Graph SH09BPH 20 25 30 Outdoor Temp ßC 35 40 45 Pressure kgf cm 2 g 10 5 10 0 9 5 9 0 8 5 8 0 7 5 7 0 6 5 SH12BPH 20 25 30 Outdoor Temp ßC 35 40 45 Pressure kgf cm 2 g 10 5 10 0 9 5 9 0 8 5 8 0 7 5 7 0 6 5 ...

Страница 4: ...rature adjustment button UP To increase the temperature by the pressing the temperature button On Off UP DOWN Low Medium High Automatic rotated Anion button Press the button to generate ion from the air conditioner Turbo button The air conditioner cools or heats the room as quickly as possible After 30 minutes the air conditioner is reset automatically to the previous mode Mode selection button Ea...

Страница 5: ...e press the button one or more times until the required time display FUNCTION OF KEY NAMED OF KEY No 9 10 11 12 On Timer button The On Timer enables you to switch on the air conditioner automatically after a given period of time that is from 30 minutes to 24 hours To set the operating time press the button one or more times until the required time display Timer Set Cancel button After setting On T...

Страница 6: ...w temperature release Prevention against freeze 5 TURBO MODE This mode is available in AUTO COOL HEAT DRY FAN MODE When this button is pressed at first the air conditioner is operated powerful state for 30 minutes regardless of the set temperature room temperature When this button is pressed again or when the operating time is 30 minutes turbo operation mode is canceled and returned to the previou...

Страница 7: ... period of time You can set the period of time from 30 minutes to 24 hours 11 GENERATING ANION The air conditioner can generate anion with an ionizer in the indoor unit 12 SELF DIAGNOSIS 13 BUZZER SOUND Whenever the On Off button is pressed or whenever change occurs to the condition which is set up or select the compulsory operation mode buzzer is sounded beep Indoor unit room temperature sensor e...

Страница 8: ...Replace PCB Model option 2 2 1 Replace PCB model option No Yes Remove power cord Replace the PCB module Check the connection and plug in Refer to set up the Model option 15 17page Replace another PCB Does all display lamp blink ...

Страница 9: ...etach tape of Front Panel upper 3 Slide the lower Front Grille down then disassemble it by pulling it forwards 4 Open the upper Front Grille by pulling right and left sides of the Grille 5 Take the left and right Filter out 6 Loosen one of the right screw and detach the Terminal Cover 7 Detach the thermistor from the Front Grille 8 Loosen 5 fixing screws of Front Grille 9 Pull the lower left and r...

Страница 10: ...Panel Grille with the thumb to remove the hook And press the right of the upper side of the Panel Grille with the fingers And then disassemble the Panel Grille 1 Take all the connector of PCB upper side out Including Power Cord 2 Detach the outdoor unit connection wire from the Terminal Block 3 If pulling the main PCB up it will be taken out 1 Pull Tray Drain out from the Back Body ...

Страница 11: ...e 2 Detach the Connection Pipe 3 Detach the Holder Pipe at the rear side 4 Loosen 3 fixing screws of right and left side 5 Detach the Heat Exchanger from the indoor unit 1 Loosen 2 fixing screws and separate the Motor Holder 2 Loosen 1 fixing screw of Fan Motor with a M3 wrench 3 Detach the Fan Motor from the Fan 4 Detach the Fan from the left Holder Bearing ...

Страница 12: ... Loosen each 3 fixing screws on both right and left Cabinet Side edge and a fixing screw on the Cabinet Front lower to detach the Cabinet Front 2 Loosen 1 fixing screws of the Cover Valve 3 Loosen 6 fixing screws of the Cabinet Side RH 4 Loosen 2 fixing screws of the Cabinet Side LF ...

Страница 13: ...tor 1 Loosen 2 fixing screws on both sides 2 Disassemble the pipe in both inlet and outlet with welding torch 3 Detach the Heat Exchanger 1 Loosen the Terminal Cover nut to open the Terminal Cover 2 Disassemble the cloth sound felt 3 Disassemble the pipe in both inlet and outlet of the Compressor with welding torch 4 Disassemble the pipe in both inlet and outlet of the Condenser with welding torch...

Страница 14: ...cle Diagram Indoor Unit Outdoor Unit T1 T2 2 Way valve EEV 3 Way valve Gas side Heat Exchanger Evaporator Heat Exchanger Evaporator Liquid side Capillary tube 4 Way valve Cooling Heating Gas leak check point Compressor Cross fan Propeller fan ...

Страница 15: ...sh the button the display panel reads or repeatedly Setting is not required if you must a value which has a default Push the button to set the display panel to Every time you push the button the display panel reads repeatedly 3 Push the button to set the display panel to Every time you push the button the display panel reads repeatedly 4 Push the button to set the display panel to Every time you p...

Страница 16: ...ON OFF key with the direction of remote controller for set 7 8 Press button then the default value is Push the button to set the display panel to Every time you push the button the display panel reads repeatedly 10 Push the button to set the display panel to Every time you push the button the display panel reads repeatedly 9 Push the button to set the display panel to Every time you push the butto...

Страница 17: ...16 Samsung Electronics Set up the Model Option OPTION ITEMS REMOCON MODEL SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 SH09BPH SH12BPH 0 0 9 0 A 0 1 0 0 2 2 E 0 0 7 0 9 0 1 1 0 3 6 2 ...

Страница 18: ...ediate operation starts without control of remote controller when plugged Cause and reason Is the power off or the power unplugged Does it stop because it is the completion time Unplug and plug again the power source for 2 minutes Is the filter clogged with dust or dirty Is there any direct light on the outdoor unit or any obstacle against it Is the selected temperature too high Lower the selected...

Страница 19: ...r Abnormal increase of operation current Abnormal increase of OLP temperature Abnormal increase of discharge temperature Over current of IPM circuit Comp Fan Abnormal increase of heatsink temperature Fan BLCD compressor starting error Comp PCB Comp wire Outdoor unit sensor error open short deice temp sensor Temp Sensor outdoor temp sensor Temp Sensor discharge temp sensor Temp Sensor OLP temp sens...

Страница 20: ...t Discharge sensor temp trip Discharge sensor error Open Short OLP sensor error Open Short CT sensor error Unit Over Current protection Deice sensor error Open Short OLP sensor temp trip OPTION error EEPROM Compressor rotation error DC fan error SH12BWHX only DC Link voltage sensor error PFC OC error NO GAS error AC Line zero crossing error YELLOW GREEN RED LAMP of Display Monitor Description Lamp...

Страница 21: ...05 D Er 06 A E3 01 E In case of Error Code Er 09 In case of Error Code E3 01 F In case of Error Code E3 E6 H Er 17 K In case of Error Code Er 31 H Er 32 G Er 33 G Er 36 K In case of Error Code Er 37 I Er 38 K In case of Error Code Er 11 J Er 12 M Er 13 M Er 14 L In case of Error Code Er 15 N Er 18 O Check the indoor unit control board A Checking the Remocon B Check the control board and display bo...

Страница 22: ...points Step 5 Check whether the control board gets wet with dew Step 1 Dry the control board Step 6 Check whether tiny metal objects make a short fircuit on the PCB especially between pins of the surface mount IC Step 1 remove the objects Do not use splay solvent or some components may get damage by solvent 6 3 2 B C Display board and remocon check of indoor unit Check whether the connection wire ...

Страница 23: ...or occurs 1 If the cable connecting the indoor unit and outdoor unit is longer than 20m error mode may occur shorten the cable length Check of indoor unit Check whether the connection wire of the terminal block and control board of indoor unit is correct Check of outdoor unit Check whether the connection wire of the terminal block and control board of outdoor unit is correct 2 Check of power suppl...

Страница 24: ...the ambient temperature is higher than 50 C Reinstall the outdoor unit so that the good ventilation can be made If the Refrigerant is overcharged Check the amount of Refrigerant If the comp is locked Replace the comp If the comp is operating without the revolution of fan motor Check the fan motor connector replace the fan motor If the protection cover is operating with bending to the outdoor Take ...

Страница 25: ...t the revolution of fan motor Check the fan motor connector and replace the fan motor In case the parts of the control board is damaged Replace the outdoor control board 6 3 12 M Check of the comp discharge gas temperature and OLP temperature abnormal rise If the comp discharge gas temperature and OLP temperature rises higher than a certain level it protects the circuit If the comp discharge gas t...

Страница 26: ...alling leaves Take away the leaves for the good ventilation If the refrigerant is insufficient Fill up the amount of refrigerant Unit defect If the fan is locked with some object Remove the object If the comp is operationg without the revolution of fan motor Take out the protection cover Check the fan motor connector CN54 running capacitor relay RY503 and replace the fan motor 6 3 14 O Check BLDC ...

Страница 27: ...oard of outdoor units correct If it is normal replace 4 Way valve 6 3 17 R Check of outdoor unit fan motor SH12BPHX only Check whether the wire of fan motor is connected to the control board CN01 of outdoor unit Check the voltage on the control board of outdoor unit and if it is same as follows replace fan motor Input power AC178V AC264V CN01 1 3pin DC250V 10 DC370V 10 CN01 4 3pin DC15V ...

Страница 28: ...mal Abnormal if voltage does not change from 0V to 5V Normal At ambient temperature 10 C 30 C Abnormal OΩ open or short Measure resistance between red wire and each terminal Normal Approx 290Ω at ambient temperature 20 C 30 C Abnormal OΩ open or short Measure resistance between red wire and each terminal Normal Approx 110Ω at ambient temperature 20 C 30 C Abnormal OΩ open or short Diagnosis Part A...

Страница 29: ...17175A_1 2 6 04 4 14 PM Page 28 6 16 4 16 2 16 1 16 5 16 3 2 12 5 1 1 1 2 1 1 4 1 1 5 1 1 6 1 1 7 16 1 4 1 3 1 2 1 1 1 1 1 3 7 11 7 2 7 5 7 1 8 7 3 7 6 7 4 9 10 14 1 1 3 15 13 4 You can search for the updated part code number through the ITSELF URL http itself sec samsung co kr ...

Страница 30: ... Y FILTER BIO ASS Y 1 1 5 DB63 00581A COVER TERMINAL HIPS 1 1 6 DB93 02531N ASS Y REMOCON ASS Y 1 1 7 DB94 00304H ASS Y BACK BODY SUB ASS Y 1 1 7 1 DB61 01335A BACK BODY HIPS 1 1 7 2 DB63 00580A COVER IONIZER HIPS 1 1 7 3 DB91 00264A ASS Y ELECTRIC IONS ASS Y 1 1 7 4 DB39 01451C ASS Y CONNECTOR WIRE ION ASS Y 1 1 7 5 DB73 00128A RUBBER BEARING 1 1 7 6 DB94 40007A ASS Y BEARING MOTOR 1 1 8 DB94 000...

Страница 31: ...Samsung Electronics 30 7 2 Outdoor Unit 3 1 3 2 16 22 10 11 12 13 6 3 17 1 7 19 18 4 5 9 8 25 26 20 21 2 24 23 14 15 DB98_19047A 1 _2 4 21 04 2 27 PM Page 32 ...

Страница 32: ...TE B M 1 1 11 DB31 00220A MOTOR FAN YDK 020S62213 03 1 DB31 00238A MOTOR FAN SIC 52FV D828 1 1 12 DB67 00397A FAN PROPELLER 1 1 13 DB60 30004A NUT FLANGE 1 1 14 DB63 00763A GROMMET ISOLATOR NR 3 3 15 DB60 30028A NUT WASHER 3 3 16 DB96 03602A ASS Y COND ASS Y 1 1 17 DB93 02740C ASS Y CONTROL OUT SH12BPHX 1 DB93 02740D ASS Y CONTROL OUT SH09BPHX 1 18 DB63 01043A FELT COMP SIDE FELT 1 1 19 G4C090LU1E...

Страница 33: ...Samsung Electronics 32 7 3 Ass y Control In Indoor Unit SH09BPH SH12BPH DB93 02583A ...

Страница 34: ... 6001 001054 CASE CONTROL ASS Y MAIN PCB ASS Y S W DISPLAY PCB ASS Y MODULE PCB ASS Y TERMINAL BLOCK PLATE TERMINAL LOW HOLDER WIRE CLAMP SCREW MACHINE SCREW MACHINE C W MODULE C W STEP MOTOR UP DOWN SEAL SCREW MACHINE C W STEPPING MOTOR C W ION PCB HOLDER DISPLAY HALF MIRROR FAN CAPACITOR SEAL THERMISTOR THERMISTOR C W FAN_CAP POWER CORD SCREW MACHINE ABS ASS Y ASS Y ASS Y ASS Y SGCC M T1 2 HIPS ...

Страница 35: ...Samsung Electronics 34 7 4 Ass y Control Out SH09BPHX DB93 02740D SH12BPHX DB93 02740C ...

Страница 36: ...16 1 1 9 DB39 00607B CONNECTOR WIRE REACTOR UL1015 AWG 16 1 1 10 DB39 01003A CONNECTOR WIRE FAN UL1007 AWG 20 1 11 12 13 DB93 02775A ASS Y L W POWER UL1015 AWG 16 1 1 14 DB39 00649C CONNECTOR WIRE 4 WAY V V UL1015 AWG 18 1 1 15 INSULATOR MICA 1 1 16 DB65 00086A ASS Y TERMINAL BLOCK 3P 3P 1 1 17 DB61 00250A HOLDER WIRE PP 1 1 18 DB70 00465A PLATE CASE CONTROL SGCC MTO 6 1 1 19 6003 000325 SCREW TAP...

Страница 37: ...Samsung Electronics 36 8 PCB Diagram 8 1 ASS Y PCB Indoor Unit DB93 02584A TOP ...

Страница 38: ...37 Samsung Electronics PCB Diagram BOTTOM ...

Страница 39: ... DIP 8P 300MIL PLASTIC 0 3 7 1 VA71 VA72 VA73 VARISTOR INP14D561K 3 R703 R704 R METAL OXIDE S 4 7Kohm 5 2W AA TP 4x12mm 2 R701 R702 R METAL OXIDE S 47Kohm 5 3W AA TP 6x16mm 2 R601 R602 R CHIP 10Kohm 1 1 10W TP 1068 2 R504 R505 R506 R CHIP 330ohm 5 1 10W TP 1068 3 R302 R604 R605 R CHIP 470ohm 5 1 10W TP 1068 1 R201 R207 R208 R301 R CHIP 1Kohm 5 1 10W TP 1068 8 R401 R403 R607 R903 R603 R901 R CHIP 4...

Страница 40: ...A FAST ACTING CERAMIC 5 2x20mm 1 F702 FUSE RADIAL LEAD 250V 1A TIME LAG 8 5x8mm 1 CN72 CONNECTOR HEADER 1WALL 2P 1R 7 92mm STRAIGHT SN WH 1 CN73 CONNECTOR HEADER 1WALL 3P 1R 7 92mm STRAIGHT SN WH 1 CN74 CONNECTOR HEADER BOX 3P 1R 2 5mm STRAIGHT SN BLU 1 CN62 CONNECTOR HEADER BOX 5P 1R 2 5mm STRAIGHT SN 1 CN71 CONNECTOR HEADER 1WALL 2P 1R 7 92mm STRAIGHT SN BLU 1 CN42 CONNECTOR HEADER BOX 2P 1R 2mm...

Страница 41: ...40 Samsung Electronics 8 2 Ass y PCB Outdoor Unit DB93 02741D 9K DB93 02741C 12K TOP ...

Страница 42: ...305 C306 C302 C307 C CER CHIP 10nF 50V 1608 5 C653 C CERAMIC 10nF 25V 1 C702 C AL 100uF 16V 1 C902 C AL 10uF 50V 1 CN01 CONNECTOR HEADER YAW396 07V WHT 1 CN04 CONNECTOR HEADER YAW396 03AV BLU 1 CN52 CN51 CONNECTOR HEADER SMAW250 04 WHT 2 CN53 CONNECTOR HEADER SMAW250 06 WHT 1 CN701 CONNECTOR HEADER SMW200 04 NTR 1 D101 DUAL DIODE FEP30JP 1 D201 DIODE RECTIFIER US1G 400V 1 D401 D402 D403 DIODE RECT...

Страница 43: ...J 1 12W 1608 7 R306 R CHIP 560 J 1 12W 1608 1 R418 R CHIP 0 02R J 7W 1 R425 R423 R421 R CHIP 100 J 1 8W 1608 3 R459 R CHIP 47K J 1 8W 2012 1 R460 R CHIP 20K J 1 8W 2012 1 R507 R508 R CHIP 1K F 1 12W 1608 2 R510 R511 R509 R CHIP 100K J 1 12W 1608 3 R512 R CHIP 5 6K J 1 12W 1608 1 R513 R514 R529 R528 R527 R526 R530 R CHIP 10K F 1 12W 1608 15 R531 R525 R524 R522 R521 R533 R534 R535 R536 R CHIP 1M J 1...

Страница 44: ...Samsung Electronics 43 PCB Diagram BOTTOM ...

Страница 45: ... IC15 PHOTO COUPLER TLP181 1 IC31 PHOTO COUPLER TLP181 GRH 150 300 1 IC451 IC OP AMP LA6393M 1 IC55 IC56 TR ARRAY ULN2003AFW 1W 2 IC74 IC LOGIC 74HCT00D SOP 14 1 IC83 LM324 LM324 1 Q201 Q802 TR DIGITAL KRC102S 2 Q801 Q804 TR SMALL SIGNAL BC847B 2 R002 R003 R CHIP 470K F 1 2W 5025 2 R105 R CHIP 6 8K F 1 8W 2012 1 R110 R111 R451 R CHIP 180K F 6432 1W 3 R112 R113 R114 R CHIP 470K F 1 4W 3 R203 R405 R...

Страница 46: ... R554 R CHIP 470 J 1 8W 2012 1 R802 R CHIP 220 J 1 8W 2012 1 R803 R CHIP 2 2K F 6432 1W 1 R805 R CHIP 3 3K F 1 8W 2012 1 R302 R807 R CHIP 1K J 1 8W 2012 2 R103 R811 R813 R CHIP 330 J 1 8W 2012 3 R814 R CHIP 5 1K J 1 8W 2012 1 R806 R809 R901 R902 R CHIP 10K J 1 8W 2012 8 R903 R904 R905 R908 R906 R CHIP 6 8K J 1 8W 2012 1 R907 R CHIP 560 J 1 8W 2012 1 Specification Q TY Description Location No ...

Страница 47: ...B 9K 12K DB93 01368G Parts List No 1 ASS Y LED MODULE 1 SNA 2 PCB DISPLAY FR 1 T1 6 1 SNA 3 TACT SWITCH KPT 1105A TSTA 2 1 SNA 4 RESISTOR 200ohm 2W 2 SNA 5 RESISTOR 100ohm 2W 3 SNA 6 CONNECTOR WIRE 14P 1 SNA Specification Description Remark Q TY ...

Страница 48: ...01369A Parts List No 1 PCB DISPLAY FR 1 T1 6 1 SNA 2 CONNECTOR SMAW200 03P WHT 1 SNA 3 C CERAMIC CA OA 50V 102K 1 SNA 4 DIODE SWITCHING 1N4148 1 SNA 5 C CERAMIC CA OA 50V 104Z 1 SNA 6 MODULE REMOCON FRP4021 H7 7mm 1 SNA Specification Description Remark Q TY ...

Страница 49: ...48 Samsung Electronics 9 Wiring Diagram 9 1 Indoor Unit 9K 12K This Document can not be used without Samsung s authorization DB98_17175A_1 2 6 04 4 14 PM Page 49 ...

Страница 50: ...Samsung Electronics 49 9 2 Outdoor Unit 9K 12K This Document can not be used without Samsung s authorization Code No DB98 17635A DB98_19047A 1 _2 4 21 04 2 27 PM Page 50 ...

Страница 51: ...MEMO Samsung Electronics 50 ...

Страница 52: ...ICS This Service Manual is a property of Samsung Electronics Co Ltd Any unauthorized use of Manual can be punished under applicable International and or domestic law Samsung Electronics Co Ltd Printed in China ...

Отзывы: